Application of Nanosized LiFePO4 Modified Electrode to Electrochemical Sensor and Biosensor

被引:3
作者
Wen, Zuorui [1 ]
Niu, Xueliang [1 ]
Li, Xiaoyan [1 ]
Zhao, Wenshu [1 ]
Li, Xiaobao [1 ]
Ma, Dongxue [1 ]
Deng, Ying [1 ]
Sun, Xiaohuan [1 ]
Sun, Wei [1 ]
机构
[1] Hainan Normal Univ, Coll Chem & Chemicalengn, Minist Educ, Key Lab Trop Med Plant Chem, Haikou 571158, Hainan, Peoples R China
基金
中国国家自然科学基金;
关键词
LiFePO4; nanoparticle; hemoglobin; rutin; electrochemistry; electrocatalysis; carbon ionic liquid electrode; LITHIUM IRON PHOSPHATE; GLASSY-CARBON ELECTRODE; IONIC LIQUID; CATHODE MATERIALS; PASTE ELECTRODE; RUTIN; ELECTROCATALYSIS; PERFORMANCE; HEMOGLOBIN; COMPOSITE;
D O I
10.2174/1573411013666170824150715
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background: The development of nanomaterials modified electrode can provide more opportunities for the enhancement of the analytical performance in constructing electrochemical sensor and biosensor. LiFePO4 (LFP) is a promising candidate to develop new modified electrodes owing to its advantages such as cheap cost, environmental compatibility, high safety, non-toxicity, large theoretical capacity, long cycle life and abundant earth materials. Objective: The aim of this paper was to construct nanosized LFP modified electrodes, which could be applied as working electrode for rutin analysis and as an electrochemical biosensor for direct electro-chemistry of Hemoglobin (Hb). Method: Nanosized LFP was characterized by scanning electron microscopy. The LFP modified electrodes with Carbon Ionic Liquid Electrode (CILE) as substrate electrode were fabricated by dropping method with chitosan (CTS) as film. Cyclic voltammetry and electrochemical impedance spectroscopy were carried out to examine the electrochemical performance of the modified electrodes. Differential pulse voltammetry was used to establish determination methods. Results: Two new LFP-based modified electrodes (CTS/LFP/CILE and CTS/Hb-LFP/CILE) were fabricated. The electrochemical behaviors of rutin on CTS/LFP/CILE were achieved with a pair of enhanced redox peaks. The linear range for rutin analysis was from 4.0 x 10(-8) to 1.0 x 10(-4) mol L-1 with a detection limit of 8.0 x 10(-9) mol L-1. The direct electrochemistry of Hb in CTS/Hb-LFP/CILE was realized with a pair of obvious redox peaks. The electrocatalytic activity of CTS/Hb-LFP/CILE toward trichloroacetic acid and H2O2 reduction were investigated, and the detection limits of 0.068 mmol L-1 for TCA and 0.07 mu mol L-1 for H2O2 were obtained. Conclusion: Two kinds of LFP modified electrodes were successfully constructed with improved electrochemical performances. Electrochemistry of rutin and Hb were realized on LFP based electrodes with enhanced responses, and the application of LFP nanoparticle in electrochemical sensor and biosensors was extended.
引用
收藏
页码:452 / 457
页数:6
相关论文
共 37 条
[1]  
Bard A.J, 2002, Student Solutions Manual to accompany Electrochemical Methods: Fundamentals and Applicaitons, V2e
[2]   Protein adsorption onto nanomaterials for the development of biosensors and analytical devices: A review [J].
Bhakta, Samir A. ;
Evans, Elizabeth ;
Benavidez, Tomas E. ;
Garcia, Carlos D. .
ANALYTICA CHIMICA ACTA, 2015, 872 :7-25
[3]   Determination of puerarin, daidzein and rutin in Pueraria lobata (Wild.) Ohwi by capillary electrophoresis with electrochemical detection [J].
Chen, G ;
Zhang, JX ;
Ye, JN .
JOURNAL OF CHROMATOGRAPHY A, 2001, 923 (1-2) :255-262
[4]   Judicious design of lithium iron phosphate electrodes using poly(3,4-ethylenedioxythiophene) for high performance batteries [J].
Cintora-Juarez, Daniel ;
Perez-Vicente, Carlos ;
Kazim, Samrana ;
Ahmad, Shahzada ;
Luis Tirado, Jose .
JOURNAL OF MATERIALS CHEMISTRY A, 2015, 3 (27) :14254-14262
[5]   Environmentally Friendly Synthesis of LiFePO4 Using Fe-P Waste Slag and Greenhouse Gas CO2 [J].
Cui, Qian ;
Luo, Chunhui ;
Li, Gen ;
Wang, Guixin ;
Yan, Kangping .
INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (26) :7069-7075
[6]   Electrical Energy Storage for the Grid: A Battery of Choices [J].
Dunn, Bruce ;
Kamath, Haresh ;
Tarascon, Jean-Marie .
SCIENCE, 2011, 334 (6058) :928-935
[7]   Electrochemical performance of microdisc-shaped carbon-coated lithium iron phosphate with preferentially exposed (010) planes in lithium sulfate aqueous solution [J].
Fan, Xuliang ;
Luo, Jingjing ;
Shao, Chen ;
Zhou, Xiaoshun ;
Niu, Zhenjiang .
ELECTROCHIMICA ACTA, 2015, 158 :342-347
[8]   Rutin determination in pharmaceutical formulations using a carbon paste electrode modified with poly(vinylpyrrolidone) [J].
Franzoi, Ana Cristina ;
Spinelli, Almir ;
Vieira, Iolanda Cruz .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) :973-977
[9]   Application of a Cu-chitosan/multiwalled carbon nanotube film-modified electrode for the sensitive determination of rutin [J].
Gholivand, Mohammad Bagher ;
Mohammadi-Behzad, Leila ;
Hosseinkhani, Hossein .
ANALYTICAL BIOCHEMISTRY, 2016, 493 :35-43
[10]   Synthesis of 3D-hiearchical LiMPO4 (M = Fe, Mn) microstructures as cathode materials for lithium-ion batteries [J].
Gu, Yuanxiang ;
Liu, Weiming ;
Wang, Lei ;
Li, Guicun ;
Yang, Yu .
CRYSTENGCOMM, 2013, 15 (24) :4865-4870