Smart pumpless loop for micro-channel electronic cooling using flat and enhanced surfaces

被引:68
作者
Mukherjee, S [1 ]
Mudawar, I [1 ]
机构
[1] Purdue Univ, Int Elect Cooling Alliance, W Lafayette, IN 47907 USA
来源
IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES | 2003年 / 26卷 / 01期
关键词
boiling; critical heat flux; high heat flux; microchannel; passive cooling; phase change; pumpless loop; pressure drop;
D O I
10.1109/TCAPT.2003.811478
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Two-phase cooling of a square simulated electronic device surface of 21.3 mm side was successfully carried out without the need for a pump. This smart, passive cooling system incorporates a self-enhancing and self-sustaining mechanism, wherein the system inherently enhances its cooling capacity by increasing the velocity of the two-phase mixture along the boiling surface when an increase in heat flux is sensed. Other practical attributes of this pumpless loop are small liquid inventory requirements and absence of the incipient boiling temperature drop. It is shown small surface tension and contact angle render dielectric coolants such as FC-72 ideally suited for flow in narrow gaps. These unique properties are responsible for very small bubble size, precluding any appreciable blockage of the replenishment liquid flow even in narrow gaps. Critical heat flux (CHF) was found to generally increase with decreasing boiler gap. CHF for flat, micro-channel (with 0.2 mm rectangular fins) and mini-channel (with 1.98 mm rectangular fins) surfaces was 4.5, 5.9, and 5.7 times greater than for pool boiling from a flat surface for corresponding gaps. A pressure drop model was formulated to predict coolant mass flow rate, boiling surface inlet and exit velocities, and pressure drop components throughout the loop. The model predictions illustrate the pumpless loop's self-sustaining and self-enhancing attributes, and relate CHF trends to those of the two-phase mixture acceleration along the boiling surface.
引用
收藏
页码:99 / 109
页数:11
相关论文
共 17 条
[1]   Microelectronic Cooling by Enhanced Pool Boiling of a Dielectric Fluorocarbon Liquid [J].
Anderson, T. M. ;
Mudawar, I. .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1989, 111 (1-4) :752-759
[2]  
Bowers M. B., 1994, Transactions of the ASME. Journal of Electronic Packaging, V116, P290, DOI 10.1115/1.2905700
[3]  
Bowers M.B., 1994, Two-phase electronic cooling using mini-channel and micro-channel heat sinks: Part 2-Flow rate and pressure drop constraints
[4]   HIGH-FLUX BOILING IN LOW-FLOW RATE, LOW-PRESSURE DROP MINI-CHANNEL AND MICROCHANNEL HEAT SINKS [J].
BOWERS, MB ;
MUDAWAR, I .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (02) :321-332
[5]  
COLLIER JG, 1994, CONVECTIVE BOILING C, P46
[6]  
Fritz W, 1935, PHYS Z, V36, P379
[7]  
INCROPERA FP, 1996, FUNDAMENTALS HEAT MA, P460
[8]   SATURATED BOILING HEAT TRANSFER IN NARROW SPACES [J].
ISHIBASHI, E ;
NISHIKAWA, K .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1969, 12 (08) :863-+
[9]  
MADDOX DE, 1989, ASME, V111, P1045
[10]   CHARACTERISTIC OF HEAT-TRANSFER ENHANCEMENT DUE TO BUBBLES PASSING THROUGH A NARROW VERTICAL CHANNEL [J].
MONDE, M .