Treatment outcomes of unstable proximal phalangeal head fractures of the finger in children

被引:6
作者
Bergeron, L [1 ]
Gagnon, I [1 ]
l'Écuyer, C [1 ]
Caouette-Laberge, L [1 ]
机构
[1] Univ Montreal, Hop St Justine, Div Plast Surg, Montreal, PQ H3C 3J7, Canada
关键词
finger injuries; fractures; traction; proximal interphalangeal joint; children;
D O I
10.1097/01.sap.0000141945.03201.c9
中图分类号
R61 [外科手术学];
学科分类号
摘要
The authors reviewed 37 children presenting with closed, unstable fractures of the proximal phalangeal head. Fractures were classified as intra-articular (n = 15), including 14 unicondylar and 1 bicondylar, or extra-articular (n = 22), including 20 subcondylar and 2 comminuted subcondylar. Eighteen patients underwent closed reduction with K-wire fixation (n = 11) or dynamic skeletal traction (n = 7). Nineteen patients underwent open reduction with K-wire fixation (n = 14) or miniscrews (n = 5). Results were considered excellent when the active range of motion (ROM) of the proximal interphalangeal joint was greater than or equal to 90degrees (n = 26); fair, active ROM, 70 to 89degrees (n = 6); and poor, active ROM < 70 degrees (n = 5). The intra-articular fractures were rated 9 excellent, 5 fair, and 1 poor. The extra-articular fractures were rated 17 excellent, 1 fair, and 4 poor. The 18 closed reductions, K-wire fixation (n = 11) and traction (n = 7), were rated 16 excellent and 2 fair. The 19 open reductions, K-wire fixation (n = 14) and miniscrew fixation (n = 5), were rated 10 excellent, 4 fair, and 5 poor. Closed reduction showed better results than open reduction. Dynamic skeletal traction proved to be simple and effective in treating these injuries.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 17 条
[1]   FRACTURES OF THE PHALANGES OF THE HAND IN CHILDREN [J].
BARTON, NJ .
HAND, 1979, 11 (02) :134-143
[2]  
Blazar P E, 2000, J Am Acad Orthop Surg, V8, P383
[3]   Treatment of complex interphalangeal joint fractures with dynamic external traction: A series of 20 cases [J].
Duteille, F ;
Pasquier, P ;
Lim, A ;
Dautel, G .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2003, 111 (05) :1623-1629
[4]   FRACTURES OF THE PHALANGES - RESULTS OF INTERNAL-FIXATION USING 1.5MM AND 2MM AO SCREWS [J].
FORD, DJ ;
ELHADIDI, S ;
LUNN, PG ;
BURKE, FD .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1987, 12B (01) :28-33
[5]  
FREELAND AE, 1994, HAND CLIN, V10, P239
[6]  
KEARNEY LM, 1994, HAND CLIN, V10, P199
[7]  
LEIBOVIC SJ, 1994, HAND CLIN, V10, P169
[8]  
LEONARD MH, 1970, CLIN ORTHOP RELAT R, P160
[9]  
London P S, 1971, Hand, V3, P155, DOI 10.1016/0072-968X(71)90035-0
[10]   DYNAMIC DIGITAL TRACTION FOR UNSTABLE COMMINUTED INTRAARTICULAR FRACTURE-DISLOCATIONS OF THE PROXIMAL INTERPHALANGEAL JOINT [J].
MORGAN, JP ;
GORDON, DA ;
KLUG, MS ;
PERRY, PE ;
BARRE, PS .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (04) :565-573