Variable-Density Parallel Imaging With Partially Localized Coil Sensitivities

被引:13
作者
Cukur, Tolga [1 ]
Santos, Juan M. [1 ]
Pauly, John M. [1 ]
Nishimura, Dwight G. [1 ]
机构
[1] Stanford Univ, Dept Elect Engn, Informat Syst Lab, Stanford, CA 94305 USA
基金
美国国家卫生研究院;
关键词
Aliasing artifact; image reconstruction; parallel imaging; self calibration; variable density; SPIRAL TRAJECTORIES; RECONSTRUCTION; GRAPPA; MRI; COMBINATION; INVERSION; PROFILES; SENSE; ARRAY; SSFP;
D O I
10.1109/TMI.2010.2042805
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Partially parallel imaging with localized sensitivities is a fast parallel image reconstruction method for both Cartesian and non-Cartesian trajectories, but suffers from aliasing artifacts when there are deviations from the assumption of perfect localization. Such reconstructions would normally crop the individual coil images to remove the artifacts prior to combination. However, the sampling densities in variable-density k-space trajectories support different field-of-views for separate regions in k-space. In fact, the higher sampling density of low frequencies can be used to reconstruct a bigger field-of-view without introducing aliasing artifacts and the resulting image signal-to-noise ratio (SNR) can be improved. A novel, fast variable-density parallel imaging method is presented, which reconstructs different field-of-views from separate frequencies according to the local sampling density in k-space. Aliasing-suppressed images can be produced with high SNR-efficiency without the need for accurate estimation of coil sensitivities and complex or iterative computations.
引用
收藏
页码:1173 / 1181
页数:9
相关论文
共 45 条
[1]   Self-calibrated GRAPPA method for 2D and 3D radial data [J].
Arunachalam, Arjun ;
Samsonov, Alexey ;
Block, Walter F. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (05) :931-938
[2]  
Blaimer Martin, 2004, Top Magn Reson Imaging, V15, P223, DOI 10.1097/01.rmr.0000136558.09801.dd
[3]  
Bracewell Ronald N., 2000, The Fourier Transform and Its Applications
[4]   Combination of signals from array coils using image-based estimation of coil sensitivity profiles [J].
Bydder, M ;
Larkman, DJ ;
Hajnal, JV .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (03) :539-548
[5]   Multiple-profile homogeneous image combination:: Application to phase-cycled SSFP and multicoil imaging [J].
Cukur, Tolga ;
Lustig, Michael ;
Nishimura, Dwight G. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (03) :732-738
[6]   Varying kernel-extent gridding reconstruction for undersampled variable-density spirals [J].
Cukur, Tolga ;
Santos, Juan M. ;
Nishimura, Dwight G. ;
Pauly, John M. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) :196-201
[7]   Influence of multichannel combination, parallel imaging and other reconstruction techniques on MRI noise characteristics [J].
Dietrich, Olaf ;
Raya, Jose G. ;
Reeder, Scott B. ;
Ingrisch, Michael ;
Reiser, Maximilian F. ;
Schoenberg, Stefan O. .
MAGNETIC RESONANCE IMAGING, 2008, 26 (06) :754-762
[8]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210
[9]  
Griswold MA, 2000, MAGN RESON MED, V44, P602, DOI 10.1002/1522-2594(200010)44:4<602::AID-MRM14>3.0.CO
[10]  
2-5