Development and evaluation of reaction gas chromatograph as a calibration method using an index compound

被引:1
作者
Watanabe, T [1 ]
Kato, K [1 ]
Matsumoto, N [1 ]
Maeda, T [1 ]
机构
[1] AIST Tsukuba Cent 3, Organ Analyt Chem Div, NMIJ, Tsukuba, Ibaraki 3058563, Japan
关键词
micro reactor; reaction gas chromatography; GC/MS; hydrogenation; hydrodechlorination; calibration method; index compound;
D O I
10.2116/bunsekikagaku.52.265
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to realize a technique that serves as a calibration method using an index compound, reaction gas chromatography was examined. An index compound represents a group which includes many compounds; compounds in this group can be calibrated using the index compound. The gas chromatograph/micro reactor/mass spectrometer (GC/MR/MS) consists of a capillary gas chromatograph/mass spectrometer and a micro reactor. By using the MR, alkenes and alkynes were transformed to alkanes having the same carbon skeleton. Ethylene in a cylinder was determined using ethane as an index compound. The results showed good agreement with a reference value. The hydrodechlorination of chlorobenzenes was examined. Chlorobenzene in a solution was determined by using benzene as an index compound. The experimental results and reference concentration showed a good agreement. The efficacy of this technique was demonstrated with these results.
引用
收藏
页码:265 / 268
页数:4
相关论文
共 39 条
[31]   Development of a screening method for the analysis of organic pollutants in water using dual stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry [J].
Toelgyessy, Peter ;
Vrana, Branislav ;
Krascsenits, Zoltan .
TALANTA, 2011, 87 :152-160
[32]   Development of an Untargeted Method for the Analysis of the Volatile Profile of Onions via Solid-Phase Microextraction Arrow-Headspace-Gas Chromatography-Mass Spectrometry Using Design of Experiments [J].
Boeckstiegel, Lea ;
Schaumann, Theresa ;
Egert, Bjoern ;
Kulling, Sabine E. ;
Weinert, Christoph H. .
JOURNAL OF SEPARATION SCIENCE, 2024, 47 (19)
[33]   Optimization of the derivatization reaction and the solid-phase microextraction conditions using a D-optimal design and three-way calibration in the determination of non-steroidal anti-inflammatory drugs in bovine milk by gas chromatography-mass spectrometry [J].
Arroyo, David ;
Ortiz, M. Cruz ;
Sarabia, Luis A. .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (28) :4487-4497
[34]   Assessment of human exposure to PCDDs, PCDFs and Co-PCBs using hair as a human pollution indicator sample 1: development of analytical method for human hair and evaluation for exposure assessment [J].
Nakao, T ;
Aozasa, O ;
Ohta, S ;
Miyata, H .
CHEMOSPHERE, 2002, 48 (08) :885-896
[35]   The development of a novel, green, efficient, and eco-friendly GC-MS/MS analytical method for the reliable and rapid determination of dl-PCBs, and PCDD/Fs using hydrogen as a carrier gas and a modified ion source [J].
Cetinturk, Kartal ;
Guzel, Baris ;
Canli, Oltan .
TALANTA, 2025, 283
[36]   Development of a large volume injection method using a programmed temperature vaporization injector - gas chromatography hyphenated to ICP-MS for the simultaneous determination of mercury, tin and lead species at ultra-trace levels in natural waters [J].
Teran-Baamonde, J. ;
Bouchet, S. ;
Tessier, E. ;
Amouroux, D. .
JOURNAL OF CHROMATOGRAPHY A, 2018, 1547 :77-85
[37]   Development of a sensitive and accurate method for the simultaneous determination of selected insecticides and herbicide in tap water and wastewater samples using vortex-assisted switchable solvent-based liquid-phase microextraction prior to determination by gas chromatography-mass spectrometry [J].
Bozyigit, Gamze Dalgic ;
Ayyildiz, Merve Firat ;
Chormey, Dotse Selali ;
Engin, Guleda Onkal ;
Bakirdere, Sezgin .
ENVIRONMENTAL MONITORING AND ASSESSMENT, 2020, 192 (05)
[38]   Development of a sensitive and accurate method for the simultaneous determination of selected insecticides and herbicide in tap water and wastewater samples using vortex-assisted switchable solvent-based liquid-phase microextraction prior to determination by gas chromatography-mass spectrometry [J].
Gamze Dalgıç Bozyiğit ;
Merve Fırat Ayyıldız ;
Dotse Selali Chormey ;
Guleda Onkal Engin ;
Sezgin Bakırdere .
Environmental Monitoring and Assessment, 2020, 192
[39]   Method development and validation for the determination of 2,4,6-tribromoanisole, 2,4,6-tribromophenol, 2,4,6-trichloroanisole, and 2,4,6-trichlorophenol in various drug products using stir bar sorptive extraction and gas chromatography-tandem mass spectrometry detection [J].
Huang, Jiun-Tang ;
Alquier, Lori ;
Kaisa, Joyce P. ;
Reed, Gail ;
Gilmor, Timothy ;
Vas, Gyorgy .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1262 :196-204