Planar amperometric glucose sensor based on glucose oxidase immobilized by chitosan film on Prussian blue layer

被引:71
|
作者
Zhu, JH [1 ]
Zhu, ZQ
Lai, ZS
Wang, R
Guo, XM
Wu, XQ
Zhang, GX
Zhang, ZR
Zhang, ZR
Wang, YT
Chen, ZY
机构
[1] E China Normal Univ, IT Coll, Shanghai 200062, Peoples R China
[2] Shanghai Teachers Univ, Shanghai 2000234, Peoples R China
[3] Shanghai Inst Med Control, Shanghai 200233, Peoples R China
[4] Fudan Univ, Dept Surg, Huashan Hosp, Shanghai 200040, Peoples R China
来源
SENSORS | 2002年 / 2卷 / 04期
关键词
Prussian Blue; electrocatalysis; chitosan; selective permeability; glucose sensor;
D O I
10.3390/s20400127
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A planar amperometric glucose microsensor based on glucose oxidase immobilized by chitosan film on Prussian Blue layer has been developed. The experimental results show that the optimum detection potential is 50 mV ( versus Ag/AgCl) and the optimum pH is 6.5. Under the selective conditions the sensor exhibits excellent sensitivity of 98 nA/M and a linear range of 0.1-6.0 mM. The apparent Michanelis-Menten constant of the sensor is 21 mM. The response time is less than 60 seconds. No apparent change in the response to glucose was observed during one month. Foremost, the interference of ascorbic and uric acids can be avoided due to selective permeability of chitosan film and electrocatalysis of PB layer to H2O2. The sensor has been applied to detect glucose in human blood serum.
引用
收藏
页码:127 / 136
页数:10
相关论文
共 50 条
  • [31] Layer-by-layer assemblies of chitosan/multi-wall carbon nanotubes and glucose oxidase for amperometric glucose biosensor applications
    Wu, Bao-Yan
    Hou, Shi-Hua
    Yu, Min
    Qin, Xia
    Li, Sha
    Chen, Qiang
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2009, 29 (01): : 346 - 349
  • [32] An amperometric cholesterol biosensor based on cholesterol oxidase immobilized in polypyrrole on a Prussian blue modified electrode
    Li, JP
    Peng, TZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (06) : 669 - 673
  • [33] Glucose biosensor based on glucose oxidase immobilized in electropolymerized polypyrrole and poly(o-phenylenediamine) films on a Prussian Blue-modified electrode
    Garjonyte, R
    Malinauskas, A
    SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (1-2) : 122 - 128
  • [34] Biosensor composed of integrated glucose oxidase with liposome microreactors/chitosan nanocomposite for amperometric glucose sensing
    Guan Huanan
    Gong Dezhuang
    Song Yan
    Han Bolin
    Zhang Na
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2019, 574 : 260 - 267
  • [35] Prussian Blue-Based Flexible Thin Film Nanoarchitectonics for Non-enzymatic Electrochemical Glucose Sensor
    Elif Muslu
    Esin Eren
    Aysegul Uygun Oksuz
    Journal of Inorganic and Organometallic Polymers and Materials, 2022, 32 : 2843 - 2852
  • [36] Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode
    Wu, Bao-Yan
    Hou, Shi-Hua
    Yin, Feng
    Li, Jing
    Zhao, Zi-Xia
    Huang, Jia-Dong
    Chen, Qiang
    BIOSENSORS & BIOELECTRONICS, 2007, 22 (06) : 838 - 844
  • [37] New nanocomposite based on prussian blue nanoparticles/carbon nanotubes/chitosan and its application for assembling of amperometric glucose biosensor
    Zhai, XR
    Wei, WZ
    Zeng, JX
    Liu, XY
    Gong, SG
    ANALYTICAL LETTERS, 2006, 39 (05) : 913 - 926
  • [38] Amperometric glucose biosensor based on immobilization of glucose oxidase in chitosan matrix cross-linked with glutaraldehyde
    Miao, Y
    Chia, LS
    Goh, NK
    Tan, SN
    ELECTROANALYSIS, 2001, 13 (04) : 347 - 349
  • [39] Fabrication of Amperometric Glucose Sensor Using Glucose Oxidase-Cellulose Nanofiber Aqueous Solution
    Yasuzawa, Mikito
    Omura, Yuya
    Hiura, Kentaro
    Li, Jiang
    Fuchiwaki, Yusuke
    Tanaka, Masato
    ANALYTICAL SCIENCES, 2015, 31 (11) : 1111 - 1114
  • [40] Amperometric glucose biosensor based on silver nanowires and glucose oxidase
    Wang, Lisha
    Gao, Xia
    Jin, Lingyan
    Wu, Qi
    Chen, Zhichun
    Lin, Xianfu
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 176 : 9 - 14