Target-induced aptamer displacement on gold nanoparticles and rolling circle amplification for ultrasensitive live Salmonella typhimurium electrochemical biosensing

被引:40
作者
Ge, Chuang [1 ,2 ,3 ]
Yuan, Rui [1 ,2 ,3 ]
Yi, Lin [1 ,2 ,3 ,4 ]
Yang, Jingli [5 ]
Zhang, Haiwei [1 ,2 ,3 ]
Li, Lixian [1 ,2 ,3 ]
Nian, Weiqi [1 ,2 ,3 ]
Yi, Gang [4 ]
机构
[1] Chongqing Univ, Canc Hosp, Chongqing Key Lab Translat Res Canc Metastasis &, Chongqing 400030, Peoples R China
[2] Chongqing Canc Inst, Chongqing 400030, Peoples R China
[3] Chongqing Canc Hosp, Chongqing 400030, Peoples R China
[4] Chongqing Med Univ, Coll Lab Med, Key Lab Clin Lab Diagnost, Minist Educ China, Chongqing 400016, Peoples R China
[5] Chongqing Med Univ, Chongqing Key Lab Child Infect & Immun, China Int Sci & Technol Cooperat Base Child Dev &, Dept Neonatol,Childrens Hosp,Minist Educ,Key Lab, Chongqing 400014, Peoples R China
关键词
Salmonella typhimurium; Target-induced aptamer displacement; AuNPs assisted with RCA technology; Electrochemical biosensing; TIME MULTIPLEX PCR; RAPID DETECTION; TETRACYCLINE; ENTERITIDIS; APTASENSOR; SENSORS; OXIDE; ASSAY; ACID; MEAT;
D O I
10.1016/j.jelechem.2018.07.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Salmonella typhimurium (S. typhimurium) infection disease is harm to public through food have become a lifethreatening problem stresses an urgent need for development of rapid, robust and cost-effective alternative technology to help control the spread of S. typhimurium. Herein, a simple and facile aptasensor has been developed for ultrasensitive determination of live S. typhimurium by combining target-induced aptamer displacement on gold nanoparticles (AuNPs) deposited electrode with rolling circle amplification (RCA). The heterogeneous recognition and specific binding of target S. typhimurium with aptamer, releasing the primer binding part, leading to anchoring multiple circular templates on the aptasensor surface. Then, the RCA reaction was initiated to produce massive long DNA molecules with multiple tandem-repeat sequences. These RCA products could hybridize with the biotinylated detection probes for enzyme-amplified electrochemical readout on the surface of the aptasensor. The designed electrochemical aptasensor showed very high sensitivity for S. typhimurium down to 16 CFU mL(-1) with a wide linear detection range of 20 to 2 x 10(8) CFU mL(-1), and exhibited remarkable signal amplification performance, acceptable reproducibility and low matrix effect This proposed strategy presented a simple and facile platform towards ultrasensitive and handy bacterial detection, which would become an effective tool for microorganism detection in food safety, clinical diagnostics and even biological threats monitoring.
引用
收藏
页码:174 / 180
页数:7
相关论文
共 39 条
[1]   Rolling circle amplification: a versatile tool for chemical biology, materials science and medicine [J].
Ali, M. Monsur ;
Li, Feng ;
Zhang, Zhiqing ;
Zhang, Kaixiang ;
Kang, Dong-Ku ;
Ankrum, James A. ;
Le, X. Chris ;
Zhao, Weian .
CHEMICAL SOCIETY REVIEWS, 2014, 43 (10) :3324-3341
[2]   Enzyme-linked imunoassays for the detection of Listeria sp and Salmonella sp in sausage: A comparison with conventional methods [J].
Benetti, T. M. ;
Monteiro, C. L. B. ;
Beux, M. R. ;
Abrahao, W. M. .
BRAZILIAN JOURNAL OF MICROBIOLOGY, 2013, 44 (03) :791-794
[3]  
Benvidi A., 2015, ELECTROANAL CHEM, V736, P22
[4]   Designing and fabrication of a novel sensitive electrochemical aptasensor based on poly (L-glutamic acid)/MWCNTs modified glassy carbon electrode for determination of tetracycline [J].
Benvidi, Ali ;
Yazdanparast, Samira ;
Rezaeinasab, Masoud ;
Tezerjani, Marzieh Dehghan ;
Abbasi, Saleheh .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 808 :311-320
[5]   An aptasensor for tetracycline using a glassy carbon modified with nanosheets of graphene oxide [J].
Benvidi, Ali ;
Tezerjani, Marzieh Dehghan ;
Moshtaghiun, Seyed Mohammad ;
Mazloum-Ardakani, Mohammad .
MICROCHIMICA ACTA, 2016, 183 (05) :1797-1804
[6]   Ultrasensitive DNA sensor based on gold nanoparticles/reduced graphene oxide/glassy carbon electrode [J].
Benyidi, Ali ;
Firouzabadi, Afsaneh Dehghani ;
Moshtaghiun, Seyed Mohammad ;
Mazloum-Ardakani, Mohammad ;
Tezerjani, Marzieh Dehghan .
ANALYTICAL BIOCHEMISTRY, 2015, 484 :24-30
[7]   Epidemiology, Clinical Presentation, Laboratory Diagnosis, Antimicrobial Resistance, and Antimicrobial Management of Invasive Salmonella Infections [J].
Crump, John A. ;
Sjoelund-Karlsson, Maria ;
Gordon, Melita A. ;
Parry, Christopher M. .
CLINICAL MICROBIOLOGY REVIEWS, 2015, 28 (04) :901-937
[8]  
D'Aoust JY, 2007, FOOD MICROBIOLOGY: FUNDAMENTALS AND FRONTIERS, THIRD EDITION, P187
[9]   Applications of a DNA-electrochemical biosensor [J].
Diculescu, Victor Constantin ;
Chiorcea-Paquim, Ana-Maria ;
Oliveira-Brett, Ana Maria .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 79 :23-36
[10]   Iron oxide/gold core/shell nanomagnetic probes and CdS biolabels for amplified electrochemical immunosensing of Salmonella typhimurium [J].
Freitas, M. ;
Viswanathan, S. ;
Nouws, H. P. A. ;
Oliveira, M. B. P. P. ;
Delerue-Matos, C. .
BIOSENSORS & BIOELECTRONICS, 2014, 51 :195-200