Performance improvement of a naturally ventilated building integrated photovoltaic system using twisted baffle inserts

被引:14
作者
Benzarti, Salma [1 ]
Chaabane, Monia [1 ]
Mhiri, Hatem [1 ]
Bournot, Philippe [2 ]
机构
[1] Univ Monastir, Dept Energy, Lab Therm & Thermodynam Ind Proc, Monastir, Tunisia
[2] Aix Marseille Univ, CNRS, IUSTI, Marseille, France
来源
JOURNAL OF BUILDING ENGINEERING | 2022年 / 53卷
关键词
BIPV; Natural ventilation; CFD; Twisted baffles; Electrical efficiency; ENERGY PERFORMANCE; THERMAL-ANALYSIS; SOLAR COLLECTOR; AIR COLLECTOR; HEAT-TRANSFER; BIPV MODULES; DESIGN; ENHANCEMENT; EFFICIENCY; FLOW;
D O I
10.1016/j.jobe.2022.104553
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Building integrated photovoltaic (BIPV) systems constitute a key concept for the realization of sustainable buildings. However, these systems have limited efficiency and durability due to their insufficient cooling capabilities. To overcome this drawback, it is necessary to maintain the operating temperature as low as possible. This study investigates the effectiveness of a passive low-cost strategy to improve the photovoltaic module (PV) performance of naturally ventilated BIPV systems by decreasing the module operating temperature. This strategy consists of inserting twisted baffles on the rear side of a PV module to enhance its cooling performance. A numerical investigation was performed using Computational Fluid Dynamics (CFD) simulations in order to explore the module surface temperature and its electrical efficiency. The effects of solar irradiance, the number and position of twisted baffles, and twist ratio have been investigated. The results revealed that the average temperature of the PV surface decreases with the increase of the number of twisted baffles (N), which leads to an improvement in the electrical efficiency. Indeed, the optimum performance enhancement is attributed to N = 15, and the corresponding PV temperature was decreased from 312.66 K to 310.15 K and from 348.42 K to 342.64 K for a solar irradiance variation from 200 to 1000 W.m(-2), resulting in an improvement of 1.21-3.36% in electrical efficiency compared to the case without inserts. Concerning the effect of the twist ratio, it is shown that the optimum electrical efficiency improvement is reached for the lowest twist ratio, which is in the range of 1.7-6.1% for solar irradiance range from 200 to 1000 W.m(-2).
引用
收藏
页数:18
相关论文
共 66 条
[11]   Optimum depth for PV cooling ducts [J].
Brinkworth, B. J. .
SOLAR ENERGY, 2006, 80 (09) :1131-1134
[12]   Estimation of flow and heat transfer for the design of PV cooling ducts [J].
Brinkworth, BJ .
SOLAR ENERGY, 2000, 69 (05) :413-420
[13]   Thermal regulation of photovoltaic cladding [J].
Brinkworth, BJ ;
Cross, BM ;
Marshall, RH ;
Yang, HX .
SOLAR ENERGY, 1997, 61 (03) :169-178
[14]  
Chiu M-S, 2015, J APPL SCI, V15, P613, DOI DOI 10.3923/jas.2015.613.618
[15]   A review on photovoltaic/thermal hybrid solar technology [J].
Chow, T. T. .
APPLIED ENERGY, 2010, 87 (02) :365-379
[16]   An investigation on energy performance assessment of a photovoltaic solar wall under buoyancy-induced and fan-assisted ventilation system [J].
Dehra, Himanshu .
APPLIED ENERGY, 2017, 191 :55-74
[17]   Photovoltaic-thermal (PV/T) technology: a comprehensive review on applications and its advancement [J].
Diwania, Sourav ;
Agrawal, Sanjay ;
Siddiqui, Anwar S. ;
Singh, Sonveer .
INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENTAL ENGINEERING, 2020, 11 (01) :33-54
[18]   EXTENSION OF THE HOTTEL-WHILLIER MODEL TO THE ANALYSIS OF COMBINED PHOTOVOLTAIC THERMAL FLAT-PLATE COLLECTORS [J].
FLORSCHUETZ, LW .
SOLAR ENERGY, 1979, 22 (04) :361-366
[19]   Numerical determination of adequate air gaps for building-integrated photovoltaics [J].
Gan, Guohui .
SOLAR ENERGY, 2009, 83 (08) :1253-1273
[20]   Effect of air gap on the performance of building-integrated photovoltaics [J].
Gan, Guohui .
ENERGY, 2009, 34 (07) :913-921