Geometrical dimensions of the lower lumbar vertebrae analysis of data from digitised CT images

被引:148
作者
Zhou, SH [1 ]
McCarthy, ID [1 ]
McGregor, AH [1 ]
Coombs, RRH [1 ]
Hughes, SPF [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Charing Cross Hosp, Dept Orthopaed & Trauma Surg, London W6 8RF, England
关键词
lumbar vertebrae; anatomical dimensions; spine;
D O I
10.1007/s005860000140
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The precise dimensions of the lumbar vertebrae and discs are critical for the production of appropriate spinal implants. Unfortunately, existing databases of vertebral and intervertebral dimensions are limited either in accuracy, study population or parameters recorded. The objective of this study is to provide a large and accurate database of lumbar spinal characteristics from 126 digitised computed tomographic (CT) images, reviewed using the Picture Archiving Communication System (PACS) coupled with its internal measuring instrumentation. These CT images were obtained from patients with low back pain attending the spinal clinic at the Hammersmith Hospitals NHS Trust. Measurements of various aspects of vertebral dimensions and geometry were recorded, including vertebral and intervertebral disc height. The results from this study indicated that the depth and width of the vertebral endplate increased from the third to the fifth lumbar vertebra. Anterior vertebral height remained the same from the third to the fifth vertebra, but the posterior vertebral height decreased. Mean disc height in the lower lumbar segments was 11.6 +/- 1.8 mm for the L3/4 disc, 11.3 +/- 2.1 mm for the L4/5, and 10.7 +/- 2.1 mm for the L5/S1 level. The average circumference of the lower endplate of the fourth lumbar vertebra was 141 mm and the average surface area was 1492 mm(2). An increasing pedicle width from a mean of 9.6 +/- 2.2 mm at L3 through to 16.2 +/- 2.8 mm at L5 was noted. A comprehensive database of vertebral and intervertebral dimensions was generated from 378 lumbar vertebrae from 126 patients measured with a precise digital technique. These results are invaluable in establishing an anthropometric model of the human lumbar spine, and provide useful data for anatomical research. In addition this is important information for the scientific planning of spinal surgery and for the design of spinal implants.
引用
收藏
页码:242 / 248
页数:7
相关论文
共 36 条
[1]   A MORPHOMETRIC STUDY OF HUMAN LUMBAR AND SELECTED THORACIC VERTEBRAE [J].
BERRY, JL ;
MORAN, JM ;
BERG, WS ;
STEFFEE, AD .
SPINE, 1987, 12 (04) :362-367
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   A CARBON-FIBER IMPLANT TO AID INTERBODY LUMBAR FUSION - 2-YEAR CLINICAL-RESULTS IN THE 1ST 26 PATIENTS [J].
BRANTIGAN, JW ;
STEFFEE, AD .
SPINE, 1993, 18 (14) :2106-2117
[4]  
Calandruccio R A, 1964, Clin Orthop Relat Res, V35, P63
[5]   INCREASING NEUROFORAMINAL VOLUME BY ANTERIOR INTERBODY DISTRACTION IN DEGENERATIVE LUMBAR SPINE [J].
CHEN, DY ;
FAY, LA ;
LOK, J ;
YUAN, P ;
EDWARDS, WT ;
YUAN, HA .
SPINE, 1995, 20 (01) :74-79
[6]   MECHANICS OF INTERBODY SPINAL-FUSION - ANALYSIS OF CRITICAL BONE-GRAFT AREA [J].
CLOSKEY, RF ;
PARSONS, JR ;
LEE, CK ;
BLACKSIN, MF ;
ZIMMERMAN, MC .
SPINE, 1993, 18 (08) :1011-1015
[7]   MORPHOMETRY AND PATHOLOGICAL ANATOMY OF LUMBAR SPINE IN SOUTH-AFRICAN NEGROES AND CAUCASOIDS WITH SPECIFIC REFERENCE TO SPINAL STENOSIS [J].
EISENSTEIN, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1977, 59 (02) :173-180
[8]   LUMBAR VERTEBRAL CANAL MORPHOMETRY FOR COMPUTERIZED-TOMOGRAPHY IN SPINAL STENOSIS [J].
EISENSTEIN, S .
SPINE, 1983, 8 (02) :187-191
[9]  
Elsberg C. A., 1934, B NEUROL I NY, V3, P359
[10]  
ENKER P, 1994, CLIN ORTHOP RELAT R, V300, P90