A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes

被引:54
作者
Jena, R. [1 ]
Kirkby, N. F. [2 ]
Burton, K. E. [1 ]
Hoole, A. C. F. [1 ]
Tan, L. T. [1 ]
Burnet, N. G. [3 ]
机构
[1] Cambridge Univ Hosp NHS Fdn Trust, Ctr Oncol, Cambridge CB2 0QQ, England
[2] Univ Surrey, Fac Engn & Phys Sci, Guildford GU2 7XH, Surrey, England
[3] Univ Cambridge, Dept Oncol, Addenbrookes Hosp, Cambridge CB2 0QQ, England
关键词
3-DIMENSIONAL ANALYSIS; CT IMAGES; DELINEATION; INTEROBSERVER; VARIABILITY; PROSTATE; CANCER; PET;
D O I
10.1259/bjr/27674581
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Quantitative assessment of target volume contouring in radiotherapy treatment planning is an important aspect of quality assessment and educational exercises. The Conformity Index (CI) is a volume-based statistic frequently used for this purpose. Although the CI is relatively simple to understand and can be calculated using most treatment planning systems, it does not provide any information on the differences in shape between the two volumes. We present a new morphometric (shape-based) statistic known as the "mean distance to conformity" (MDC). For a specific volume that is being evaluated against a reference volume, the MDC represents the average distance that all outlying points in the volume must be moved in order to achieve perfect conformity with the reference volume. The MDC comprises a component related to under-contouring (where the evaluation volume is smaller than the reference volume) and a component related to over-contouring (where the evaluation extends beyond the reference volume). Furthermore, voxel-by-voxel information on conformity errors can also be displayed using a volume-error histogram. Calculation of MDC statistics is achieved using a three-dimensional grid search algorithm. By using a range of scenarios comprising both theoretical and actual clinical volumes, we demonstrate the increased utility of the MDC for the detection of contouring errors.
引用
收藏
页码:44 / 51
页数:8
相关论文
共 15 条
[1]   Intraobserver and interobserver variability in GTV delineation on FDG-PET-CT images of head and neck cancers [J].
Breen, Stephen L. ;
Publicover, Julia ;
De Silva, Shiroma ;
Pond, Greg ;
Brock, Kristy ;
O'Sullivan, Brian ;
Cummings, Bernard ;
Dawson, Laura ;
Keller, Anne ;
Kim, John ;
Ringash, Jolie ;
Yu, Eugene ;
Hendler, Aaron ;
Waldron, John .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 68 (03) :763-770
[2]  
Burton K, 2008, RADIOTHER ONCOL, V88, pS27
[3]   Titanium clip placement to allow accurate tumour bed localisation following breast conserving surgery - Audit on behalf of the IMPORT Trial Management Group [J].
Coles, C. E. ;
Wilson, C. B. ;
Cumming, J. ;
Benson, J. R. ;
Forouhi, P. ;
Wilkinson, J. S. ;
Jena, R. ;
Wishart, G. C. .
EJSO, 2009, 35 (06) :578-582
[4]   Quantification of shape variation of prostate and seminal vesicles during external beam radiotherapy [J].
Deurloo, KEI ;
Steenbakkers, RJHM ;
Zijp, LJ ;
de Bois, JA ;
Nowak, PJCM ;
Rasch, CRN ;
van Herk, M .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (01) :228-238
[5]  
Feuvret L, 2004, Cancer Radiother, V8, P108, DOI 10.1016/j.canrad.2003.12.002
[6]   Conformity index:: A review [J].
Feuvret, L ;
Noël, G ;
Mazeron, JJ ;
Bey, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (02) :333-342
[7]   Organ contouring for prostate cancer:: Interobserver and internal organ motion variability [J].
Gual-Arnau, X ;
Ibáñez-Gual, MV ;
Lliso, F ;
Roldán, S .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (08) :639-647
[8]  
MCKENZIE A, 2003, BRIT I RADIOLOGY WOR
[9]   Target volume delineation for partial breast radiotherapy planning: Clinical characteristics associated with low interobserver concordance [J].
Petersen, Ross P. ;
Truong, Pauline T. ;
Kader, Hosam A. ;
Berthelet, Eric ;
Lee, Junella C. ;
Hilts, Michelle L. ;
Kader, Adam S. ;
Beckham, Wayne A. ;
Olivotto, Ivo A. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (01) :41-48
[10]   Comparison of human and automatic segmentations of kidneys from CT images [J].
Rao, M ;
Stough, J ;
Chi, YY ;
Muller, K ;
Tracton, G ;
Pizer, SM ;
Chaney, EL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03) :954-960