Severe Aortic Regurgitation of Early Degenerated Mitroflow Bioprosthesis: From Echocardiographic Diagnosis to Treatment with Valve-in-Valve Transcatheter Aortic Valve Implantation

被引:0
作者
Pernigo, Matteo [1 ]
Triggiani, Marco [1 ]
Adamo, Marianna [2 ]
Pasini, Gian Franco [1 ]
机构
[1] ASST Garda, La Mem Hosp, Dept Cardiol, Brescia, Italy
[2] Spedali Civili Hosp, Cath Lab Unit, Dept Cardiol, Brescia, Italy
关键词
Mitroflow aortic valve; three-dimensional transesophageal echocardiography; Valve-in-Valve transcatheter aortic valve implantation; DETERIORATION; DURABILITY;
D O I
10.4103/jcecho.jcecho_129_20
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Valve-in-Valve transcatheter aortic valve implantation (ViV TAVI) is emerging as an effective therapeutic option for bioprosthetic valve failure. Recently, concern has been raised for early valve deterioration of Mitroflow (Sorin) aortic bioprosthesis, with the development of prevalent stenosis. We report cases of pure severe aortic regurgitation (AR) due to early and mid-term prosthesis degeneration. From June 2018 to October 2019, three patients were treated in our division for the new appearance of severe intraprosthetic regurgitation. Patient 1 (man, 85-year-old) and patient 3 (woman, 83-year-old) had a Mitroflow n. 25 and n. 21 implanted, respectively, in 2012 and 2013 for severe aortic stenosis. Patient 2, a 67-year-old woman with Marfan syndrome underwent a Mitroflow n. 25 implant in 2008 for severe AR and presented chronic type-B aortic dissection. Patient 1 was diagnosed with severe AR in the ambulatory setting, while the other patients presented acute heart failure, requiring inotrope support and high doses intravenous diuretics, and in case 3, temporary extracorporeal ultrafiltration. All patients appeared at high surgical risk and were successfully treated with ViV TAVI, through the right axillary artery in patient 2, and through the femoral artery in patients 1 and 3. Results were good at short- and mid-term follow-up. In conclusion, early and midterm bioprosthesis degeneration with the development of severe AR is a possible complication of the Mitroflow aortic valve. ViV TAVI has been confirmed as a safe and effective therapeutic option in our cases.
引用
收藏
页码:51 / 54
页数:4
相关论文
共 8 条
[1]   The Mitroflow aortic valve: A past, present, and future illuminated [J].
Balsam, Leora B. ;
DeAnda, Abe, Jr. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (01) :40-42
[2]   Transcatheter Aortic Valve Implantation in Failed Bioprosthetic Surgical Valves [J].
Dvir, Danny ;
Webb, John G. ;
Bleiziffer, Sabine ;
Pasic, Miralem ;
Waksman, Ron ;
Kodali, Susheel ;
Barbanti, Marco ;
Latib, Azeem ;
Schaefer, Ulrich ;
Rodes-Cabau, Josep ;
Treede, Hendrik ;
Piazza, Nicolo ;
Hildick-Smith, David ;
Himbert, Dominique ;
Walther, Thomas ;
Hengstenberg, Christian ;
Nissen, Henrik ;
Bekeredjian, Raffi ;
Presbitero, Patrizia ;
Ferrari, Enrico ;
Segev, Amit ;
de Weger, Arend ;
Windecker, Stephan ;
Moat, Neil E. ;
Napodano, Massimo ;
Wilbring, Manuel ;
Cerillo, Alfredo G. ;
Brecker, Stephen ;
Tchetche, Didier ;
Lefevre, Thierry ;
De Marco, Federico ;
Fiorina, Claudia ;
Petronio, Anna Sonia ;
Teles, Rui C. ;
Testa, Luca ;
Laborde, Jean-Claude ;
Leon, Martin B. ;
Kornowski, Ran .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2014, 312 (02) :162-170
[3]   Structural valve deterioration in the Mitroflow biological heart valve prosthesis [J].
Issa, Issa Farah ;
Poulsen, Steen Hvitfeldt ;
Waziri, Farhad ;
Pedersen, Christian Torp ;
Nielsen, Per Hostrup ;
Riber, Lars ;
Dahl, Jordi S. ;
Sogaard, Peter ;
Norgaard, Martin Agge ;
Moller, Jacob Eifer .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2018, 53 (01) :136-142
[4]   Long-term results of the Mitroflow aortic pericardial bioprosthesis in over 800 patients: limited durability and mechanisms of dysfunction [J].
Ius, Fabio ;
Schulz, Julia ;
Roumieh, Mazen ;
Fleissner, Felix ;
Ismail, Issam ;
Tudorache, Igor ;
Warnecke, Gregor ;
Martens, Andreas ;
Shrestha, Malakh ;
Boethig, Dietmar ;
Haverich, Axel ;
Cebotari, Serghei .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2017, 52 (02) :264-271
[5]   Pathologic Evaluation of 28 Mitroflow Pericardial Valves: A 12-Year Experience [J].
Luk, Adriana ;
Cusimano, Robert J. ;
Butany, Jagdish .
ANNALS OF THORACIC SURGERY, 2015, 99 (01) :48-54
[6]   Long-Term Outcomes and Durability of the Mitroflow Aortic Bioprosthesis [J].
Mosquera, Victor X. ;
Bouzas-Mosquera, Alberto ;
Velasco-Garcia, Carlos ;
Muniz, Javier ;
Estevez-Cid, Francisco ;
Portela-Torron, Francisco ;
Herrera-Norena, Jose M. ;
Cuenca-Castillo, Jose J. .
JOURNAL OF CARDIAC SURGERY, 2016, 31 (05) :264-273
[7]   Early Structural Valve Deterioration of Mitroflow Aortic Bioprosthesis Mode, Incidence, and Impact on Outcome in a Large Cohort of Patients [J].
Senage, Thomas ;
Le Tourneau, Thierry ;
Foucher, Yohann ;
Pattier, Sabine ;
Cueff, Caroline ;
Michel, Magali ;
Serfaty, Jean-Michel ;
Mugniot, Antoine ;
Perigaud, Christian ;
Carton, Hubert Francois ;
Al Habash, Ousama ;
Baron, Olivier ;
Roussel, Jean Christian .
CIRCULATION, 2014, 130 (23) :2012-2020
[8]  
Yankah CA, 2005, J HEART VALVE DIS, V14, P172