Bioorthogonal Reaction-Mediated ELISA Using Peroxide Test Strip as Signal Readout for Point-of-Care Testing

被引:53
作者
Ran, Bei [1 ,2 ]
Xianyu, Yunlei [2 ]
Dong, Mingling [1 ,2 ]
Chen, Yiping [2 ]
Qian, Zhiyong [1 ]
Jiang, Xingyu [2 ,3 ]
机构
[1] Sichuan Univ, West China Hosp, State Key Lab Biotherapy, Collaborat Innovat Ctr Biotherapy, Chengdu 610041, Peoples R China
[2] Natl Ctr Nanosci & Technol, CAS Key Lab Biol Effects Nanomat & Nanosafety, CAS Ctr Excellence Nanosci, Beijing 100190, Peoples R China
[3] Univ Chinese Acad Sci, 19 A Yuquan Rd, Beijing 100049, Peoples R China
基金
美国国家科学基金会;
关键词
ULTRASENSITIVE DETECTION; CLICK CHEMISTRY; ELECTROCHEMICAL DETECTION; SENSITIVE DETECTION; DISEASE BIOMARKERS; CARBON NANOTUBES; CANCER BIOMARKER; P24; ANTIGEN; SKIN PATCH; CELLS;
D O I
10.1021/acs.analchem.7b00831
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This work demonstrates a highly sensitive peroxide test strip (PTS)-based enzyme-linked immunosorbent assay (ELISA) for both qualitative and quantitative detection of drugs of abuse (morphine) and disease biomarkers (interleukin-6 and HIV-1 capsid antigen p24): This color-based PTS is-a commercially available product with advantages of low-cost, easy operation, and portability, and it is an ideal signal readout strategy in ELISA to simplify the immunoassay procedures and enable point-of-care testing (POCT). In addition, we introduce-the bioorthogonal reaction that can effectively amplify the signal by controlling the cycles of bioorthogonal reaction to the desirble sensitivity depending on different analytes. The limit of detection is 0.2 ng/mL for morphine, 3.98 pg/mL for interleukin-6, and 11.6 pg/mL for detection of HIV-capsid-antigen (p24)This PTS-ELISA applies to both the qualitative and quantitative detection of IL-6 and p24 in clinical serum samples with good accuracy, which provides a promising tool for the POCT in clinical diagnosis.
引用
收藏
页码:6114 / 6120
页数:7
相关论文
共 48 条
[1]   Point-of-Care Testing for Hb A1c in the Management of Diabetes: A Systematic Review and Metaanalysis [J].
Al-Ansary, Lubna ;
Farmer, Andrew ;
Hirst, Jennifer ;
Roberts, Nia ;
Glasziou, Paul ;
Perera, Rafael ;
Price, Christopher P. .
CLINICAL CHEMISTRY, 2011, 57 (04) :568-576
[2]   Performance evaluation of the Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA, a 4th generation HIV assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma [J].
Bentsen, Christopher ;
McLaughlin, Lisa ;
Mitchell, Elizabeth ;
Ferrera, Carol ;
Liska, Sally ;
Myers, Robert ;
Peel, Sheila ;
Swenson, Paul ;
Gadelle, Stephane ;
Shriver, M. Kathleen .
JOURNAL OF CLINICAL VIROLOGY, 2011, 52 :S57-S61
[3]   Cellphone-Based Hand-Held Microplate Reader for Point-of-Care Testing of Enzyme-Linked Immunosorbent Assays [J].
Berg, Brandon ;
Cortazar, Bingen ;
Tseng, Derek ;
Ozkan, Haydar ;
Feng, Steve ;
Wei, Qingshan ;
Chan, Raymond Yan-Lok ;
Burbano, Jordi ;
Farooqui, Qamar ;
Lewinski, Michael ;
Di Carlo, Dino ;
Garner, Omai B. ;
Ozcan, Aydogan .
ACS NANO, 2015, 9 (08) :7857-7866
[4]   Increasing the Efficacy of Bioorthogonal Click Reactions for Bioconjugation: A Comparative Study [J].
Besanceney-Webler, Christen ;
Jiang, Hao ;
Zheng, Tianqing ;
Feng, Lei ;
del Amo, David Soriano ;
Wang, Wei ;
Klivansky, Liana M. ;
Marlow, Florence L. ;
Liu, Yi ;
Wu, Peng .
ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2011, 50 (35) :8051-8056
[5]   Multilayers enzyme-coated carbon nanotubes as biolabel for ultrasensitive chemiluminescence immunoassay of cancer biomarker [J].
Bi, Sai ;
Zhou, Hong ;
Zhang, Shusheng .
BIOSENSORS & BIOELECTRONICS, 2009, 24 (10) :2961-2966
[6]  
Chan J, 2012, NAT CHEM, V4, P973, DOI [10.1038/nchem.1500, 10.1038/NCHEM.1500]
[7]   Immunosensor based on magnetic relaxation switch and biotin-streptavidin system for the detection of Kanamycin in milk [J].
Chen, Yi Ping ;
Zou, Ming Qiang ;
Qi, Cai ;
Xie, Meng-Xia ;
Wang, Da-Ning ;
Wang, Yan-Fei ;
Xue, Qiang ;
Li, Jin-Feng ;
Chen, Yan .
BIOSENSORS & BIOELECTRONICS, 2013, 39 (01) :112-117
[8]   A dual-readout chemiluminescent-gold lateral flow test for multiplex and ultrasensitive detection of disease biomarkers in real samples [J].
Chen, Yiping ;
Sun, Jiashu ;
Xianyu, Yunlei ;
Yin, Binfeng ;
Niu, Yajing ;
Wang, Songbai ;
Cao, Fengjing ;
Zhang, Xiaoqing ;
Wang, Yu ;
Jiang, Xingyu .
NANOSCALE, 2016, 8 (33) :15205-15212
[9]   Click Chemistry-Mediated Nanosensors for Biochemical Assays [J].
Chen, Yiping ;
Xianyu, Yunlei ;
Wu, Jing ;
Yin, Binfeng ;
Jiang, Xingyu .
THERANOSTICS, 2016, 6 (07) :969-985
[10]   One-step detection of pathogens and cancer biomarkers by the naked eye based on aggregation of immunomagnetic beads [J].
Chen, Yiping ;
Xianyu, Yunlei ;
Sun, Jiashu ;
Niu, Yajing ;
Wang, Yu ;
Jiang, Xingyu .
NANOSCALE, 2016, 8 (02) :1100-1107