Improved precision and accuracy for high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometric exact mass measurement of small molecules from the simultaneous and controlled introduction of internal calibrants via a second electrospray nebuliser

被引:8
|
作者
Herniman, JM [1 ]
Bristow, TWT
O'Connor, G
Jarvis, J
Langley, GJ
机构
[1] Univ Southampton, Sch Chem, Southampton SO17 1BJ, Hants, England
[2] LGC Ltd, Teddington TW11 0LY, Middx, England
[3] Bruker Dalton Ltd, Coventry CV4 9GH, W Midlands, England
关键词
D O I
10.1002/rcm.1729
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The use of a second electrospray nebuliser has proved to be highly successful for exact mass measurement during high-performance liquid chromatography/Fourier transform ion cyclotron resonance mass spectrometry (HPLC/FTICRMS). Much improved accuracy and precision of mass measurement were afforded by the introduction of the internal calibration solution, thus overcoming space charge issues due to the lack of control over relative ion abundances of the species eluting from the HPLC column. Further, issues of suppression of ionisation, observed when using a T-piece method, are addressed and this simple system has significant benefits over other more elaborate approaches providing data that compares very favourably with these other approaches. The technique is robust, flexible and transferable and can be used in conjunction with HPLC, infusion or flow injection analysis (FIA) to provide constant internal calibration signals to allow routine, accurate and precise mass measurements to be recorded. Copyright (C) 2004 John Wiley Sons, Ltd.
引用
收藏
页码:3035 / 3040
页数:6
相关论文
共 25 条
  • [1] Packed capillary reversed-phase liquid chromatography with high-performance electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for proteomics
    Shen, YF
    Zhao, R
    Belov, ME
    Conrads, TP
    Anderson, GA
    Tang, KQ
    Pasa-Tolic, L
    Veenstra, TD
    Lipton, MS
    Udseth, HR
    Smith, RD
    ANALYTICAL CHEMISTRY, 2001, 73 (08) : 1766 - 1775
  • [2] Proteome analysis of Escherichia coli using high-performance liquid chromatography and Fourier transform ion cyclotron resonance mass spectrometry
    Ihling, C
    Sinz, A
    PROTEOMICS, 2005, 5 (08) : 2029 - 2042
  • [3] Metabolic profile of salidroside in rats using high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry
    Fei Han
    Yan-ting Li
    Xin-juan Mao
    Xiao-shu Zhang
    Jiao Guan
    Ai-hua Song
    Ran Yin
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1975 - 1981
  • [4] Quality control of Semen Hoveniae by high-performance liquid chromatography coupled to Fourier transform-ion cyclotron resonance mass spectrometry
    Zhang, Qingyu
    Xu, Ke
    Zhang, Yu
    Han, Jing
    Sui, Wenwen
    Zhang, Haotian
    Yu, Maomao
    Tong, Yichen
    Wang, Sijie
    Han, Fei
    JOURNAL OF SEPARATION SCIENCE, 2021, 44 (18) : 3366 - 3375
  • [5] Metabolic profile of salidroside in rats using high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry
    Han, Fei
    Li, Yan-ting
    Mao, Xin-juan
    Zhang, Xiao-shu
    Guan, Jiao
    Song, Ai-hua
    Yin, Ran
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (07) : 1975 - 1981
  • [6] Structural analysis of monoterpene glycosides extracted from Paeonia lactiflora Pall. using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry and high-performance liquid chromatography/electrospray ionization tandem mass spectrometry
    Dong, Hongjuan
    Liu, Zhiqiang
    Song, Fengrui
    Yu, Zhan
    Li, Huilin
    Liu, Shuying
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (19) : 3193 - 3199
  • [7] Erratum to: Metabolic profile of salidroside in rats using high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry
    Fei Han
    Yan-ting Li
    Xin-juan Mao
    Xiao-shu Zhang
    Jiao Guan
    Ai-hua Song
    Ran Yin
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1983 - 1983
  • [8] Identification of active compounds and their metabolites by high-performance liquid chromatography/electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry from Xiao-xu-ming decoction (XXMD)
    Wang, Yilin
    Ding, Chunguang
    Du, Kehe
    Xiao, Yao
    Wu, Caisheng
    Zhang, Jinlan
    Qin, Hailin
    Du, Guanhua
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (17) : 2724 - 2732
  • [9] Identification of chemical components in Baidianling Capsule based on gas chromatography-mass spectrometry and high-performance liquid chromatography combined with Fourier transform ion cyclotron resonance mass spectrometry
    Wu, Wenying
    Chen, Yu
    Wang, Binjie
    Sun, Xiaoyang
    Guo, Ping
    Chen, Xiaohui
    JOURNAL OF SEPARATION SCIENCE, 2017, 40 (16) : 3188 - 3195
  • [10] Qualitative and quantitative analysis of Alpiniae Oxyphyllae Fructus by high-performance liquid chromatography coupled to Fourier transform-ion cyclotron resonance mass spectrometry
    Zhang, Yu
    Dong, Lei
    Zhang, Qingyu
    Han, Jing
    Sui, Wenwen
    Wei, Ziyun
    Zhang, Zan
    Tong, Yichen
    Wang, Sijie
    Han, Fei
    JOURNAL OF SEPARATION SCIENCE, 2022, 45 (06) : 1185 - 1194