Variable-window algorithm for ultra-high-speed distance protection

被引:12
作者
Fazio, G [1 ]
Lauropoli, V
Muzi, F
Sacerdoti, G
机构
[1] Univ Roma Tor Vergata, Dept Elect Engn, Rome, Italy
[2] ACEA SpA, Rome Water & Elect Util, Rome, Italy
[3] Univ Laquila, Dept Elect Engn, Laquila, Italy
[4] Univ Roma La Sapienza, Dept Elect Engn, Rome, Italy
关键词
computer relaying; distance protection; transmission and distribution systems;
D O I
10.1109/TPWRD.2002.807159
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new concept in ultra-high speed distance relay for power line protection. The idea is based on the use of a sampling window shorter than usual to speed commutation. The reduction in protection time is obtained through a variable window that is expanded sample by sample until a satisfactory precision is reached in the calculation of fault quantities. The right window length is obtained automatically via software and time-by-time changes depending on the characteristics of the fault. The algorithm is based on the equation associated to the R-L fault circuit, whose solution is obtained using the phase modified Fourier transform. To validate the proposed procedure, a large number of simulations are performed with reference to an existing 150-kV subtransmission line. In comparison with other solutions, the relay proposed here is very cost-effective and makes it possible to achieve ultra-high speed fault localization not only on high-voltage (HV) networks but also on medium-voltage (MV) distribution networks.
引用
收藏
页码:412 / 419
页数:8
相关论文
共 14 条
[1]  
CLAUS M, 1997, P I ELECT ENG PUBL, V434, P28
[2]   PERFORMANCE ANALYSIS OF TRANSIENT DETECTORS BASED ON A CLASS OF LINEAR DATA TRANSFORMS [J].
FRIEDLANDER, B ;
PORAT, B .
IEEE TRANSACTIONS ON INFORMATION THEORY, 1992, 38 (02) :665-673
[3]  
*IEEE, 1997, ADV MICR BAS PROT CO, pCH3
[4]  
JOHNSON DA, 1983, GENE ANAL TECH, V1, P3
[5]  
KENNEDY JM, VARIABLE DIGITAL FIL
[6]   EXPERIMENTAL EVALUATION OF EMTP-BASED CURRENT TRANSFORMER MODELS FOR PROTECTIVE RELAY TRANSIENT STUDY [J].
KEZUNOVIC, M ;
KOJOVIC, L ;
ABUR, A ;
FROMEN, CW ;
SEVCIK, DR ;
PHILLIPS, F .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) :405-412
[7]   Distance relay application testing using a digital simulator [J].
Kezunovic, M ;
Xia, YQ ;
Guo, Y ;
Fromen, CW ;
Sevcik, DR .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (01) :72-82
[8]  
MATHEWS CA, 1980, P I ELECT ENG PUBL, V185
[9]  
MUZI F, 1999, IEEE POW ENG SOC 199
[10]  
Phadke G., 1988, COMPUTER RELAYING PO