In Vitro Ultrasonographic Measurement of Jawbone to Predict Bone Quality

被引:0
作者
Chan, Carrie Ka Lei [1 ]
Chai, John Y. [2 ]
Wah, Chow Tak [3 ]
机构
[1] Univ Hong Kong, Fac Dent, Prince Philip Dent Hosp, Hong Kong, Hong Kong, Peoples R China
[2] Northwestern Univ, Evanston, IL USA
[3] Univ Hong Kong, Fac Dent, Hong Kong, Hong Kong, Peoples R China
关键词
bone quality; Hounsfield units; quantitative ultrasound; speed of sound; POPULATION-BASED SAMPLE; QUANTITATIVE ULTRASOUND; MINERAL DENSITY; CORTICAL BONE; VERTEBRAL FRACTURES; VIVO; ARCHITECTURE; THICKNESS; CALCANEUS; VELOCITY;
D O I
10.11607/jomi.3823
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this in vitro study was to determine whether there is a correlation between the speed of sound (SOS), as measured by quantitative ultrasound (QUS), and bone quality, as expressed in Hounsfield units (HU) measured by spiral computed tomography in the mandible. Materials and Methods: Dry human mandibles (n = 23) with 69 regions of interest (ROls) were selected for QUS and computed tomographic measurements of SOS and HU, respectively. The three ROls defined in each mandible were the right canine, left canine, and central incisor regions. A time-of-flight approach was used to establish the SOS through bone. The mean HU value derived from scanned computed tomographic images of each ROI was evaluated for correlation with SOS. Results: The Spearman rho test revealed a modest but significant correlation between SOS and HU (R-2 quadratic = 0.339, P < .01). Conclusion: In this in vitro study conducted in dry human mandibles, a statistically significant correlation was identified between QUS and HU.
引用
收藏
页码:1042 / 1048
页数:7
相关论文
共 37 条
  • [1] Experimental evaluation of bone quality measuring speed of sound in cadaver mandibles
    Al Haffar, Iyad
    Padilla, Frederic
    Nefussi, Raphael
    Kolta, Sami
    Foucart, Jean-Michel
    Laugier, Pascal
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2006, 102 (06): : 782 - 791
  • [2] [Anonymous], 1999, DOPPLER ULTRASOUND P
  • [3] A device for in vivo measurements of quantitative ultrasound variables at the human proximal femur
    Barkmann, Reinhard
    Laugier, Pascal
    Moser, Urs
    Dencks, Stefanie
    Klausner, Michael
    Padilla, Frederic
    Haiat, Guilleaume
    Glueer, Claus-C.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (06) : 1197 - 1204
  • [4] Comparison of radiation dose for implant imaging using conventional spiral tomography, computed tomography, and cone-beam computed tomography
    Chau, Anson C. M.
    Fung, Karl
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (04): : 559 - 565
  • [5] Does quantitative ultrasound of bone reflect more bone mineral density than bone microarchitecture?
    Cortet, B
    Boutry, N
    Dubois, P
    Legroux-Gérot, I
    Cotten, A
    Marchandise, X
    [J]. CALCIFIED TISSUE INTERNATIONAL, 2004, 74 (01) : 60 - 67
  • [6] Influence of bone tissue density and elasticity on ultrasound propagation:: An in vitro study
    De Terlizzi, F
    Battista, S
    Cavani, F
    Canè, V
    Cadossi, R
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2000, 15 (12) : 2458 - 2466
  • [7] Longitudinal changes in mandibular bone mineral density compared with hip bone mineral density and quantitative ultrasound at calcaneus and hand phalanges
    Drozdzowska, B
    Pluskiewicz, W
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (897) : 743 - 747
  • [8] A new quality of bone ultrasound research
    Glueer, Claus-C.
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (07) : 1524 - 1528
  • [9] Association of five quantitative ultrasound devices and bone densitometry with osteoporotic vertebral fractures in a population-based sample:: the OPUS study
    Glüer, CC
    Eastell, R
    Reid, DM
    Felsenberg, D
    Roux, C
    Barkmann, R
    Timm, W
    Blenk, T
    Armbrecht, G
    Stewart, A
    Clowes, J
    Thomasius, FE
    Kolta, S
    [J]. JOURNAL OF BONE AND MINERAL RESEARCH, 2004, 19 (05) : 782 - 793
  • [10] Phalangeal US velocity discriminates between normal and vertebrally fractured subjects
    Guglielmi, G
    Cammisa, M
    De Serio, A
    Scillitani, A
    Chiodini, I
    Carnevale, V
    Fusilli, S
    [J]. EUROPEAN RADIOLOGY, 1999, 9 (08) : 1632 - 1637