MRT of the eye: Normal anatomy and detection of minute lesions via a high-resolution surface coil

被引:10
作者
Hosten, N
Lemke, A
Sander, B
Requardt, H
Wassmuth, R
Maurer, J
Anders, N
Felix, R
机构
[1] SIEMENS AG,W-8520 ERLANGEN,GERMANY
[2] FREE UNIV BERLIN,KLINIKUM RUDOLF VIRCHOW,AUGENKLIN & POLIKLIN,W-1000 BERLIN,GERMANY
来源
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN | 1996年 / 164卷 / 02期
关键词
eye; magnetic resonance imaging; high-resolution surface coil;
D O I
10.1055/s-2007-1015624
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: A new high-resolution surface coil for MRI of the eye was evaluated with regard to practicability, image quality and sensitivity for small lesions. Material and methods: 48 patients in whom a space-occupying lesion of the eye or orbit was suspected were examined (1.5 T tomograph, 5 cm surface coil, T-1- and T-2-weighted spin-echo sequences, the former before and after i.v. gadolinium DTPA). Results: 45/48 patients tolerated MR with the high-resolution surface coil. No adverse effects were experienced. by the patients. In 11/48 patients a space occupying lesion of the eye was detected (melanoma, 5; metastases, 2; haemorrhage, 1; malformation, hamartoma and scarring after melanoma, one each). The smallest detectable lesion had a thickness of < 1 mm. Conclusion: First experiences with the high-resolution surface coil indicate that this device is suited for detection of very small lesions of the eye.
引用
收藏
页码:126 / 131
页数:6
相关论文
共 11 条
[1]   HIGH-RESOLUTION MR IMAGING OF THE WRIST AND EYE WITH SHORT TR, SHORT TE, AND PARTIAL-ECHO ACQUISITION [J].
FOO, TKF ;
SHELLOCK, FG ;
HAYES, CE ;
SCHENCK, JF ;
SLAYMAN, BE .
RADIOLOGY, 1992, 183 (01) :277-281
[2]   OPENING OF BLOOD OCULAR BARRIER DEMONSTRATED BY CONTRAST-ENHANCED MR IMAGING [J].
FRANK, JA ;
DWYER, AJ ;
GIRTON, M ;
KNOP, RH ;
SANK, VJ ;
GANSOW, OA ;
MAGERSTADT, M ;
BRECHBIEL, M ;
DOPPMAN, JL .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (06) :912-916
[3]  
HAIK BG, 1985, OPHTHALMOLOGY, V92, P1143
[4]  
HAIK BG, 1985, OPHTHALMOLOGY, V92, P1133
[5]   MALIGNANT UVEAL MELANOMA AND SIMULATING LESIONS - MR IMAGING EVALUATION [J].
MAFEE, MF ;
PEYMAN, GA ;
GRISOLANO, JE ;
FLETCHER, ME ;
SPIGOS, DG ;
WEHRLI, FW ;
RASOULI, F ;
CAPEK, V .
RADIOLOGY, 1986, 160 (03) :773-780
[6]   INDICATIONS FOR APPLICATION OF A HIGH-RESOLUTION COIL IN MR TOMOGRAPHY [J].
MAURER, J ;
REQUARDT, H ;
MULLER, F ;
STEINKAMP, HJ ;
HOSTEN, N ;
LANGER, R ;
FELIX, R .
FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NEUEN BILDGEBENDEN VERFAHREN, 1994, 160 (04) :353-360
[7]   HIGH-RESOLUTION MAGNETIC-RESONANCE IN CLINICAL IMAGE SYSTEM [J].
MAURER, J ;
REQUARDT, H ;
MULLER, FH ;
BOCK, JC ;
FELIX, R .
LANCET, 1993, 342 (8866) :310-310
[8]   INTRAOCULAR TUMORS - EVALUATION WITH MR IMAGING [J].
PEYSTER, RG ;
AUGSBURGER, JJ ;
SHIELDS, JA ;
HERSHEY, BL ;
EAGLE, R ;
HASKIN, ME .
RADIOLOGY, 1988, 168 (03) :773-779
[9]   INCREASED CORNEAL TEMPERATURE CAUSED BY MR IMAGING OF THE EYE WITH A DEDICATED LOCAL COIL [J].
SHELLOCK, FG ;
SCHATZ, CJ .
RADIOLOGY, 1992, 185 (03) :697-699
[10]   SHORTCOMINGS AND PITFALLS OF OCULAR MRI [J].
WILMS, G ;
MARCHAL, G ;
VANFRAEYENHOVEN, L ;
DEMAEREL, P ;
VANHECKE, P ;
BAERT, AL ;
DRALANDS, G .
NEURORADIOLOGY, 1991, 33 (04) :320-325