Track etch velocity study in a radon detector (LR 115, cellulose nitrate)

被引:40
|
作者
Barillon, R [1 ]
Fromm, M
Chambaudet, A
Marah, H
Sabir, A
机构
[1] Univ Franche Comte, UFR Sci & Tech, Lab Microanal Nucl, F-25030 Besancon, France
[2] Univ IBN Tofail, Fac Sci, Nucl Phys Lab, Kenitra, Morocco
关键词
LR; 115; etching; track etch velocity; radon; detection efficiency;
D O I
10.1016/S1350-4487(97)00153-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
For radon dosimetry, complete knowledge of the detection area of the detector used for alpha particles emitted by radon and its two daughters (Po 218 and Po 214) is compulsory. Latent tracks in the detector induced by alpha particles are enlarged in a hot hydroxide sodium bath to make them observable by microscopy. This paper deals with the determination of the track etch velocity (V-T). We compared two different approaches to calculate the V-T: for the first one, the V-T is considered as a function of the alpha particle energy. The V-T is determined by using a track etch model based on the experimental study of the track diameters for normal incidence versus alpha particle energies. For the second approach, we assumed that the V-T was directly correlated with the ionisation rate (I) created all along the alpha particle range in the detector. This ionisation rate, which depends directly on the alpha particle energy was calculated using the TRIM programme. The knowledge of the V-T enabled us to determine the critical incidence angle for each energy under which the alpha particle did not induce an observable track Results for each approach were compared with the experimental data obtained with a specific irradiator system. Finally, track detection efficiencies of LR 115 for radon and their standard deviations are proposed for a simple configuration.
引用
收藏
页码:619 / 628
页数:10
相关论文
共 36 条
  • [1] Track etch velocity and chemical damages induced by ions in a cellulose nitrate detector
    Barillon, R
    RADIATION MEASUREMENTS, 2005, 40 (2-6) : 214 - 217
  • [2] The calibration of the solid state nuclear track detector LR 115 for radon measurements
    Gericke, C
    Ghose, R
    Jönsson, G
    Freyer, K
    Treutler, HC
    Enge, W
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 363 - 366
  • [3] Effects of stirring on the bulk etch rate of LR 115 detector
    Yip, CWY
    Ho, JPY
    Koo, VSY
    Nikezic, D
    Yu, KN
    RADIATION MEASUREMENTS, 2003, 37 (03) : 197 - 200
  • [4] Performance evaluation of a new reading technique of LR115 cellulose nitrate track detectors
    Caresana, M.
    Ferrarini, M.
    RADIATION MEASUREMENTS, 2010, 45 (08) : 911 - 915
  • [5] Evaluation of Efficiency Calibration Parameters of the LR-115 Radon Detector
    Mireles, F.
    Davila, J. I.
    Garcia-Betancourt, M. L.
    Pinedo, J. L.
    Lopez, H.
    HEALTH PHYSICS, 2010, 98 (05): : S63 - S68
  • [6] Parallel track-etch detector arrangement for radon measurement in soil
    Turek, K
    Bednar, J
    Neznal, M
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 751 - 754
  • [7] Response of diffusion chamber with LR115 detector and electret to radon and progeny
    University of Kragujevac, Faculty of Science, R. Domanovic 12, 34000 Kragujevac, Serbia
    Radiat. Meas., 2009, 9-10 (783-786):
  • [8] Theoretical and experimental study of the LR-115 detector response in a non-commercial radon monitor
    Perez, B.
    Lopez, M. E.
    Palacios, D.
    APPLIED RADIATION AND ISOTOPES, 2020, 160
  • [9] Design of a radon measuring device based on the diffusion principle using LR 115 detector
    Djeffal, S
    Lounis, Z
    Allab, M
    RADIATION MEASUREMENTS, 1997, 28 (1-6) : 629 - 632
  • [10] Bond scission cross sections for α-particles in cellulose nitrate (LR115)
    Barillon, R
    Fromm, M
    Chambaudet, A
    Katz, R
    Stoquert, JP
    Pape, A
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 71 - 75