Frequency noise processes in a strontium ion optical clock

被引:15
作者
Barwood, G. P. [1 ]
Huang, G. [1 ]
King, S. A. [1 ]
Klein, H. A. [1 ]
Gill, P. [1 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
optical clocks; ion cooling; magnetic field noise; 674; NM; TRANSITION; STANDARDS; LASER;
D O I
10.1088/0953-4075/48/3/035401
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A recent comparison of the frequencies of a pair of optical clocks based on the 674 nm S-2(1/2)-D-2(5/2) optical clock transition in Sr-88(+) has highlighted the need to understand factors affecting frequency instability. We have developed statistical models to show that our clock is capable of reaching the quantum projection noise limit; for our clock using 100 ms probe pulses, this is similar to 3 x 10(-15)/root tau. However, this optical clock uses atomic transitions with a linear Zeeman shift, which can lead to a degradation in stability in the presence of magnetic field noise. We show that this generally leads to an increase in white frequency noise, even in cases dominated by magnetic field flicker or random walk noise. By taking into account both the quantum projection and magnetic field noise we are able to explain our observed frequency instabilities. This analysis will relate to any optical clock with a linear Zeeman shift where cancellation of this shift is achieved by interrogating pairs of components. Furthermore, implementing automatic control of lasers and minimization of micromotion requires pausing of the frequency servo occasionally; this leads to only a small degradation of frequency stability.
引用
收藏
页数:7
相关论文
共 26 条
[1]   STATISTICS OF ATOMIC FREQUENCY STANDARDS [J].
ALLAN, DW .
PROCEEDINGS OF THE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS, 1966, 54 (02) :221-&
[2]  
Barnes J A, 1990, 1318 NIST, V1318
[3]   Agreement between two 88Sr+ optical clocks to 4 parts in 1017 [J].
Barwood, G. P. ;
Huang, G. ;
Klein, H. A. ;
Johnson, L. A. M. ;
King, S. A. ;
Margolis, H. S. ;
Szymaniec, K. ;
Gill, P. .
PHYSICAL REVIEW A, 2014, 89 (05)
[4]   Automatic laser control for a 88Sr+ optical frequency standard [J].
Barwood, G. P. ;
Gill, P. ;
Huang, G. ;
Klein, H. A. .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (05)
[5]   Observation of a Sub-10-Hz linewidth 88Sr+ 2S1/2-2D5/2 clock transition at 674 nm [J].
Barwood, Geoffrey P. ;
Gill, Patrick ;
Huang, Guilong ;
Klein, Hugh A. .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (02) :226-229
[6]   Development of an ultra-narrow diode laser for interrogating the 674 nm 2S1/2-2D5/2 "clock" transition in Sr+ [J].
Barwood, GP ;
Gao, K ;
Gill, P ;
Huang, G ;
Klein, HA .
LASER FREQUENCY STABILIZATION, STANDARDS, MEASUREMENT AND APPLICATIONS, 2001, 4269 :134-142
[7]   Frequency Comparison of Two High-Accuracy Al+ Optical Clocks [J].
Chou, C. W. ;
Hume, D. B. ;
Koelemeij, J. C. J. ;
Wineland, D. J. ;
Rosenband, T. .
PHYSICAL REVIEW LETTERS, 2010, 104 (07)
[8]   EXPERIMENTAL STUDY OF ZEEMAN LIGHT SHIFTS IN WEAK MAGNETIC-FIELDS [J].
COHENTANNOUDJI, C ;
DUPONTRO.J .
PHYSICAL REVIEW A-GENERAL PHYSICS, 1972, 5 (02) :968-+
[9]   Electric quadrupole shift cancellation in single-ion optical frequency standards -: art. no. 033001 [J].
Dubé, P ;
Madej, AA ;
Bernard, JE ;
Marmet, L ;
Boulanger, JS ;
Cundy, S .
PHYSICAL REVIEW LETTERS, 2005, 95 (03)
[10]   High-Accuracy Measurement of the Differential Scalar Polarizability of a 88Sr+ Clock Using the Time-Dilation Effect [J].
Dube, Pierre ;
Madej, Alan A. ;
Tibbo, Maria ;
Bernard, John E. .
PHYSICAL REVIEW LETTERS, 2014, 112 (17)