Glucose-sensitive nanofiber scaffolds with an improved sensing design for physiological conditions

被引:20
作者
Balaconis, Mary K. [1 ]
Luo, Yi [2 ]
Clark, Heather A. [2 ]
机构
[1] Dept Bioengn, Berkeley, CA USA
[2] Northeastern Univ, Dept Pharmaceut Sci, Boston, MA 02115 USA
关键词
BORONATE AFFINITY-CHROMATOGRAPHY; ION-SELECTIVE ELECTRODES; BULK OPTODES; PHOTONIC CRYSTAL; SENSOR; ACID; PH; NANOSENSORS; MICROGELS; MEMBRANE;
D O I
10.1039/c4an01775g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Continuous physiological monitoring of electrolytes and small molecules such as glucose, creatinine, and urea is currently unavailable but achieving such a capability would be a major milestone for personalized medicine. Optode-based nanosensors are an appealing analytical platform for designing in vivo monitoring systems. In addition to the necessary analytical performance, such nanosensors must also be biocompatible and remain immobile at the implantation site. Blood glucose in particular remains a difficult but high-value analyte to monitor continuously. Previously, we developed glucose-sensitive nanosensors that measure glucose by a competitive binding mechanism between glucose and a fluorescent dye to 4-carboxy-3-fluorophenyl boronic acid. To improve the sensitivity and residency time of our reported sensors, we present here a series of new derivatives of 4-carboxy-3-fluorophenyl boronic acid that we screened in a macrosensor format before translating into a nanofiber format with electrospinning. The lead candidate was then implanted subdermally and its residency time was compared to spherical nanosensor analogues. The nanofiber scaffolds were markedly more stable at the implantation site whereas spherical nanosensors diffused away within three hours. Based on the enhanced sensitivity of the new boronic acids and the residency time of nanofibers, this sensor configuration is an important step towards continuous monitoring of glucose and other analytes.
引用
收藏
页码:716 / 723
页数:8
相关论文
共 35 条
[1]   Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid [J].
Alexeev, VL ;
Das, S ;
Finegold, DN ;
Asher, SA .
CLINICAL CHEMISTRY, 2004, 50 (12) :2353-2360
[2]   High ionic strength glucose-sensing photonic crystal [J].
Alexeev, VL ;
Sharma, AC ;
Goponenko, AV ;
Das, S ;
Lednev, IK ;
Wilcox, CS ;
Finegold, DN ;
Asher, SA .
ANALYTICAL CHEMISTRY, 2003, 75 (10) :2316-2323
[3]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[4]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[5]  
Balaconis Mary K, 2013, J Diabetes Sci Technol, V7, P53
[6]  
Balaconis Mary K, 2011, J Diabetes Sci Technol, V5, P68
[7]   Fluorescent Nano-Optodes for Glucose Detection [J].
Billingsley, Kelvin ;
Balaconis, Mary K. ;
Dubach, J. Matthew ;
Zhang, Ning ;
Lim, Ed ;
Francis, Kevin P. ;
Clark, Heather A. .
ANALYTICAL CHEMISTRY, 2010, 82 (09) :3707-3713
[8]   Timing of changes in interstitial and venous blood glucose measured with a continuous subcutaneous glucose sensor [J].
Boyne, MS ;
Silver, DM ;
Kaplan, J ;
Saudek, CD .
DIABETES, 2003, 52 (11) :2790-2794
[9]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[10]   Phosphorescent Nanosensors for in Vivo Tracking of Histamine Levels [J].
Cash, Kevin J. ;
Clark, Heather A. .
ANALYTICAL CHEMISTRY, 2013, 85 (13) :6312-6318