Artifact-free volume clipping algorithm for real-time 3D ultrasound

被引:0
|
作者
Karadayi, Kerern [1 ,2 ]
Shamdasani, Vijay [1 ,2 ]
Managuli, Ravi [1 ,2 ,3 ]
Kim, Yongmin [1 ,2 ]
机构
[1] Univ Washington, Image Comp Syst Lab, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Image Comp Syst Lab, Dept Elect Engn, Seattle, WA 98195 USA
[3] Hitachi Med Syst Amer, Twinsburg, OH 44087 USA
来源
MEDICAL IMAGING 2007: ULTRASONIC IMAGING AND SIGNAL PROCESSING | 2007年 / 6513卷
关键词
3D ultrasound; image quality; ultrasound volume visualization; volume clipping;
D O I
10.1117/12.711554
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Three-dimensional (313) ultrasound has become a useful tool in cardiac imaging, OB/GYN and other clinical applications. It enables clinicians to visualize the acquired volume and/or planes that are not easily accessible using 2D ultrasound, in addition to providing an intuitive understanding of the structural anatomy in three dimensions. One effective way to examine the acquired volumetric data is by clipping away parts of the volume using cross-sectional cuts to reveal the underlying anatomy masked by other structures. Ideally, such boundaries should reflect the orientation and location of the clip surfaces without altering the information content of the original data. Because of the artificial surface introduced by the clip boundary, shading employed to enhance the surfaces of the object gets modified, resulting in inconsistent shading and noticeable artifacts in the case of ultrasound data. Consistent shading of clip surfaces was previously studied for graphics hardware-based volume rendering, and an algorithm was developed and demonstrated in MRI, CT and non-medical datasets. However, that algorithm cannot be applied directly to fast software-based rendering approaches such as the shear-warp algorithm. Furthermore, ultrasound data require a different clipping approach due to their fuzzy nature, lower signal-to-noise ratios, and real-time requirements. In this paper, we present a software-based volume clipping technique that can effectively and efficiently overcome the difficulties associated with the shading of the clip boundaries in ultrasound data using shear-warp. Our technique improves the viewer's comprehension of the clip boundary without altering the original information content within the volume. The method has been implemented on programmable processors while maintaining the interactive speed in rendering.
引用
收藏
页数:11
相关论文
共 6 条
  • [1] Real-time ray casting rendering of volume clipping in medical visualization
    Chen, W
    Hua, W
    Bao, HJ
    Peng, QS
    JOURNAL OF COMPUTER SCIENCE AND TECHNOLOGY, 2003, 18 (06) : 804 - 814
  • [2] Real-time ray casting rendering of volume clipping in medical visualization
    Wei Chen
    Wei Hua
    HuJun Bao
    QunSheng Peng
    Journal of Computer Science and Technology, 2003, 18 : 804 - 814
  • [3] Integration of free-hand 3D ultrasound and mobile C-arm cone-beam CT: Feasibility and characterization for real-time guidance of needle insertione
    Marinetto, E.
    Uneri, A.
    De Silva, T.
    Reaungamornrat, S.
    Zbijewski, W.
    Sisniega, A.
    Vogt, S.
    Kleinszig, G.
    Pascau, J.
    Siewerdsen, J. H.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2017, 58 : 13 - 22
  • [4] Rapid scalar value classification and volume clipping for interactive 3D medical image visualization
    Zhang, Qi
    Eagleson, Roy
    Peters, Terry M.
    VISUAL COMPUTER, 2011, 27 (01): : 3 - 19
  • [5] Rapid scalar value classification and volume clipping for interactive 3D medical image visualization
    Qi Zhang
    Roy Eagleson
    Terry M. Peters
    The Visual Computer, 2011, 27 : 3 - 19
  • [6] Adaptive glasses-free 3D display with extended continuous viewing volume by dynamically configured directional backlight
    Li, Xiaoke
    Ding, Juan
    Zhang, Hantao
    Chen, Mingjun
    Liang, Weitang
    Wang, Shuying
    Fan, Hang
    Li, Kunyang
    Zhou, Jianying
    OSA CONTINUUM, 2020, 3 (06) : 1555 - 1567