Flow injection analysis in a microfluidic format

被引:79
作者
Leach, AM [1 ]
Wheeler, AR [1 ]
Zare, RN [1 ]
机构
[1] Stanford Univ, Dept Chem, Stanford, CA 94305 USA
关键词
D O I
10.1021/ac026112l
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A microfluidic flow injection analysis system has been designed and evaluated. The system incorporates within a single two-layer poly(dimediylsiloxane) monolith multiple pneumatically driven peristaltic pumps, an injection loop, a mixing column, and a transparent window for fluorescence detection. Central to this device is an injection system that mimics the operation of a standard sixport, two-way valve used in conventional liquid chromatography and flow injection experiments. Analyte and carrier solutions continuously flow through this injection system allowing for measurements and sample changes to be performed rapidly and simultaneously. Injection volumes of 1.25 nL generated peak area reproducibility of better than 3% relative standard deviation. The flow injection device was evaluated with fluorescent dyes and demonstrated a detection limit of 400 zmol for fluorescein. A rudimentary sample selection system allowed calibration curves to be rapidly produced, often in less than 10 min. The hydrolysis of fluorescein diphosphate by alkaline phosphatase demonstrates that chemical assays can be carried out with this device in a manner characterized by short analysis times and low sample consumption.
引用
收藏
页码:967 / 972
页数:6
相关论文
共 28 条
[1]   Micro total analysis systems. 2. Analytical standard operations and applications [J].
Auroux, PA ;
Iossifidis, D ;
Reyes, DR ;
Manz, A .
ANALYTICAL CHEMISTRY, 2002, 74 (12) :2637-2652
[2]  
Barrer R.M., 1965, J POLYM SCI POL SYM, P111
[3]   A Microfabricated Rotary Pump [J].
Chou, Hou-Pu ;
Unger, Marc A. ;
Quake, Stephen R. .
BIOMEDICAL MICRODEVICES, 2001, 3 (04) :323-330
[4]  
Copeland R. A., 2000, ENZYMES
[5]   Studies on single alkaline phosphatase molecules: Reaction rate and activation energy of a reaction catalyzed by a single molecule and the effect of thermal denaturation - The death of an enzyme [J].
Craig, DB ;
Arriaga, EA ;
Wong, JCY ;
Lu, H ;
Dovichi, NJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1996, 118 (22) :5245-5253
[6]   Diffusion coefficient measurements in microfluidic devices [J].
Culbertson, CT ;
Jacobson, SC ;
Ramsey, JM .
TALANTA, 2002, 56 (02) :365-373
[7]  
EMNEUS J, 2001, P MICR TOT AN SYST 2, P432
[9]   An integrated microfabricated cell sorter [J].
Fu, AY ;
Chou, HP ;
Spence, C ;
Arnold, FH ;
Quake, SR .
ANALYTICAL CHEMISTRY, 2002, 74 (11) :2451-2457
[10]   Microchip device for performing enzyme assays [J].
Hadd, AG ;
Raymond, DE ;
Halliwell, JW ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1997, 69 (17) :3407-3412