Intrinsic spatial resolution of semiconductor X-ray detectors: a simulation study

被引:12
作者
Hoheisel, M
Giersch, J
Bernhardt, P
机构
[1] Siemens AG, Med Solut, D-91301 Forchheim, Germany
[2] Univ Erlangen Nurnberg, Inst Phys, D-8520 Erlangen, Germany
关键词
medical X-ray imaging; detectors; absorber; photon counting; Monte Carlo simulation; modulation transfer function;
D O I
10.1016/j.nima.2004.05.077
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We have investigated the intrinsic limitation of the spatial resolution of a directly absorbing semiconductor detector. The primary interaction of an incident X-ray quantum is followed by a series of processes that generate Compton or fluorescence photons and subsequent electrons. Their ranges determine the spatial resolution of the detector, expressed in terms of the modulation transfer function. The effects of carrier transport have been neglected in this work. Monte Carlo simulations have been carried out in the 10-100 keV energy range with the program, ROSI (Roentgen Simulation), which is based on the well-established EGS4 algorithm. On a fine grid, the lateral distribution of deposited energy has been calculated in typical materials such as Se, CdTe, HgI2 and PbI2. The results can be used to either determine the point spread function of an energy-integrating detector, or to study multiple registration in adjacent pixels of photon-counting detectors. The results show that the complex absorption process determines the spatial resolution of the detector considerably. If a very high spatial resolution is required, a well-adapted semiconductor should be applied. Dependent on the energy range used, lists of favorable materials are given. At energies above 50 keV, Compton scattering reduces spatial resolution in the high frequency range. (C) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 5 条
[1]   SIGNAL AND NOISE IN MODULATION TRANSFER-FUNCTION DETERMINATIONS USING THE SLIT, WIRE, AND EDGE TECHNIQUES [J].
CUNNINGHAM, IA ;
REID, BK .
MEDICAL PHYSICS, 1992, 19 (04) :1037-1044
[2]   ROSI - an object-oriented and parallel-computing Monte Carlo simulation for X-ray imaging [J].
Giersch, J ;
Weidemann, A ;
Anton, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :151-156
[3]   Fundamental limitations imposed by x-ray interactions on the modulation transfer function of existing x-ray detectors [J].
Hajdok, G ;
Battista, J ;
Cunningham, IA .
MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 :1-15
[4]   Requirements on amorphous semiconductors for medical X-ray detectors [J].
Hoheisel, M ;
Bätz, L .
THIN SOLID FILMS, 2001, 383 (1-2) :132-136
[5]   Amorphous silicon X-ray detectors [J].
Hoheisel, M ;
Arques, M ;
Chabbal, J ;
Chaussat, C ;
Ducourant, T ;
Hahm, G ;
Horbaschek, H ;
Schulz, R ;
Spahn, M .
JOURNAL OF NON-CRYSTALLINE SOLIDS, 1998, 227 :1300-1305