Effect of variability of plasma interferences on the accuracy of drug immunoassays

被引:15
作者
Ezan, E
Emmanuel, A
Valente, D
Grognet, JM
机构
[1] Commsrt. à l'Energie Atomique, Serv. de Pharmacologie et d'Immunol., Gif-sur-Yvette
[2] Serv. de Pharmacologie et d'Immunol., CEA/Saclay
关键词
drug; immunoassay; validation; plasma; interference; nomegestrol; BN; 52080;
D O I
10.1097/00007691-199704000-00017
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Most immunoassays applied to drugs in human plasma do not use an extraction of analyte. To compensate for interferences due to plasma proteins or salts, standards are prepared in drug-free plasma. Because the concentration of plasma components varies from one subject to another, it is likely that the drug-free plasma is not representative of the potential interference in each plasma. Using two immunoassays, for a steroid (nomegestrol acetate) and a heptapeptide (BN 52080), the authors have shown that tracer binding to the antibody may vary significantly between plasma from different subjects. Intersubject variability of tracer-antibody binding was 21.6% (coefficient of variation for 25 subjects) for nomegestrol acetate. When the same plasma were spiked with the steroid at a concentration corresponding to the central part of the standard curve, the recovery was between 39 and 215%. Intersubject variability in tracer binding was lower (7.7%) for the peptide immunoassay, but still affected accuracy. The authors show that this problem is common to direct immunoassays for other drugs and must be solved in assay development.
引用
收藏
页码:212 / 218
页数:7
相关论文
共 23 条
[1]   THE USE OF COMPETITIVE DISPLACEMENT AGENTS TO RESOLVE ALBUMIN-BINDING PROBLEMS OBSERVED DURING THE DEVELOPMENT OF A RADIOIMMUNOASSAY FOR ICI-215001 [J].
BALLARD, P ;
MALONE, MD ;
LAW, B .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1994, 12 (01) :47-52
[3]   APRIKALIM - RADIOIMMUNOASSAY AND PHARMACOKINETIC STUDIES IN MOUSE, MONKEY, AND DOG [J].
CHEVALIER, P ;
ROUILLARD, C ;
MONTAY, G ;
FRYDMAN, A .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1994, 83 (03) :372-378
[4]  
COLLIGNON F, 1984, EUR J NUCL MED, V9, P23
[5]   TRITON X-100 ELIMINATES PLASMA-PROTEINS INTERFERENCE IN A RADIOIMMUNOASSAY FOR LUTEINIZING-HORMONE-RELEASING HORMONE (LHRH) AND LHRH ANALOGS [J].
EZAN, E ;
DRIEU, K ;
DRAY, F .
JOURNAL OF IMMUNOLOGICAL METHODS, 1989, 122 (02) :291-296
[6]   ENZYME IMMUNOASSAYS FOR A NEW ANGIOTENSIN-CONVERTING ENZYME-INHIBITOR, ZABICIPRIL, AND ITS ACTIVE METABOLITE IN HUMAN PLASMA - APPLICATION TO PHARMACOKINETIC STUDIES [J].
EZAN, E ;
MORGE, X ;
LELIEVRE, E ;
CREMINON, C ;
PIRAUBE, C ;
GROGNET, JM .
THERAPEUTIC DRUG MONITORING, 1993, 15 (05) :448-454
[7]   ENZYME-IMMUNOASSAY FOR NOMEGESTROL ACETATE IN HUMAN PLASMA [J].
EZAN, E ;
BENECH, H ;
BUCOURT, R ;
ARDOUIN, T ;
TCHERNATINSKY, C ;
THOMAS, JL ;
PARIS, J ;
GROGNET, JM .
JOURNAL OF STEROID BIOCHEMISTRY AND MOLECULAR BIOLOGY, 1993, 46 (04) :507-514
[8]   IMMUNOMETRIC ASSAY OF BN-52080, A HEPTAPEPTIDE C-TERMINAL ANALOG OF SORBIN [J].
EZAN, E ;
TARRADE, T ;
CAZENAVE, C ;
ARDOUIN, T ;
GENET, R ;
GRASSI, J ;
GROGNET, JM ;
PRADELLES, P .
PEPTIDES, 1995, 16 (03) :449-455
[9]  
Ezan E, 1996, INT J CLIN PHARM TH, V34, P32
[10]  
GOSLING JP, 1990, CLIN CHEM, V36, P1408