High-voltage testing of a 500-kV dc photocathode electron gun

被引:22
|
作者
Nagai, Ryoji [1 ]
Hajima, Ryoichi [1 ]
Nishimori, Nobuyuki [1 ]
Muto, Toshiya [2 ]
Yamamoto, Masahiro [2 ]
Honda, Yosuke [2 ]
Miyajima, Tsukasa [2 ]
Iijima, Hokuto [3 ]
Kuriki, Masao [3 ]
Kuwahara, Makoto [4 ]
Okumi, Shoji [4 ]
Nakanishi, Tsutomu [4 ]
机构
[1] JAEA, Tokai, Ibaraki 3191195, Japan
[2] High Energy Accelerator Res Org, Tsukuba, Ibaraki 3050801, Japan
[3] Hiroshima Univ, Hiroshima 7398530, Japan
[4] Nagoya Univ, Aichi 4648601, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2010年 / 81卷 / 03期
关键词
ceramic insulators; electron guns; photocathodes; ENERGY RECOVERY LINACS; FIELD-EMISSION; ERL; PERSPECTIVES; INSULATION;
D O I
10.1063/1.3354980
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A high-voltage dc photocathode electron gun was successfully conditioned up to a voltage of 550 kV and a long-time holding test for 8 h was demonstrated at an acceleration voltage of 500 kV. The dc photocathode electron gun is designed for future light sources based on energy-recovery linac and consists of a Cockcroft-Walton generator, a segmented cylindrical ceramic insulator, guard-ring electrodes, a support-rod electrode, a vacuum chamber, and a pressurized insulating gas tank. The segmented cylindrical ceramic insulator and the guard-ring electrodes were utilized to prevent any damage to the insulator from electrons emitted by the support-rod electrode.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Photocathode lifetime improvement by using a pulsed high voltage on the photocathode gun of the polarized electron source at NIKHEF
    van den Putte, MJJ
    de Jager, CW
    Militsyn, BL
    Shatunov, YM
    Tokarev, YF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (01): : 50 - 52
  • [22] HIGH-VOLTAGE LONG-FOCUS ELECTRON-GUN
    VENIAMINOV, NN
    KUZAKOV, AK
    RAMBIDI, NG
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1982, 25 (06) : 1433 - 1435
  • [23] HIGH-VOLTAGE LONG-FOCUS ELECTRON GUN.
    Veniaminov, N.N.
    Kuzakov, A.K.
    Rambidi, N.G.
    Instruments and experimental techniques New York, 1982, 25 (6 pt 2): : 1433 - 1435
  • [24] HIGH-VOLTAGE TELEFOCUS ELECTRON-GUN WITH REMOTE FOCUSING
    SCHMORANZER, H
    WELLENSTEIN, HF
    BONHAM, RA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1975, 46 (01): : 89 - 91
  • [25] DEVELOPMENT OF SUPERCONDUCTING LENSES FOR A 500-KV ELECTRON MICROSCOPE COLUMN
    WORSHAM, RE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1968, 13 (12): : 1740 - &
  • [26] VERY HIGH-VOLTAGE (500 KV) ELECTRON-BEAM LITHOGRAPHY FOR THICK RESISTS AND HIGH-RESOLUTION
    JONES, GAC
    BLYTHE, S
    AHMED, H
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 1987, 5 (01): : 120 - 123
  • [27] Voltage distribution analysis of 500-kV DC transmission-line voltage divider under impulse voltages: Results and discussions
    Gu, SQ
    Han, SJ
    He, JL
    Chen, SM
    Xu, GZ
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 584 - 590
  • [28] High voltage dc gun for high intensity polarized electron source
    Wang, Erdong
    Rahman, Omer
    Skaritka, John
    Liu, Wei
    Biswas, Jyoti
    Degen, Christopher
    Inacker, Patrick
    Lambiase, Robert
    Paniccia, Matthew
    PHYSICAL REVIEW ACCELERATORS AND BEAMS, 2022, 22 (03)
  • [29] High voltage threshold for stable operation in a dc electron gun
    Yamamoto, Masahiro
    Nishimori, Nobuyuki
    APPLIED PHYSICS LETTERS, 2016, 109 (01)
  • [30] Effect of Line Voltage on Lightning Attachment to 220-kV and 500-kV Lines
    Podporkin, Georgy
    2017 INTERNATIONAL SYMPOSIUM ON LIGHTNING PROTECTION (XIV SIPDA), 2017, : 7 - 13