Automated detection of shockable and non-shockable arrhythmia using novel wavelet-based ECG features

被引:39
作者
Sharma, Manish [1 ]
Singh, Swapnil [2 ]
Kumar, Abhishek [3 ]
Tan, Ru San [4 ]
Acharya, U. Rajendra [5 ,6 ,7 ]
机构
[1] Inst Infrastruct Technol Res & Management, Dept Elect Engn, Ahmadabad, Gujarat, India
[2] Natl Inst Ind Engn, Dept Project Management, Mumbai, Maharashtra, India
[3] Indian Inst Technol, Dept Civil Engn, Madras, Tamil Nadu, India
[4] Natl Heart Care Ctr Singapore, Dept Cardiol, Singapore, Singapore
[5] Ngee Ann Polytech, Dept Elect & Comp Engn, Singapore 599489, Singapore
[6] SUSS, Sch Sci & Technol, Dept Biomed Engn, Singapore, Singapore
[7] Kumamoto Univ, IROAST, Kumamoto, Japan
关键词
Shockable; Heart; ECG; Wavelets; Optimization problem; Machine learning; Semi-definite program; Filter design; Classification; HEART-RATE-VARIABILITY; VENTRICULAR-FIBRILLATION; FILTER BANKS; DIAGNOSIS; SIGNALS; FAILURE; MANAGEMENT;
D O I
10.1016/j.compbiomed.2019.103446
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Malignant arrhythmia can lead to sudden cardiac death (SCD). Shockable arrhythmia can be terminated with device electrical shock therapies. Ventricular-tachycardia (VT) and ventricular fibrillation (VF) are responsive to electrical anti-tachycardia pacing therapy and defibrillation which help to restore normal electrical and mechanical function of the heart. In contrast, non-shockable arrhythmia like asystole and bradycardia are not responsive to electric shock therapy. Distinguishing between shockable and non-shockable arrhythmia is an important diagnostic challenge that has practical clinical relevance. It is difficult to accurately differentiate between these two types of arrhythmia by manual inspection of electrocardiogram (ECG) segments within the short time duration before triggering the device for electrical therapy. Automated defibrillators are equipped with automatic shockable arrhythmia detection algorithms based on ECG morphological features, which may possess variable diagnostic performance depending on machine models. In our work, we have designed a robust system using wavelet decomposition filter banks for extraction of features from the ECG signal and then classifying the features. We believe this method will improve the accuracy of discriminating between shockable and non-shockable arrhythmia compared with existing conventional algorithms. We used a novel three channel orthogonal wavelet filter bank, which extracted features from ECG epochs of duration 2 s to distinguish between shockable and non-shockable arrhythmia. The fuzzy, Renyi and sample entropies are extracted from the various wavelet coefficients and fed to support vector machine (SVM) classifier for automated classification. We have obtained an accuracy of 98.9%, sensitivity and specificity of 99.08% and 97.11.9%, respectively, using 10-fold cross validation. The area under the receiver operating characteristic has been found to be 0.99 with F1-score of 0.994. The system developed is more accurate than the existing algorithms. Hence, the proposed system can be employed in automated defibrillators inside and outside hospitals for emergency revival of patients suffering from SCD. These automated defibrillators can also be implanted inside the human body for automatic detection of potentially fatal shockable arrhythmia and to deliver an appropriate electric shock to the heart.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] Automated accurate insomnia detection system using wavelet scattering method using ECG signals
    Nishant Sharma
    Manish Sharma
    Hardik Telangore
    U Rajendra Acharya
    Applied Intelligence, 2024, 54 : 3464 - 3481
  • [32] Performance Study of Wavelet-Based ECG Analysis for ST-Segment Detection
    Fujita, Nobuaki
    Sato, Akira
    Kawarasaki, Masatoshi
    2015 38TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2015, : 430 - 434
  • [33] Automated glaucoma detection from fundus images using wavelet-based denoising and machine learning
    Khan, Sibghatullah, I
    Choubey, Shruti Bhargava
    Choubey, Abhishek
    Bhatt, Abhishek
    Naishadhkumar, Pandya Vyomal
    Basha, Mohammed Mahaboob
    CONCURRENT ENGINEERING-RESEARCH AND APPLICATIONS, 2022, 30 (01): : 103 - 115
  • [34] Automated identification of sleep disorders using wavelet-based features extracted from electrooculogram and electromyogram signals
    Sharma, Manish
    Darji, Jay
    Thakrar, Madhav
    Acharya, U. Rajendra
    COMPUTERS IN BIOLOGY AND MEDICINE, 2022, 143
  • [35] Automated Detection of QRS Complex in ECG Signal using Wavelet Transform
    Rani, Rekha
    Chouhan, V. S.
    Sinha, H. P.
    INTERNATIONAL JOURNAL OF COMPUTER SCIENCE AND NETWORK SECURITY, 2015, 15 (01): : 1 - 5
  • [36] Automated Detection of QRS Complex in ECG Signal using Wavelet Transform
    Rani, Rekha
    Chouhan, V. S.
    Sinha, H. P.
    INTERNATIONAL JOURNAL OF COMPUTER SCIENCE AND NETWORK SECURITY, 2016, 16 (01): : 109 - 113
  • [37] Efficient ECG Signal Analysis using Wavelet Technique for Arrhythmia Detection: An ANFIS Approach
    Khandait, P. D.
    Bawane, N. G.
    Limaye, S. S.
    SECOND INTERNATIONAL CONFERENCE ON DIGITAL IMAGE PROCESSING, 2010, 7546
  • [38] A Multiclass Epilepsy Identification Technique Using Wavelet-Based Features
    Bellegdi, Sameh A.
    Deriche, Mohamed
    Arafat, Samer M. A.
    2018 15TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS AND DEVICES (SSD), 2018, : 1246 - 1251
  • [39] Review: Multi-lead Discrete Wavelet-based ECG Arrhythmia Recognition via Sequential Particle Support Vector Machine Classifiers
    Homaeinezhad, Mohammad Reza
    Ghaffari, Ali
    Rahmani, Reza
    JOURNAL OF MEDICAL AND BIOLOGICAL ENGINEERING, 2012, 32 (06) : 381 - 396
  • [40] Study of features based on nonlinear dynamical modeling in ECG arrhythmia detection and classification
    Owis, MI
    Abou-Zied, AH
    Youssef, ABM
    Kadah, YM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (07) : 733 - 736