Modified microelectrodes and multivariate calibration for flow injection amperometric simultaneous determination of ascorbic acid, dopamine, epinephrine and dipyrone

被引:84
作者
Matos, RC
Angnes, L
Araújo, MCU
Saldanha, TCB
机构
[1] Univ Sao Paulo, Inst Quim, BR-05508900 Sao Paulo, Brazil
[2] Univ Fed Paraiba, CCEN, Dept Quim, BR-58059900 Joao Pessoa, Paraiba, Brazil
关键词
D O I
10.1039/b004805o
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Flow injection amperometric quantification of ascorbic acid (AA), dopamine (DA), epinephrine (EP) and dipyrone (DI) in mixtures (in the mug g(-1) range) was successfully performed by using an array of microelectrodes with units modified by the electrodeposition of different noble metals, together with multivariate calibration analysis. The four groups of microelectrodes utilized included a pure gold electrode and electrodes modified by electrodeposition of platinum, palladium or a mixture of platinum + palladium. The array of microelectrodes was inserted in a flow cell and the amperometric data acquisition was performed with a four-channel potentiostat. The analysis of the resulting signals was carried out by a multivariate calibration method, using a group of 16 standard mixtures selected by a two-level factorial design. The analysis of synthetic samples and pharmaceutical compounds containing AA and DI led to very similar values to those obtained by the classical iodimetric analysis. The average absolute errors (in mug g(-1)) calculated for each analyte were 0.3, 0.2, 0.4 and 0.4 for AA, DA, EP and DI, respectively.
引用
收藏
页码:2011 / 2015
页数:5
相关论文
共 36 条
  • [1] ELECTROCHEMISTRY OF A TETRARUTHENATED COBALT PORPHYRIN AND ITS USE IN MODIFIED ELECTRODES AS SENSORS OF REDUCING ANALYTES
    ARAKI, K
    ANGNES, L
    AZEVEDO, CMN
    TOMA, HE
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1995, 397 (1-2): : 205 - 210
  • [2] Flow-through cell based on an array of gold microelectrodes obtained from modified integrated circuit chips
    Augelli, MA
    Nascimento, VB
    Pedrotti, JJ
    Gutz, IGR
    Angnes, L
    [J]. ANALYST, 1997, 122 (08) : 843 - 847
  • [3] Azevedo CMN, 1998, ELECTROANAL, V10, P467, DOI 10.1002/(SICI)1521-4109(199806)10:7<467::AID-ELAN467>3.0.CO
  • [4] 2-W
  • [5] CHEMICALLY AND PHYSICALLY MODIFIED ELECTRODES - SOME NEW DEVELOPMENTS
    BARENDRECHT, E
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 1990, 20 (02) : 175 - 185
  • [6] BARROS NETO B, 1995, PLANEJAMENTO OTIMIZA
  • [7] MULTIVARIATE DETERMINATION OF GLUCOSE IN WHOLE-BLOOD USING PARTIAL LEAST-SQUARES AND ARTIFICIAL NEURAL NETWORKS BASED ON MIDINFRARED SPECTROSCOPY
    BHANDARE, P
    MENDELSON, Y
    PEURA, RA
    JANATSCH, G
    KRUSEJARRES, JD
    MARBACH, R
    HEISE, HM
    [J]. APPLIED SPECTROSCOPY, 1993, 47 (08) : 1214 - 1221
  • [8] Box GEP., 1978, Statistics for experimenters
  • [9] BROWN SD, 1992, ANAL CHEM, V64, pR22
  • [10] *CAMO, 1996, UNSCR US GUID VERS 6