Estimation and Validation of Arterial Blood Pressure Using Photoplethysmogram Morphology Features in Conjunction With Pulse Arrival Time in Large Open Databases

被引:34
作者
Yang, Seungman [1 ]
Sohn, Jangjay [1 ]
Lee, Saram [2 ]
Lee, Joonnyong [3 ]
Kim, Hee Chan [4 ,5 ]
机构
[1] Seoul Natl Univ, Grad Sch, Interdisciplinary Program Bioengn, Seoul 08826, South Korea
[2] Seoul Natl Univ Hosp, Biomed Res Inst, Seoul 03080, South Korea
[3] Mellowing Factory Co Ltd, Seoul 03726, South Korea
[4] Seoul Natl Univ, Coll Med, Dept Biomed Engn, Seoul 03080, South Korea
[5] Seoul Natl Univ, Med Res Ctr, Inst Med & Biol Engn, Seoul 08826, South Korea
基金
新加坡国家研究基金会;
关键词
Estimation; Morphology; Databases; Feature extraction; Electrocardiography; Biological system modeling; Monitoring; Continuous blood pressure monitoring; biosignal database; photoplethysmogram morphology; feature selection; pulse arrival time; TRANSIT-TIME; ALGORITHMS; STIFFNESS; SELECTION; HEALTH;
D O I
10.1109/JBHI.2020.3009658
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Although various predictors and methods for BP estimation have been proposed, differences in study designs have led to difficulties in determining the optimal method. This study presents analyses of BP estimation methods using 2.4 million cardiac cycles of two commonly used non-invasive biosignals, electrocardiogram (ECG) and photoplethysmogram (PPG), from 1376 surgical patients. Feature selection methods were used to determine the best subset of predictors from a total of 42 including PAT, heart rate (HR), and various PPG morphology features, and BP estimation models constructed using linear regression (LR), random forest (RF), artificial neural network (ANN), and recurrent neural network (RNN) were evaluated. 28 features out of 42 were determined as suitable for BP estimation, in particular two PPG morphology features outperformed PAT, which has been conventionally seen as the best non-invasive indicator of BP. By modelling the low frequency component of BP using ANN and the high frequency component using RNN with the selected predictors, mean errors of 0.05 +/- 6.92 mmHg for systolic BP, and -0.05 +/- 3.99 mmHg for diastolic BP were achieved. External validation of the model using another biosignal database consisting of 334 intensive care unit patients led to similar results, satisfying three standards for accuracy of BP monitors. The results indicate that the proposed method can contribute to the realization of ubiquitous non-invasive continuous BP monitoring.
引用
收藏
页码:1018 / 1030
页数:13
相关论文
共 73 条
[51]  
OBrien E., 1993, J HYPERTENS, V11, pS43
[52]   A REAL-TIME QRS DETECTION ALGORITHM [J].
PAN, J ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) :230-236
[53]   Feature selection based on mutual information: Criteria of max-dependency, max-relevance, and min-redundancy [J].
Peng, HC ;
Long, FH ;
Ding, C .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2005, 27 (08) :1226-1238
[54]  
Peng Su, 2018, 2018 IEEE EMBS International Conference on Biomedical & Health Informatics (BHI), P323, DOI 10.1109/BHI.2018.8333434
[55]   A review of methods for non-invasive and continuous blood pressure monitoring: Pulse transit time method is promising? [J].
Peter, L. ;
Noury, N. ;
Cerny, M. .
IRBM, 2014, 35 (05) :271-282
[56]   WHAT IS THE ROLE OF AMBULATORY BLOOD-PRESSURE MONITORING IN THE MANAGEMENT OF HYPERTENSIVE PATIENTS [J].
PICKERING, TG ;
HARSHFIELD, GA ;
DEVEREUX, RB ;
LARAGH, JH .
HYPERTENSION, 1985, 7 (02) :171-177
[57]   Cuff-less and noninvasive measurements of arterial blood pressure by pulse transit time [J].
Poon, C. C. Y. ;
Zhang, Y. T. .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :5877-5880
[58]   Is Pulse Transit Time a good indicator of Blood Pressure changes during short physical exercise in a young population? [J].
Proenca, Jorge ;
Muehlsteff, Jens ;
Aubert, Xavier ;
Carvalho, Paulo .
2010 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2010, :598-601
[59]  
Putyatina YS, 2002, SIBERIAN RUSSIAN WORKSHOPS AND TUTORIALS ON ELECTRON DEVICES AND MATERIALS, EDM 2002, VOL 2, PROCEEDINGS, P77
[60]   Estimating blood pressure trends and the nocturnal dip from photoplethysmography [J].
Radha, Mustafa ;
de Groot, Koen ;
Rajani, Nikita ;
Wong, Cybele C. P. ;
Kobold, Nadja ;
Vos, Valentina ;
Fonseca, Pedro ;
Mastellos, Nikolaos ;
Wark, Petra A. ;
Velthoven, Nathalie ;
Haakma, Reinder ;
Aarts, Ronald M. .
PHYSIOLOGICAL MEASUREMENT, 2019, 40 (02)