Hydrophilic carbon nanoparticulates at the surface of carbon paste electrode improve determination of paracetamol, phenylephrine and dextromethorphan

被引:35
|
作者
Amiri, Mandana [1 ]
Rezapour, Farahnaz [1 ]
Bezaatpour, Abolfazl [1 ]
机构
[1] Univ Mohaghegh Ardabili, Dept Chem, Ardebil, Iran
关键词
Paracetamol; Phenylephrine; Dextromethorphan; Carbon nanoparticles; Electrochemical sensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; SPECTROFLUOROMETRIC DETERMINATION; ELECTROCATALYTIC DETERMINATION; VOLTAMMETRIC DETERMINATION; ELECTROCHEMICAL OXIDATION; SENSITIVE DETERMINATION; HUMAN PLASMA; ACETAMINOPHEN; PHARMACEUTICALS; COMPOSITE;
D O I
10.1016/j.jelechem.2014.10.006
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, a novel carbon nanoparticles (Emperor 2000 (TM))-modified carbon paste electrode (CNP/CPE) was fabricated and employed for determination of paracetamol (PA), phenylephrine (PHE) and dextromethorphan (DX) with good selectivity and high sensitivity. The paste design is based on (i) a hydrophobic binder, (ii) hydrophobic graphite as conductive component, and (iii) a thin film of nanoparticulate with hydrophilic surface to provide sensitivity and selectivity. Paracetamol, phenylephrine and dextromethorphan are frequently associated in pharmaceutical formulations against the common cold. Then determination of these compounds in a mixture is very important in pharmaceuticals and human fluids. CNP/CPE displayed excellent electrochemical catalytic activities towards paracetamol, phenylephrine and dextromethorphan oxidation. Using differential pulse voltammetry (DPV), a trace determination of PA, PHE and DX has been explored at the surface of modified electrode in presence of each other. Peak currents of PA, PHE and DX increased linearly with their concentrations at the ranges of 1.0 x 10(-7)-1.0 x 10(-3) M, 8.0 x 10(-6)-8.0 x 10(-5) M and 8.0 x 10(-6)-8.0 x 10(-4)M, and the detection limits were estimated 1.5 x 10(-8), 9.5 x 10(-7) and 2.9 x 10(-6)M, respectively. The modified electrode displayed strong function for resolving the overlapping voltammetric responses of PHE and DX into two well-defined voltammetric peaks. Method was applied successfully to the determination of PA, PHE and DX in real samples. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:10 / 18
页数:9
相关论文
共 50 条
  • [1] Chemometrics-assisted electrochemical determination of dextromethorphan hydrobromide and phenylephrine hydrochloride by carbon paste electrode
    Sefid-Sefidehkhan, Yasaman
    Khoshkam, Maryam
    Amiri, Mandana
    CHEMICAL PAPERS, 2021, 75 (12) : 6565 - 6573
  • [2] Chemometrics-assisted electrochemical determination of dextromethorphan hydrobromide and phenylephrine hydrochloride by carbon paste electrode
    Yasaman Sefid-Sefidehkhan
    Maryam Khoshkam
    Mandana Amiri
    Chemical Papers, 2021, 75 : 6565 - 6573
  • [3] Simultaneous voltammetric determination of paracetamol, cetirizine and phenylephrine using a multiwalled carbon nanotube-platinum nanoparticles nanocomposite modified carbon paste electrode
    Kalambate, Pramod K.
    Srivastava, Ashwini K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 233 : 237 - 248
  • [4] Sensitive determination of paracetamol using a graphene-modified carbon- paste electrode
    Bahramipur, Hossein
    Jalali, Fahimeh
    AFRICAN JOURNAL OF PHARMACY AND PHARMACOLOGY, 2012, 6 (17): : 1298 - 1305
  • [5] DETERMINATION OF PHENYLEPHRINE WITH A MODIFIED CARBON-PASTE ELECTRODE
    PERLADO, JC
    ZAPARDIEL, A
    BERMEJO, E
    PEREZ, JA
    HERNANDEZ, L
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 83 - 90
  • [6] Electrochemical Sensor for the Determination of Paracetamol at Carbamazepine Film Coated Carbon Paste Electrode
    Teradale, Amit B.
    Lamani, Shekappa D.
    Ganesh, Pattan S.
    Swamy, Bahaddurghatta E. Kumara
    Das, Swastika N.
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-INTERNATIONAL JOURNAL OF RESEARCH IN PHYSICAL CHEMISTRY & CHEMICAL PHYSICS, 2018, 232 (03): : 345 - 358
  • [7] Electrocatalytic determination of morphine at the surface of a carbon paste electrode spiked with a hydroquinone derivative and carbon nanotubes
    Shishehbore, M. Reza
    Zare, Hamid R.
    Nematollahi, Davood
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2012, 665 : 45 - 51
  • [8] Simultaneous Determination of Paracetamol, Dextromethorphan, Phenylephrine and Chlorpheniramine Using Partial Least Squares
    Shariati-Rad, Masoud
    Irandoust, Mohsen
    Amin, Niloufar
    Ahmadi, Farhad
    CURRENT PHARMACEUTICAL ANALYSIS, 2013, 9 (02) : 183 - 190
  • [9] Simultaneous Determination of Ascorbic Acid, Paracetamol and Phenylephrine: Carbon Nanotubes Ceramic Electrode as a Renewable Electrode
    Habibi, Biuck
    Jahanbakhshi, Mojtaba
    ANALYTICAL & BIOANALYTICAL ELECTROCHEMISTRY, 2015, 7 (01): : 45 - 58
  • [10] Application of an electro-activated glassy-carbon electrode to the determination of acetaminophen (paracetamol) in surface waters
    Berto, Silvia
    Carena, Luca
    Valmacco, Federico
    Barolo, Claudia
    Conca, Eleonora
    Vione, Davide
    Buscaino, Roberto
    Fiorito, Marina
    Bussi, Carlo
    Abollino, Ornella
    Malandrino, Mery
    ELECTROCHIMICA ACTA, 2018, 284 : 279 - 286