A novel application of Onyx™ monolithic column for simultaneous determination of salicylic acid and triamcinolone acetonide by sequential injection chromatography

被引:27
作者
Chocholous, Petr [1 ]
Holik, Pavel [1 ]
Satinsky, Dalibor [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Pharm, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic
关键词
sequential injection chromatography; SIC; ONYX (TM) monolithic column; salicylic acid; triamcinolone acetonide; spectrophotometric determination;
D O I
10.1016/j.talanta.2006.12.009
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel and fast simultaneous determination of triamcinolone acetonide (TCA) and salicylic acid (SA) in topical pharmaceutical formulations by sequential injection chromatography (SIC) as an alternative to classical high performance liquid chromatography (HPLC) has been developed. A recently introduced Onyx(TM) monolithic C18 (50 mm x 4.6 mm, Phenomenex(R)) with 5 mm, monolithic precolumn were used for the first time for creating sequential injection chromatography system based on a FIAlab(R) 3000 with a six-port selection valve and 5.0 mL syringe pump in study. The mobile phase used was acetonitrile/water (35:65, v/v), pH 3.3 adjusted with acetic acid at flow rate 0.9 mL min(-1) . UV detection provided by fibre-optic DAD detector was set up at 240 nm. Propylparaben was chosen as suitable internal standard (IS). There is only simple pre-adjustment of the sample of topical solution (dilution with mobile phase) so the analysis is not uselessly elongated. Parameters of the method showed good linearity in wide range, correlation coefficient >0.999; system precision (relative standard deviation, R.S.D.) in the range 0.45-1.95% at three different concentration levels, detection limits (3 sigma) 1.00 mu g mL(-1) (salicylic acid), 0.66 mu g mL(-1) (triamcinolone acetonide) and 0.33 mu g mL(-1) (propylparaben) and recovery from the pharmaceutical preparations in the range 97.50-98.94%. The chromatographic resolution between peaks of compounds was more than 4.5 and analysis time was 5.1 min under the optimal conditions. The advantages of sequential injection chromatography against classical HPLC are discussed and showing that SIC can be a method of option in many cases. (C) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:854 / 858
页数:5
相关论文
共 19 条
[1]   Fast simultaneous spectrophotometric determination of naphazoline nitrate and methylparaben by sequential injection chromatography [J].
Chocholous, Petr ;
Satinsky, Dalibor ;
Solich, Petr .
TALANTA, 2006, 70 (02) :408-413
[2]   Quantitative determination of salicylic acid and metabolites in animal tissues by liquid chromatography-tandem mass spectrometry [J].
Croubels, S ;
Maes, A ;
Baert, K ;
De Backer, P .
ANALYTICA CHIMICA ACTA, 2005, 529 (1-2) :179-187
[3]   On-line post-column photochemical derivatization in liquid chromatographic-diode-array detection analysis of binary drug mixtures [J].
DiPietra, AM ;
Andrisano, V ;
Gotti, R ;
Cavrini, V .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1996, 14 (8-10) :1191-1199
[4]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413
[5]   Coupling of monolithic columns with sequential injection technique -: A new separation approach in flow methods [J].
Huclová, J ;
Satínsky, D ;
Karlícek, R .
ANALYTICA CHIMICA ACTA, 2003, 494 (1-2) :133-140
[6]   Automation of simultaneous release tests of two substances by sequential injection chromatography coupled with Franz cell [J].
Klimundová, J. ;
Satinsky, D. ;
Sklenárová, H. ;
Solich, P. .
TALANTA, 2006, 69 (03) :730-735
[7]   Sequential injection analysis [J].
Lenehan, CE ;
Barnett, NW ;
Lewis, SW .
ANALYST, 2002, 127 (08) :997-1020
[8]   Simultaneous monitoring of aspirin, phenacetin and caffeine in compound aspirin tablets using a sequential injection drug-dissolution testing system with partial least squares calibration [J].
Liu, XZ ;
Liu, SS ;
Wu, JF ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1999, 392 (2-3) :273-281
[9]   SIMULTANEOUS MONITORING OF GLUCOSE, LACTIC-ACID AND PENICILLIN BY SEQUENTIAL INJECTION-ANALYSIS [J].
MIN, RW ;
NIELSEN, J ;
VILLADSEN, J .
ANALYTICA CHIMICA ACTA, 1995, 312 (02) :149-156
[10]   Effect of skeleton size on the performance of octadecylsilylated continuous porous silica columns in reversed-phase liquid chromatography [J].
Minakuchi, H ;
Nakanishi, K ;
Soga, N ;
Ishizuka, N ;
Tanaka, N .
JOURNAL OF CHROMATOGRAPHY A, 1997, 762 (1-2) :135-146