Effect of Pulse Energy, Frequency and Length on Holmium: Yttrium-Aluminum-Garnet Laser Fragmentation Efficiency in Non-Floating Artificial Urinary Calculi

被引:47
作者
Wezel, Felix [1 ]
Haecker, Axel [1 ]
Gross, Andreas J. [2 ]
Michel, Maurice Stephan [1 ]
Bach, Thorsten [1 ,2 ]
机构
[1] Univ Med Ctr Mannheim, Dept Urol, D-68167 Mannheim, Germany
[2] Asklepios Hosp Barmbek, Dept Urol, Hamburg, Germany
关键词
ND-YAG LASER; IN-VITRO; TRANSIENT CAVITATION; STONE RETROPULSION; ACOUSTIC-EMISSION; URETERAL CALCULI; LITHOTRIPSY; MANAGEMENT; URETERORENOSCOPY; URETEROSCOPY;
D O I
10.1089/end.2010.0115
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and Purpose: Holmium: yttrium-aluminum-garnet (Ho:YAG) laser lithotripsy is the standard lithotrite in ureteroscopy. We investigated the influence of pulse frequency, energy and length on the fragmentation efficiency of Ho: YAG laser lithotripsy in non-floating artificial stones in vitro. Materials and Methods: Stone fragmentation efficiency of three different Ho: YAG laser devices were evaluated in vitro at different pulse energy (1.0 and 2.0 J) and frequency settings (5 and 10 Hz), resulting in a standardized output power of 10W, respectively. Where possible, pulse length was modified (350 vs 700 mu sec). Each setting was performed with a 273 mm and a 365 mm fiber. Lithotripsy was conducted using non-repulsive stones consisting of soft stone (plaster of Paris) and hard stone composition (Fujirock type 4). Results: Our results showed an increased stone disintegration efficiency at higher pulse energy (2.0 J/5 Hz vs 1.0 J/10 Hz) independently of two fiber diameters and stone types applied in this study (P < 0.05 in 18 of 20 groups). Similarly, reduction of the pulse length from 700 to 350 msec resulted in a higher stone disintegration (P < 0.05 in 13 of 16 groups). This effect was most prominent when applied to soft stones. Higher fiber diameter was not constantly associated with an increase in stone disintegration. Conclusion: We demonstrate that an increase of pulse energy and a reduction of pulse length at a standardized output power of 10W can improve Ho: YAG laser fragmentation efficiency in vitro in nonfloating stones. These results may potentially affect clinical practice ofHo:YAGlaser lithotripsy in impacted or large stones, whenretropulsion is excluded.
引用
收藏
页码:1135 / 1140
页数:6
相关论文
共 30 条
[11]   Stone retropulsion during holmium:yag lithotripsy [J].
Lee, H ;
Ryan, RT ;
Teichman, JMH ;
Kim, J ;
Choi, B ;
Arakeri, NV ;
Welch, AJ .
JOURNAL OF UROLOGY, 2003, 169 (03) :881-885
[12]   In vitro evaluation of nitinol urological retrieval coil and ureteral occlusion device: Retropulsion and holmium laser fragmentation efficiency [J].
Lee, Hak J. ;
Box, Geoffrey N. ;
Abraham, Jose Benito A. ;
Deane, Leslie A. ;
Elchico, Erick R. ;
Eisner, Brian H. ;
McDougall, Elspeth M. ;
Clayman, Ralph V. .
JOURNAL OF UROLOGY, 2008, 180 (03) :969-973
[13]   Changing Trends in the Use of Ureteroscopic Instruments from 1996 to 2008 [J].
Leone, Nicholas T. ;
Garcia-Roig, Michael ;
Bagley, Demetrius H. .
JOURNAL OF ENDOUROLOGY, 2010, 24 (03) :361-365
[14]   Intracorporeal lithotripsy: which modality is best? [J].
Leveillee, RJ ;
Lobik, L .
CURRENT OPINION IN UROLOGY, 2003, 13 (03) :249-253
[15]   In vitro comparison of stone retropulsion and fragmentation of the frequency doubled, double pulse Nd:Yag laser and the holmium:Yag laser [J].
Marguet, CG ;
Sung, JC ;
Springhart, WP ;
L'Esperance, JO ;
Zhou, SL ;
Zhong, P ;
Albala, DM ;
Preminger, GM .
JOURNAL OF UROLOGY, 2005, 173 (05) :1797-1800
[16]   Ultracal-30 gypsum artificial stones for research on the mechanisms of stone breakage in shock wave lithotripsy [J].
McAteer, JA ;
Williams, JC ;
Cleveland, RO ;
Van Cauwelaert, J ;
Bailey, MR ;
Lifshitz, DA ;
Evan, AP .
UROLOGICAL RESEARCH, 2005, 33 (06) :429-434
[17]   Flexible ureterorenoscopy for the treatment of lower pole calyx stones:: Influence of different lithotripsy probes and stone extraction tools on scope deflection and irrigation flow [J].
Michel, MS ;
Knoll, T ;
Ptaschnyk, T ;
Köhrmann, KU ;
Alken, P .
EUROPEAN UROLOGY, 2002, 41 (03) :312-316
[18]   Operative failure during ureteroscopic pneumatic lithotripsy: Factors affecting successful outcome [J].
Miroglu, Cengiz ;
Horasanli, Kaya ;
Tanriverdi, Orhan ;
Altay, Bulent ;
Gumus, Eyup .
UROLOGIA INTERNATIONALIS, 2006, 77 (02) :148-151
[19]   Evaluation of 24 Holmium:YAG Laser Optical Fibers for Flexible Ureteroscopy [J].
Mues, Adam C. ;
Teichman, Joel M. H. ;
Knudsen, Bodo E. .
JOURNAL OF UROLOGY, 2009, 182 (01) :348-354
[20]   Review of laser fibers: A practical guide for urologists [J].
Nazif, OA ;
Teichman, JMH ;
Glickman, RD ;
Welch, AJ .
JOURNAL OF ENDOUROLOGY, 2004, 18 (09) :818-829