Development and evaluation of reaction gas chromatograph as a calibration method using an index compound

被引:1
作者
Watanabe, T [1 ]
Kato, K [1 ]
Matsumoto, N [1 ]
Maeda, T [1 ]
机构
[1] AIST Tsukuba Cent 3, Organ Analyt Chem Div, NMIJ, Tsukuba, Ibaraki 3058563, Japan
关键词
micro reactor; reaction gas chromatography; GC/MS; hydrogenation; hydrodechlorination; calibration method; index compound;
D O I
10.2116/bunsekikagaku.52.265
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to realize a technique that serves as a calibration method using an index compound, reaction gas chromatography was examined. An index compound represents a group which includes many compounds; compounds in this group can be calibrated using the index compound. The gas chromatograph/micro reactor/mass spectrometer (GC/MR/MS) consists of a capillary gas chromatograph/mass spectrometer and a micro reactor. By using the MR, alkenes and alkynes were transformed to alkanes having the same carbon skeleton. Ethylene in a cylinder was determined using ethane as an index compound. The results showed good agreement with a reference value. The hydrodechlorination of chlorobenzenes was examined. Chlorobenzene in a solution was determined by using benzene as an index compound. The experimental results and reference concentration showed a good agreement. The efficacy of this technique was demonstrated with these results.
引用
收藏
页码:265 / 268
页数:4
相关论文
共 38 条
  • [21] Development and validation of gas chromatography-mass spectroscopy method for determination of prilocaine HCl in human plasma using internal standard methodology
    Kadioglu, Yucel
    Atila, Alptug
    [J]. BIOMEDICAL CHROMATOGRAPHY, 2007, 21 (10) : 1077 - 1082
  • [22] Development of a Dispersive Liquid-Liquid Microextraction Method for Quantification of Volatile Compounds in Wines Using Gas Chromatography-Mass Spectrometry
    Appuhamilage, Dinesha Katugampala
    Jelley, Rebecca E.
    Sherman, Emma
    Pilkington, Lisa I.
    Pinu, Farhana R.
    Fedrizzi, Bruno
    [J]. METABOLITES, 2025, 15 (02)
  • [23] Quantification of F2-isoprostanes as a reliable index of oxidative stress in vivo using gas chromatography-mass spectrometry (GC-MS) method
    Liu, Wei
    Morrow, Jason D.
    Yin, Huiyong
    [J]. FREE RADICAL BIOLOGY AND MEDICINE, 2009, 47 (08) : 1101 - 1107
  • [24] Development of a solid phase microextraction-gas chromatography-mass spectrometry method for the determination of pentachlorophenol in human plasma using experimental design
    Zhou, Ying
    Jiang, Qingwu
    Peng, Qian
    Xuan, Dongliang
    Qu, Weidong
    [J]. CHEMOSPHERE, 2007, 70 (02) : 256 - 262
  • [25] Development of multi-response optimization and quadratic calibration curve for determination of ten pesticides in complex sample matrices using QuEChERS dispersive liquid-liquid microextraction followed by gas chromatography
    Balsini, Parvaneh
    Parastar, Hadi
    [J]. JOURNAL OF SEPARATION SCIENCE, 2019, 42 (23) : 3553 - 3562
  • [26] Development of an analytical method of organochlorine pesticides in human bloods using head space-solid phase microextraction coupled with gas chromatography/mass spectrometry
    Kang, Tae-woo
    Pyo, Hee-soo
    Hong, Jongki
    [J]. ANALYTICAL SCIENCE AND TECHNOLOGY, 2008, 21 (04) : 259 - 271
  • [27] Evaluation of the effectiveness of a high-speed method of screening phthalate esters in polymers using pyrolyzer/thermal desorption-gas chromatography-mass spectrometry
    Kudo, Yukihiko
    Chu, Xue
    Tanaka, Koki
    Uchimura, Tomohiro
    [J]. JOURNAL OF CHROMATOGRAPHY OPEN, 2022, 2
  • [28] Development and validation of a solid-phase extraction method using anion exchange sorbent for the analysis of cannabinoids in plasma and serum by gas chromatography-mass spectrometry
    Gasse, Angela
    Pfeiffer, Heidi
    Koehler, Helga
    Schuerenkamp, Jennifer
    [J]. INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2016, 130 (04) : 967 - 974
  • [29] An improved quantification method for 12 linear dimethylsiloxanes and 1 cyclic dimethylsiloxane in polydimethylsiloxane using gas chromatography-flame ionization detector:Development strategy and accuracy
    Feng, Jinglan
    Zhang, Fei
    Zhao, Jiahui
    Guo, Wei
    Sun, Jianhui
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2018, 1578 : 112 - 116
  • [30] Development of a screening method for the analysis of organic pollutants in water using dual stir bar sorptive extraction-thermal desorption-gas chromatography-mass spectrometry
    Toelgyessy, Peter
    Vrana, Branislav
    Krascsenits, Zoltan
    [J]. TALANTA, 2011, 87 : 152 - 160