Thermodilution cardiac output - are three injections enough?

被引:44
作者
Nilsson, LB
Nilsson, JC
Skovgaard, LT
Berthelsen, PG
机构
[1] Gentofte Univ Hosp, Dept Anesthesiol, Copenhagen, Denmark
[2] Univ Copenhagen, Dept Biostat, Copenhagen, Denmark
关键词
bolus thermodilution cardiac output; cardiac output; coefficient of variation; hemodynamics; iced injectate; number of injections; pulmonary artery catheter; sample size; statistical data analysis; Swan-Ganz;
D O I
10.1111/j.1399-6576.2004.00514.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Bolus thermodilution cardiac output measurements have been a mainstay in clinical monitoring of critically ill patients for more than 30 years. Usually the results of an arbitrarily chosen number (1-6) of thermal indicator injections are averaged to increase the reliability of the measurement. The number of injections needed to achieve a given level of precision has, however, not previously been systematically investigated. Methods and results: In 80 hemodynamically stable patients cardiac output was determined as the average of eight injections of 10 ml of iced saline. From the 638 measurements we examined the relationship between the number of thermal indicator injections and the precision of the resulting cardiac output estimate. Furthermore, the association between the number of injections and the least detectable difference among two sets of measurements was established. Conclusion: The current study shows that one needs to average the results of four injections to be 95% confident that the result is within 5% of the 'true' cardiac output and that two series of four measurements have to differ by at least 7% before one can be sure (95%) that a change in cardiac function has taken place.
引用
收藏
页码:1322 / 1327
页数:6
相关论文
共 17 条
[1]  
Am Soc Anesthesiologists Task Forc, 2003, ANESTHESIOLOGY, V99, P988
[2]   Thermodilution cardiac output - Cold vs. room temperature injectate and the importance of measuring the injectate temperature in the right atrium [J].
Berthelsen, PG ;
Eldrup, N ;
Nilsson, LB ;
Rasmussen, JP .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2002, 46 (09) :1103-1110
[3]  
CULLAGH MC, 1983, GEN LINEAR MODELS, pCH8
[4]   MEASUREMENT OF CARDIAC OUTPUT IN ANAESTHETIZED ANIMALS BY A THERMO-DILUTION METHOD [J].
FEGLER, G .
QUARTERLY JOURNAL OF EXPERIMENTAL PHYSIOLOGY AND COGNATE MEDICAL SCIENCES, 1954, 39 (03) :153-164
[5]   NEW TECHNIQUE FOR MEASUREMENT OF CARDIAC OUTPUT BY THERMODILUTION IN MAN [J].
GANZ, W ;
DONOSO, R ;
MARCUS, HS ;
FORRESTER, JS ;
SWAN, HJC .
AMERICAN JOURNAL OF CARDIOLOGY, 1971, 27 (04) :392-+
[6]   Intensive care physicians' insufficient knowledge of right-heart catheterization at the bedside: Time to act? [J].
Gnaegi, A ;
Feihl, F ;
Perret, C .
CRITICAL CARE MEDICINE, 1997, 25 (02) :213-220
[7]   A MULTICENTER STUDY OF PHYSICIANS KNOWLEDGE OF THE PULMONARY-ARTERY CATHETER [J].
IBERTI, TJ ;
FISCHER, EP ;
LEIBOWITZ, AB ;
PANACEK, EA ;
SILVERSTEIN, JH ;
ALBERTSON, TE .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1990, 264 (22) :2928-2932
[8]   Overestimation of pulmonary artery occlusion pressure in pulmonary hypertension due to partial occlusion [J].
Leatherman, JW ;
Shapiro, RS .
CRITICAL CARE MEDICINE, 2003, 31 (01) :93-97
[9]   MISINTERPRETATION OF PRESSURE MEASUREMENTS FROM THE PULMONARY-ARTERY CATHETER [J].
NADEAU, S ;
NOBLE, WH .
CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1986, 33 (03) :352-363
[10]   Lack of agreement between thermodilution and carbon dioxide-rebreathing cardiac output [J].
Nilsson, LB ;
Eldrup, N ;
Berthelsen, PG .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2001, 45 (06) :680-685