Micro X-ray tomographic imaging of porous media

被引:0
|
作者
Williams, R. A. [1 ]
Jia, X. [1 ]
Selomulya, C. [2 ]
机构
[1] Univ Leeds, Sch Proc Environm & Mat Engn, IPSE, Leeds LS2 9JT, W Yorkshire, England
[2] Monash Univ, Dept Chem Engn, Clayton, Vic 3800, Australia
关键词
X-ray microtomography; imaging; porous media; flow;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Do not X-ray Microtomography (XMT) is a relatively new technology for measuring and characterising structures of materials at micron scales. It operates on the same principles as hospital CT scanners, but with much higher spatial resolution. The enhanced spatial resolution, portability and affordability, and the non-destructive nature of the measurement technique, are making XMT an increasingly popular means for scientists and engineers to measure or characterise structures of various materials in full 3D with unprecedented level of details. This paper reports on use of two such scanners and their application to porous media imaging.
引用
收藏
页码:3 / +
页数:3
相关论文
共 50 条
  • [21] Field emission arrays for tomographic medical x-ray imaging
    Schwoebel, P. R.
    Holland, C. E.
    Spindt, C. A.
    2006 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE HELD JOINTLY WITH 2006 IEEE INTERNATIONAL VACUUM ELECTRON SOURCES, 2006, : 511 - 511
  • [22] PERFORMANCE OF X-RAY COMPUTED TOMOGRAPHIC IMAGING-SYSTEMS
    SIVERS, EA
    SILVER, MD
    MATERIALS EVALUATION, 1990, 48 (06) : 706 - 713
  • [23] X-ray tomographic imaging of crystal structure at the atomic level
    Korecki, P
    Tolkiehn, M
    Novikov, DV
    Materlik, G
    Szymonski, M
    PHYSICAL REVIEW LETTERS, 2006, 96 (03)
  • [24] Influence of the X-Ray Spectrum on the Tomographic Reconstruction of Porous Ceramic Membranes
    Grigoriev, M., V
    Krivonosov, Yu S.
    Buzmakov, A., V
    Chukalina, M., V
    Asadchikov, V. E.
    Uvarov, V., I
    CRYSTALLOGRAPHY REPORTS, 2021, 66 (06) : 1100 - 1108
  • [25] Influence of the X-Ray Spectrum on the Tomographic Reconstruction of Porous Ceramic Membranes
    M. V. Grigoriev
    Yu. S. Krivonosov
    A. V. Buzmakov
    M. V. Chukalina
    V. E. Asadchikov
    V. I. Uvarov
    Crystallography Reports, 2021, 66 : 1100 - 1108
  • [26] X-ray imaging microscopy using a micro capillary X-ray refractive lens
    Kohmura, Y
    Okada, K
    Awaji, M
    Suzuki, Y
    Ishikawa, T
    Dudchik, YI
    Kolchevsky, NN
    Komarov, FF
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 566 - 570
  • [27] Application of synchrotron X-ray micro tomographic microscopy at low temperature
    Murshed, Mohammad M.
    Enzmann, Frieder
    Miedaner, Markus M.
    Szeder, Thore
    Huthwelker, Thomas
    Stampanoni, Marco
    Kersten, Michael
    ACTA CRYSTALLOGRAPHICA A-FOUNDATION AND ADVANCES, 2008, 64 : C183 - C183
  • [28] FLUID SATURATION IN POROUS MEDIA BY X-RAY TECHNIQUE
    LAIRD, ADK
    PUTNAM, JA
    TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1951, 192 : 275 - 284
  • [29] X-ray micro-imaging by capillary optics
    Hampai, Dariush
    Dabagov, Sultan B.
    Cappuccio, Giorgio
    Cibin, Giannantonio
    Sessa, Vito
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (11-12) : 1180 - 1184
  • [30] Towards multiscale X-ray tomographic imaging in membrane science - A perspective
    Rudolph-Schopping, Gregor
    Larsson, Emanuel
    Pingel, Torben Nilsson
    Guizar-Sicairos, Manuel
    Villanueva-Perez, Pablo
    Hall, Stephen
    Lipnizki, Frank
    JOURNAL OF MEMBRANE SCIENCE, 2024, 690