Application of activated charcoal radon collectors in high humidity environments

被引:10
作者
Iimoto, T
Tokonami, S
Morishita, Y
Kosako, T
机构
[1] Univ Tokyo, Nucl Sci & Technol Res Ctr, Bunkyo Ku, Tokyo 1130032, Japan
[2] Natl Inst Radiol Sci, Res Ctr Radiat Safety, Inage Ku, Chiba, Chiba 2638555, Japan
关键词
radon (Rn-222); activated charcoal; ST-100 (Pico-Rad); calibration; sensitivity; humidity;
D O I
10.1016/j.jenvrad.2004.03.037
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Most commercially based activated charcoal radon collectors were designed for use in indoor environments. However, at present, they are often used for research in radon surveys in unique environments, such as in the bathrooms, underground areas, mines, caves and tunnels. In these environments, the relative humidity would be around 100%, and a change in the sensitivity of cpm(Bq m(-3))(-1)(radon) would occur. For this study, the reduction in the sensitivity of activated charcoal radon collector due to environmental humidity was investigated, and the data correction was discussed. Here, ST-100 (Pico-Rad) was selected as an example of a familiar activated charcoal radon collector. According to our performance test, the humidity of 90% (20degreesC) resulted in a 15% reduction of the sensitivity for 24 h collection. The ST-100 user should discuss the necessity of data correction by comparing the change of sensitivity with other levels of estimation errors. (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:69 / 76
页数:8
相关论文
共 10 条
[1]  
Brunauer S., 1943, The absorption of the gases and vapors. I. Physical adsorption
[2]   THEORY AND PRACTICE OF RADON MONITORING WITH CHARCOAL ADSORPTION [J].
COHEN, BL ;
COHEN, ES .
HEALTH PHYSICS, 1983, 45 (02) :501-508
[3]   AN IMPROVED PASSIVE ACTIVATED-C COLLECTOR FOR MEASURING ENVIRONMENTAL RN-222 IN INDOOR AIR [J].
GEORGE, AC ;
WEBER, T .
HEALTH PHYSICS, 1990, 58 (05) :583-589
[4]  
KOGA T, 1994, MEASUREMENT RADON AI, V29, P7
[5]   Indoor 222Rn measurements using an activated charcoal detector [J].
Murase, Y ;
Homma, Y ;
Murakami, I ;
Handa, K ;
Horiuchi, K .
APPLIED RADIATION AND ISOTOPES, 1999, 50 (03) :561-565
[6]  
PENSKO J, 1983, ACTIVATED CARBON BED, P24
[7]  
PRICHARD HM, 1982, ANAL CHEM, V55, P155
[8]  
SCARPITTA SC, 1990, HEALTH PHYS, V59, P937
[9]   AN ACTIVATED CHARCOAL-BASED, LIQUID SCINTILLATION-ANALYZED AIRBORNE RN DETECTOR [J].
SCHROEDER, MC ;
VANAGS, U ;
HESS, CT .
HEALTH PHYSICS, 1989, 57 (01) :43-49