A fixed-jaw method to protect critical organs during intensity-modulated radiotherapy

被引:15
作者
Chen, Jiayun [1 ]
Chen, Xinyuan [1 ]
Huang, Manni [2 ]
Dai, Jianrong [1 ]
机构
[1] Chinese Acad Med Sci, Canc Hosp Inst, Dept Radiat Oncol, Beijing 100021, Peoples R China
[2] Chinese Acad Med Sci, Canc Hosp Inst, Dept Gynecol Oncol, Beijing 100021, Peoples R China
关键词
IMRT; Treatment planning; Fixed jaw; Critical organ protection;
D O I
10.1016/j.meddos.2014.05.006
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Intensity-modulated radiotherapy (IMRT) plays an important role in cancer radiotherapy. For some patients being treated with IMRT, the extremely low tolerances of critical organs (such as lens, ovaries, and testicles) cannot be met during treatment planning. The aim of this article is to introduce a new planning method to overcome that problem. In current planning practice, jaw positions are automatically set to cover all target volumes by the planning system (e.g., Pinnacle(3) system). Because of such settings, critical organs may be fully blocked by the multileaf collimator (MLC), but they still sit in the field that is shaped by collimator jaws. These critical organs receive doses from the transmission and leakage of MLC leaves. We manually fixed jaw positions to block them to further reduce such dcises. This method has been used for different treatment sites in our clinic, and it was thoroughly evaluated in patients with radical hysterectomy plus ovarian transposition after surgery. For each patient, 2 treatment plans were designed with the same optimization parameters: the original plan with automatically chosen jaw positions (called O-plan) and the plan with fixed-jaw positions (named F-plan). In the F-plan, the jaws were manually fixed to block the ovaries. For target coverage, the mean conformity index (CI) of the F-plan (1.28 +/- 0.02) was remarkably lower than that of the O-plan (1.53 +/- 0.09) (p < 0.05). The F-plan and the O-plan performed similarly in target dose homogeneity. Meanwhile, for the critical organ sparing, the mean dose of both ovaries were much lower in the F-plan than that in the O-plan (p < 0.05). The V-20, V-30, and V-40 of bladder were also lower in the F-plan (93.57 +/- 1.98, 73.99 +/- 5.76, and 42.33 +/- 3.7, respectively) than those in the O-plan (97.98 +/- 1.11, 85.07 +/- 4.04, and 49.71 +/- 3.63, respectively) (p < 0.05). The maximum dose to the spinal cord planning organ at risk (OAR) volume (PRV) in the O-plan (3940.24 +/- 102.8) was higher than that in the F-plan (3628.18 +/- 131.45) with significant differences (p < 0.01). For other OARs, there were no significant differences in doses between these 2 plans except that the high-dose regions of the rectum were higher for V-40 in the O-plan than that in the F-plan (p < 0.01). But the monitor units (MUs) in the F-plan were 1.4 times as much as that in the O-plan. Thus the treatment time could be longer by using the F-plan. As it results in more MUs in spite of better plan quality, it is recommended to be used only in situations in which clinical requirements to critical organs cannot be met with the regular method. (C) 2014 Published by Elsevier Inc. On behalf of American Association of Medical Dosimetrists.
引用
收藏
页码:325 / 329
页数:5
相关论文
共 13 条
  • [1] alta JR, 2003, INTENSITY MODULATED, P888
  • [2] Clifford Chao K.S, 2005, PRACTICAL ESSENTIALS, P432
  • [3] Green D.M., ONCOLOGIST, V2, P171
  • [4] Static jaw collimation settings to minimize radiation dose to normal brain tissue during stereotactic radiosurgery
    Han, Eun Young
    Zhang, Xin
    Yan, Yulong
    Sharma, Sunil
    Penagaricano, Jose
    Moros, Eduardo
    Corry, Peter
    [J]. MEDICAL DOSIMETRY, 2012, 37 (04) : 391 - 395
  • [5] Khan F.M, 2003, PHYS RAD THERAPY, P44
  • [6] Volumetric intensity-modulated Arc (RapidArc) therapy for primary hepatocellular carcinoma: comparison with intensity-modulated radiotherapy and 3-D conformal radiotherapy
    Kuo, Yu-Cheng
    Chiu, Ying-Ming
    Shih, Wen-Pin
    Yu, Hsiao-Wei
    Chen, Chia-Wen
    Wong, Pei-Fong
    Lin, Wei-Chan
    Hwang, Jeng-Jong
    [J]. RADIATION ONCOLOGY, 2011, 6
  • [7] Lenhard Jr R.E., 2001, CLIN ONCOLOGY, P919
  • [8] PECK WS, 1940, RADIOLOGY, V34, P176
  • [9] Leaf transmission reduction using moving jaws for dynamic MLC IMRT
    Schmidhalter, D.
    Fix, M. K.
    Niederer, P.
    Mini, R.
    Manser, P.
    [J]. MEDICAL PHYSICS, 2007, 34 (09) : 3674 - 3687
  • [10] Spirou S, 2003, PRACTICAL GUIDE INTE, P71