Design of a Novel Flexible Capacitive Sensing Mattress for Monitoring Sleeping Respiratory

被引:14
作者
Chang, Wen-Ying [1 ]
Huang, Chien-Chun [2 ]
Chen, Chi-Chun [1 ]
Chang, Chih-Cheng [3 ]
Yang, Chin-Lung [1 ]
机构
[1] Natl Cheng Kung Univ, Dept Elect Engn, Tainan 701, Taiwan
[2] Natl Chiao Tung Univ, Biomed Elect Translat Res Ctr, Hsinchu 300, Taiwan
[3] Taipei Med Univ, Div Pulm Med, Dept Internal Med, Shuang Ho Hosp, Taipei 235, Taiwan
关键词
body movement; respiration detection; flexible projected capacitive sensing mattress; SENSOR; POLYSOMNOGRAPHY; DIAGNOSIS; NIGHT; HEARTBEAT; SYSTEM;
D O I
10.3390/s141122021
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, an algorithm to extract respiration signals using a flexible projected capacitive sensing mattress (FPCSM) designed for personal health assessment is proposed. Unlike the interfaces of conventional measurement systems for poly-somnography (PSG) and other alternative contemporary systems, the proposed FPCSM uses projected capacitive sensing capability that is not worn or attached to the body. The FPCSM is composed of a multi-electrode sensor array that can not only observe gestures and motion behaviors, but also enables the FPCSM to function as a respiration monitor during sleep using the proposed approach. To improve long-term monitoring when body movement is possible, the FPCSM enables the selection of data from the sensing array, and the FPCSM methodology selects the electrodes with the optimal signals after the application of a channel reduction algorithm that counts the reversals in the capacitive sensing signals as a quality indicator. The simple algorithm is implemented in the time domain. The FPCSM system is used in experimental tests and is simultaneously compared with a commercial PSG system for verification. Multiple synchronous measurements are performed from different locations of body contact, and parallel data sets are collected. The experimental comparison yields a correlation coefficient of 0.88 between FPCSM and PSG, demonstrating the feasibility of the system design.
引用
收藏
页码:22021 / 22038
页数:18
相关论文
共 29 条
[21]  
Silicon Lab, CHARG TIM CDC SENS T
[22]  
Silicon Lab, UND CAP SENS SIGN NO
[23]   Overnight Polysomnography versus Respiratory Polygraphy in the Diagnosis of Pediatric Obstructive Sleep Apnea [J].
Tan, Hui-Leng ;
Gozal, David ;
Ramirez, Helena Molero ;
Bandla, Hari P. R. ;
Kheirandish-Gozal, Leila .
SLEEP, 2014, 37 (02) :255-260
[24]  
Tekscan, BOD PRESS MEAS SYST
[25]   Six-Port Radar Sensor for Remote Respiration Rate and Heartbeat Vital-Sign Monitoring [J].
Vinci, Gabor ;
Lindner, Stefan ;
Barbon, Francesco ;
Mann, Sebastian ;
Hofmann, Maximilian ;
Duda, Alexander ;
Weigel, Robert ;
Koelpin, Alexander .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2013, 61 (05) :2093-2100
[26]   A differential capacitive electrical field sensor array for contactless measurement of respiratory rate [J].
Wartzek, T. ;
Weyer, S. ;
Leonhardt, S. .
PHYSIOLOGICAL MEASUREMENT, 2011, 32 (10) :1575-1590
[27]   Sleep Technologists Educational Needs Assessment: A Survey of Polysomnography, Electroneurodiagnostic Technology, and Respiratory Therapy Education Program Directors [J].
Wells, Mary Ellen ;
Vaughn, Bradley V. .
JOURNAL OF CLINICAL SLEEP MEDICINE, 2013, 9 (10) :1081-1086
[28]   A portable noncontact heartbeat and respiration monitoring system using 5-GHz radar [J].
Xiao, Yanming ;
Li, Changzhi ;
Lin, Jenshan .
IEEE SENSORS JOURNAL, 2007, 7 (7-8) :1042-1043
[29]   Development of a Respiratory Inductive Plethysmography Module Supporting Multiple Sensors for Wearable Systems [J].
Zhang, Zhengbo ;
Zheng, Jiewen ;
Wu, Hao ;
Wang, Weidong ;
Wang, Buqing ;
Liu, Hongyun .
SENSORS, 2012, 12 (10) :13167-13184