Study of oligonucleotide fixation on bilayer lipid membranes by patch-clamp pipette support

被引:0
|
作者
Liu, Nan [1 ]
Gao, Zhixian [1 ]
Zhou, Huanying [1 ]
He, Yonghong [1 ]
Yue, Mingxiang [1 ]
机构
[1] Acad Mil Med Sci, Inst Hyg & Environm Med, Tianjin 300050, Peoples R China
关键词
bilayer lipid membranes; patch-clamp pipette; oligonucleotide;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
One kind of novel BLMs was fabricated by patch-clamp pipette technology characterized in considerably sensitive to changes of electrochemical parameters. Detective currents and voltage presented linear relationship when BLMs was formed and it could be confirmed by Gramicidin method. Ion current was increased by dihexyl(C-12) modified ssDNA fixed on the BLMs and also indicated linear relationship to ssDNA's concentration due to the interaction Of C-12-ssDNA and BLMs. Further more, the regression equations were different from BLMs fixed with ssDNA probe and a blank control BLM in the same experimental conditions. The ssDNA probe was successfully fixed on patch-clamp pipette supported-BLMs. Based on our studies, a biosensor with reactive element of patch-clamp pipette-supported BLMs has been established.
引用
收藏
页码:324 / 326
页数:3
相关论文
共 50 条
  • [1] Study of Oligonucleotide Fixation on Bilayer Lipid Membranes by Patch-clamp Pipette Support
    Nan Liu Zhixian Gao Huanying Zhou Yonghong He Mingxiang Yue Institute of Hygiene and Environmental MedicineAcademy of Military Medical SciencesTianjin China
    稀有金属材料与工程, 2006, (S3) : 324 - 326
  • [2] Detection of SEB gene by bilayer lipid membranes nucleic acid biosensor supported by modified patch-clamp pipette electrode
    Liu, Nan
    Gao, Zhixian
    Zhou, HuanYing
    Yue, Mingxiang
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (9-10): : 2371 - 2376
  • [3] Pipette Hunter: Patch-Clamp Pipette Detection
    Koos, Krisztian
    Molnar, Jozsef
    Horvath, Peter
    IMAGE ANALYSIS, SCIA 2017, PT I, 2017, 10269 : 172 - 183
  • [4] Detection of staphylococcus enterotoxins B gene by bilayer lipid membranes nucleic acid biosensor supported by patch-clamp pipette electrode
    Liu Nan
    Gao Zhi-Xian
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (05) : 638 - 642
  • [5] A PIPETTE HOLDER FOR USE IN PATCH-CLAMP MEASUREMENTS
    BUISMAN, HP
    DEVOS, A
    YPEY, DL
    JOURNAL OF NEUROSCIENCE METHODS, 1990, 31 (02) : 89 - 91
  • [6] FORMATION OF LIPID BILAYER-MEMBRANES ON PATCH-CLAMP PIPETTES - A RECONSTITUTION TECHNIQUE FOR IONIC CHANNELS
    CORONADO, R
    LATORRE, R
    BIOPHYSICAL JOURNAL, 1983, 41 (02) : A56 - A56
  • [7] PATCH-CLAMP RECORDING OF ION CHANNELS - INTERFERING EFFECTS OF PATCH PIPETTE GLASS
    ZUAZAGA, C
    STEINACKER, A
    NEWS IN PHYSIOLOGICAL SCIENCES, 1990, 5 : 155 - 158
  • [8] A PATCH-CLAMP STUDY OF ELECTRICAL BREAKDOWN OF CELL-MEMBRANES
    SUKHAREV, SI
    POPOV, SV
    CHERNOMORDIK, LV
    ABIDOR, IG
    BIOLOGICHESKIE MEMBRANY, 1985, 2 (01): : 77 - 86
  • [9] A device for automated control of pipette internal pressure for patch-clamp recording
    Heyward, PM
    Shipley, MT
    JOURNAL OF NEUROSCIENCE METHODS, 2003, 123 (01) : 109 - 115
  • [10] Inter-layer slide and stress relaxation in a bilayer lipid membrane in the patch-clamp setting
    Mukhin, SI
    Baoukina, SV
    BIOLOGICHESKIE MEMBRANY, 2004, 21 (06): : 506 - 517