Hydrophilic carbon nanoparticulates at the surface of carbon paste electrode improve determination of paracetamol, phenylephrine and dextromethorphan

被引:35
作者
Amiri, Mandana [1 ]
Rezapour, Farahnaz [1 ]
Bezaatpour, Abolfazl [1 ]
机构
[1] Univ Mohaghegh Ardabili, Dept Chem, Ardebil, Iran
关键词
Paracetamol; Phenylephrine; Dextromethorphan; Carbon nanoparticles; Electrochemical sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; SPECTROFLUOROMETRIC DETERMINATION; ELECTROCATALYTIC DETERMINATION; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL OXIDATION; SENSITIVE DETERMINATION; HUMAN PLASMA; ACETAMINOPHEN; PHARMACEUTICALS; COMPOSITE;
D O I
10.1016/j.jelechem.2014.10.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, a novel carbon nanoparticles (Emperor 2000 (TM))-modified carbon paste electrode (CNP/CPE) was fabricated and employed for determination of paracetamol (PA), phenylephrine (PHE) and dextromethorphan (DX) with good selectivity and high sensitivity. The paste design is based on (i) a hydrophobic binder, (ii) hydrophobic graphite as conductive component, and (iii) a thin film of nanoparticulate with hydrophilic surface to provide sensitivity and selectivity. Paracetamol, phenylephrine and dextromethorphan are frequently associated in pharmaceutical formulations against the common cold. Then determination of these compounds in a mixture is very important in pharmaceuticals and human fluids. CNP/CPE displayed excellent electrochemical catalytic activities towards paracetamol, phenylephrine and dextromethorphan oxidation. Using differential pulse voltammetry (DPV), a trace determination of PA, PHE and DX has been explored at the surface of modified electrode in presence of each other. Peak currents of PA, PHE and DX increased linearly with their concentrations at the ranges of 1.0 x 10(-7)-1.0 x 10(-3) M, 8.0 x 10(-6)-8.0 x 10(-5) M and 8.0 x 10(-6)-8.0 x 10(-4)M, and the detection limits were estimated 1.5 x 10(-8), 9.5 x 10(-7) and 2.9 x 10(-6)M, respectively. The modified electrode displayed strong function for resolving the overlapping voltammetric responses of PHE and DX into two well-defined voltammetric peaks. Method was applied successfully to the determination of PA, PHE and DX in real samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 18
页数:9
相关论文
共 54 条
[1]   Simple chromatography method for simultaneous determination of dextromethorphan and its main metabolites in human plasma with fluorimetric detection [J].
Afshar, M ;
Rouini, MR ;
Amini, M .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 802 (02) :317-322
[2]   Spectrophotometric determination of pipazethate HCl, dextromethorphan HBr and drotaverine HCl in their pharmaceutical preparations [J].
Amin, Alaa S. ;
El-Sheikh, Ragaa ;
Zahran, Faten ;
Abou El-Fetouh Gouda, Ayman .
SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2007, 67 (3-4) :1088-1093
[3]   Electrostatic accumulation and determination of triclosan in ultrathin carbon nanoparticle composite film electrodes [J].
Amiri, Mandana ;
Shahrokhian, Saeed ;
Psillakis, Elefteria ;
Marken, Frank .
ANALYTICA CHIMICA ACTA, 2007, 593 (01) :117-122
[4]   Nickel (II) incorporated AlPO-5 modified carbon paste electrode for determination of thioridazine in human serum [J].
Amiri, Mandana ;
Sohrabnezhad, Shabnam ;
Rahimi, Azad .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2014, 37 :342-347
[5]   Cobalt Flower-like Nanostructure as Modifier for Electrocatalytic Determination of Chloropheniramine [J].
Amiri, Mandana ;
Alimoradi, Mohsen ;
Nekoueian, Khadijeh ;
Bezaatpour, Abolfazl .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2012, 51 (44) :14384-14389
[6]   Simultaneous voltammetric determination of uric acid and ascorbic acid using carbon paste/cobalt Schiff base composite electrode [J].
Amiri, Mandana ;
Bezaatpour, Abolfazl ;
Pakdel, Zohreh ;
Nekoueian, Khadijeh .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (06) :2187-2195
[7]   Electrocatalytic determination of sumatriptan on the surface of carbon-paste electrode modified with a composite of cobalt/Schiff-base complex and carbon nanotube [J].
Amiri, Mandana ;
Pakdel, Zohreh ;
Bezaatpour, Abolfazi ;
Shahrokhian, Saeed .
BIOELECTROCHEMISTRY, 2011, 81 (02) :81-85
[8]  
[Anonymous], 1999, MARTINDALE COMPLETE
[9]   Spectrofluorimetric determination of phenylephrine in the presence of a large excess of paracetamol [J].
Arancibia, JA ;
Nepote, AJ ;
Escandar, GM ;
Olivieri, AC .
ANALYTICA CHIMICA ACTA, 2000, 419 (02) :159-168
[10]   Electrochemical sensing with electrodes modified with molecularly imprinted polymer films [J].
Blanco-López, MC ;
Gutiérrez-Fernández, S ;
Lobo-Castañón, MJ ;
Miranda-Ordieres, AJ ;
Tuñón-Blanco, P .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2004, 378 (08) :1922-1928