Energy saving potential of heat insulation solar glass: Key results from laboratory and in-situ testing

被引:42
作者
Cuce, Erdem [1 ,2 ]
Cuce, Pinar Mert [1 ,3 ]
Young, Chin-Huai [1 ,4 ]
机构
[1] Univ Nottingham, Fac Engn, Dept Architecture & Built Environm, Univ Pk, Nottingham NG7 2RD, England
[2] Univ Bayburt, Dept Mech Engn, Fac Engn, TR-69000 Bayburt, Turkey
[3] Republ Turkey Minist Natl Educ, Ankara, Turkey
[4] Natl Taiwan Univ Sci & Technol, Dept Civil & Construct Engn, Taipei 106, Taiwan
关键词
Heat insulation solar glass; Heating and cooling demand; Energy saving; Thermal comfort; HOMOTOPY PERTURBATION METHOD; AEROGEL GLAZING SYSTEM; THERMAL SUPERINSULATION; PERFORMANCE; EFFICIENCY; BUILDINGS; TOMORROW; FACADES; IMPACT;
D O I
10.1016/j.energy.2015.12.134
中图分类号
O414.1 [热力学];
学科分类号
摘要
HISG (heat insulation solar glass) is a recently developed multi-functional glazing technology to mitigate energy consumption of buildings. HISG can generate electricity similar to conventional PV (photovoltaic) glazing products when exposed to sunlight, however it differs from them by having some extraordinary characteristic features such as thermal insulation, which is competitive with Argon filled triple glazed windows, acoustic comfort, remarkable energy saving potential and self-cleaning ability owing to TiO2 nano coating. Within the scope of this research, latest results from laboratory and in-situ testing of HISG are presented in terms of its key role in mitigating heating and cooling demand of buildings as well as clean energy generation. Lighting and thermal comfort related parameters such as shading coefficient, UV, IR and visible light intensity are also investigated through the tests conducted in real operating conditions. It is achieved from the results that instant electricity generation of HISG is 16% higher than that of standard PV glazing owing to its nano layer reflective film. Shading coefficient of HISG is only 0.136, which provides almost 80% reduction in solar heat gain compared to ordinary glazing. Indoor air temperature measured from HISG test house in summer time is very close to the ambient temperature, whereas it is found to be 14.7 degrees C higher in ordinary glass test house due to greenhouse effect. Annual heating and cooling demand tests indicate that HISG provides 38 and 48% energy saving in heating and cooling season, respectively. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:369 / 380
页数:12
相关论文
共 40 条
  • [1] A review on applications of ANN and SVM for building electrical energy consumption forecasting
    Ahmad, A. S.
    Hassan, M. Y.
    Abdullah, M. P.
    Rahman, H. A.
    Hussin, F.
    Abdullah, H.
    Saidur, R.
    [J]. RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 33 : 102 - 109
  • [2] Aerogel insulation for building applications: A state-of-the-art review
    Baetens, Ruben
    Jelle, Bjorn Petter
    Gustavsen, Arild
    [J]. ENERGY AND BUILDINGS, 2011, 43 (04) : 761 - 769
  • [3] Gas-filled panels for building applications: A state-of-the-art review
    Baetens, Ruben
    Jelle, Bjorn Petter
    Gustavsen, Arild
    Grynning, Steinar
    [J]. ENERGY AND BUILDINGS, 2010, 42 (11) : 1969 - 1975
  • [4] Experimental performance evaluation of aerogel glazing systems
    Buratti, C.
    Moretti, E.
    [J]. APPLIED ENERGY, 2012, 97 : 430 - 437
  • [5] Cuce E., 2015, INDOOR BUIL IN PRESS
  • [6] Cuce E., 2014, Ph.D. Thesis
  • [7] Cuce E., 2009, 4 INT EX EN ENV S 19
  • [8] Cuce E, 2010, 5 INT EG EN S EXH 27
  • [9] Aerogel-Assisted Support Pillars for Thermal Performance Enhancement of Vacuum Glazing: A CFD Research for a Commercial Product
    Cuce, Erdem
    Riffat, Saffa B.
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2015, 40 (08) : 2233 - 2238
  • [10] Thermal insulation, power generation, lighting and energy saving performance of heat insulation solar glass as a curtain wall application in Taiwan: A comparative experimental study
    Cuce, Erdem
    Riffat, Saffa B.
    Young, Chin-Huai
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 96 : 31 - 38