The reliability of "Analyze" software in measuring orbital volume utilizing CT-derived data

被引:29
作者
Koppel, DA
Foy, RH
McCaul, JA
Logan, J
Hadley, DM
Ayoub, A
机构
[1] So Gen Hosp, West Scotland Reg Maxillofacial Unit, Glasgow G51 4TF, Lanark, Scotland
[2] Univ Glasgow, Glasgow Dent Hosp & Sch, Glasgow G12 8QQ, Lanark, Scotland
[3] Inst Neurol, Glasgow, Lanark, Scotland
关键词
D O I
10.1016/S1010-5182(02)00170-1
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: Craniomaxillofacial surgeons require to estimate the orbital volume in a variety of clinical situations. This paper evaluates a new method based on software analysis of computerized tomography (CT) scan data. Material and methods: Five dried skulls with prosthetic globes and periorbita were non-helically scanned in an Elscint 2400 CT scanner. Images obtained were processed using the "Analyze" software package and results compared to the volume of the intraorbital prosthesis as determined by a volume displacement gravimetric method. Results: Estimates of volume produced by the software varied from the gold standard by 0.06-50.44%, with a mean error of 8.8%. Conclusion: Despite the use of a variety of scan protocols it was not possible to obtain results with "Analyze" software which were sufficiently accurate for clinical use. (C) 2003 European Association for Cranio-Maxillofacial Surgery.
引用
收藏
页码:88 / 91
页数:4
相关论文
共 11 条
[1]   ORBITAL VOLUME MEASUREMENTS IN ENOPHTHALMOS USING 3-DIMENSIONAL CT IMAGING [J].
BITE, U ;
JACKSON, IT ;
FORBES, GS ;
GEHRING, DG .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1985, 75 (04) :502-507
[2]   ORBITAL VOLUME MEASUREMENT IN THE MANAGEMENT OF PURE BLOWOUT FRACTURES OF THE ORBITAL FLOOR [J].
CHARTERIS, DG ;
CHAN, CH ;
WHITEHOUSE, RW ;
NOBLE, JL .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1993, 77 (02) :100-102
[3]  
Cooper W C, 1985, Trans Am Ophthalmol Soc, V83, P546
[4]   STUDIES ON ENOPHTHALMOS .2. THE MEASUREMENT OF ORBITAL INJURIES AND THEIR TREATMENT BY QUANTITATIVE COMPUTED-TOMOGRAPHY [J].
MANSON, PN ;
GRIVAS, A ;
ROSENBAUM, A ;
VANNIER, M ;
ZINREICH, J ;
ILIFF, N .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1986, 77 (02) :203-214
[5]  
McGurk M, 1992, Dentomaxillofac Radiol, V21, P70
[6]   TREATMENT OF EXOPHTHALMOS [J].
PEARL, RM ;
VISTNES, L ;
TROXEL, S .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1991, 87 (02) :236-244
[7]   Prediction of late enophthalmos by volumetric analysis of orbital fractures [J].
Raskin, EM ;
Millman, AL ;
Lubkin, V ;
Della Rocca, RC ;
Lisman, RD ;
Maher, EA .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1998, 14 (01) :19-26
[8]  
ROBB R A, 1991, Australasian Physical and Engineering Sciences in Medicine, V14, P9
[9]  
Schuknecht B, 1996, NEURORADIOLOGY, V38, P470
[10]   Enucleation volume measurement [J].
Thaller, VT .
OPHTHALMIC PLASTIC AND RECONSTRUCTIVE SURGERY, 1997, 13 (01) :18-20