Flat ribbon cable sensors for measurement of soil electrical conductivity using time domain reflectometry

被引:6
作者
Bhuyan, Md. Habibullah [1 ]
Scheuermann, Alexander [1 ]
Mishra, Partha Narayan [1 ]
Bodin, Didier [2 ]
Becker, Rolf [3 ]
机构
[1] Univ Queensland, Sch Civil Engn, Brisbane, Qld, Australia
[2] ARRB Grp, Pavement & Surfacing, Vermont South, Vic, Australia
[3] Rhine Waal Univ Appl Sci, Fac Commun & Environm, Cologne, Germany
关键词
Electrical conductivity; time domain reflectometry (TDR); rod probe sensor; flat ribbon cable; pavement performance; WATER-CONTENT; DENSITY;
D O I
10.1080/19386362.2018.1429703
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Salt movement and accumulation within the subgrade, subbase or base materials of pavement is a major concern for practitioners and researches in the area of transportation geotechnics, essentially because it prompts damage to the thin bituminous surface layer causing weakening of bonding and cracking of the road surface. In this regard, the electrical conductivity (EC) of the pore water or saturated soil is a strong indicator of the salinity of the pavement materials. With this in view, this paper describes the electrical conductivity measurement using time domain reflectometry (TDR) employing flat ribbon cable (FRC) sensors of several lengths. This also enables a continuous measurement, and helps overcome the uncertainties associated with the point-wise measurements made by the conventional rod probe sensors. Calibration of the rod probe and the FRC sensors is depicted in detail in this paper, along with several calibration functions. It is expected from the study that the FRC sensors may particularly be useful in spatial monitoring of the state parameters of the soil along long sections of the pavement in a continuous and non-invasive manner.
引用
收藏
页码:608 / 616
页数:9
相关论文
共 25 条
[1]  
[Anonymous], 2017, P 19 INT C SOIL MECH
[2]  
[Anonymous], IMPACTS SALINITY
[3]   The electrical resistivity log as an aid in determining some reservoir characteristics [J].
Archie, GE .
TRANSACTIONS OF THE AMERICAN INSTITUTE OF MINING AND METALLURGICAL ENGINEERS, 1942, 146 :54-61
[4]   Use of Time Domain Reflectometry to Estimate Moisture and Density of Unbound Road Materials Laboratory Calibration and Field Investigation [J].
Bhuyan, Habibullah ;
Scheuermann, Alexander ;
Bodin, Didier ;
Becker, Rolf .
TRANSPORTATION RESEARCH RECORD, 2017, (2655) :71-81
[5]  
BONNELL RB, 1991, CAN AGR ENG, V33, P225
[6]   TIME-DOMAIN REFLECTOMETRY - SIMULTANEOUS MEASUREMENT OF SOIL-WATER CONTENT AND ELECTRICAL-CONDUCTIVITY WITH A SINGLE PROBE [J].
DALTON, FN ;
HERKELRATH, WN ;
RAWLINS, DS ;
RHOADES, JD .
SCIENCE, 1984, 224 (4652) :989-990
[7]   THE TIME-DOMAIN REFLECTOMETRY METHOD FOR MEASURING SOIL-WATER CONTENT AND SALINITY [J].
DALTON, FN ;
VANGENUCHTEN, MT .
GEODERMA, 1986, 38 (1-4) :237-250
[8]  
De Carteret R.S., 2010, 24 ARRB C MELB AUSTR
[9]  
De Carteret R.S., 2012, 25 ARRB C PERTH AUST
[10]  
Drnevich VP, 2005, CAN GEOTECH J, V42, P1053, DOI [10.1139/t05-047, 10.1139/T05-047]