Fault detection of plasma etchers using optical emission spectra

被引:99
作者
Yue, HH [1 ]
Qin, SJ
Markle, RJ
Nauert, C
Gatto, M
机构
[1] Tokyo Elect Amer Inc, Austin, TX 78741 USA
[2] Univ Texas, Dept Chem Engn, Austin, TX 78712 USA
[3] Adv Micro Devices Inc, Austin, TX 78741 USA
基金
美国国家科学基金会;
关键词
D O I
10.1109/66.857948
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The objective of this paper is to investigate the suitability of using optical emission spectroscopy (OES) for the fault detection and classification of plasma etchers. The OES sensor system used in this study can collect spectra at up to 512 different wavelengths, Multiple scans of the spectra are taken from a wafer, and the spectra data are available for multiple wafers, As a result, the amount of the OES data is typically large, This poses a difficulty in extracting relevant information for fault detection and classification, In this paper, we propose the use of multiway principal component analysis (PCA) to analyze the sensitivity of the multiple scans within a wafer with respect to typical faults such as etch stop, which is a fault that occurs when the polymer deposition rate is larger than the etch rate, Several PCA-based schemes are tested for the purpose of fault detection and wavelength selection, A sphere criterion is proposed for wavelength selection and compared with an existing method in the literature. To construct the final monitoring model, the OES data of selected wavelengths are properly scaled to calculate fault detection indices, Reduction in the number of wavelengths implies reduced cost for implementing the fault detection system. All experiments are conducted on an Applied Materials 5300 oxide etcher at Advanced Micro Devices (AMD) in Austin, TX.
引用
收藏
页码:374 / 385
页数:12
相关论文
共 23 条
[1]  
BUTLER SW, 1995, P WORKSH IND APPL PL
[2]  
BUTLER SW, 1996, CHEM PROCESS CONTR, V5, P133
[3]   The measured performance of personal computer operating systems [J].
Chen, JB ;
Endo, Y ;
Chan, K ;
Mazieres, D ;
Dias, A ;
Seltzer, M ;
Smith, MD .
ACM TRANSACTIONS ON COMPUTER SYSTEMS, 1996, 14 (01) :3-40
[4]  
CHENG Y, 1997, P ADCHEM BANFF CAN J
[5]  
GALLAGHER NB, 1997, P ADCHEM 97 BANFF CA, P78
[6]   ANALYSIS OF MULTI-WAY (MULTI-MODE) DATA [J].
GELADI, P .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1989, 7 (1-2) :11-30
[7]   CONTROL PROCEDURES FOR RESIDUALS ASSOCIATED WITH PRINCIPAL COMPONENT ANALYSIS [J].
JACKSON, JE ;
MUDHOLKAR, GS .
TECHNOMETRICS, 1979, 21 (03) :341-349
[8]  
Jackson JE, 1991, A user's guide to principal components
[9]  
Jollife IT., 1973, APPL STATIST, V22, P21, DOI [10.2307/2346300, DOI 10.2307/2346300]
[10]  
JOLLIFFE IT, 1972, J ROY STAT SOC C-APP, V21, P160