Comparison of model predictions of image quality with results of clinical trials in chest and lumbar spine screen-film imaging

被引:10
作者
Sandborg, M [1 ]
McVey, G
Dance, DR
Carlsson, GA
机构
[1] Linkoping Univ, Fac Hlth Sci, Dept Radiat Phys, IMV, SE-58185 Linkoping, Sweden
[2] Royal Marsden NHS Trust & Inst Canc Res, London SW3 6JJ, England
关键词
D O I
10.1093/oxfordjournals.rpd.a033112
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The ability to predict image quality from known physical and technical parameters is a prerequisite for making successful dose optimisation. In this study, imaging systems have been simulated using a Monte Carlo model of the imaging systems. The model includes a voxelised human anatomy and quantifies image quality in terms of contrast and signal-to-noise ratio for 5-6 anatomical details included in the anatomy. The imaging systems used in clinical trials were simulated and the ranking of the systems by the model and radiologists compared. The model and the results of the trial for chest PA both show that using a high maximum optical density was significantly better than using a low one. The model predicts that a good system is characterised by a large dynamic range and a high contrast of the blood vessels in the retrocardiac area. The ranking by the radiologists and the model agreed for the lumbar spine AP.
引用
收藏
页码:173 / 176
页数:4
相关论文
共 11 条
  • [1] ALMEN A, UNPUB BR J RADIOL
  • [2] ALMEN A, 1998, 9801 LUGUPORP
  • [3] CARMICHAEL JHE, 1996, 16260 EUR
  • [4] The optimisation of lumbar spine AP radiography using a realistic computer model
    Dance, DR
    McVey, GH
    Sandborg, M
    Carlsson, GA
    Verdun, FR
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 207 - 210
  • [5] The influence of different technique factors on image quality for chest radiographs:: Application of the recent CEC image quality criteria
    Lanhede, B
    Tingberg, A
    Månsson, LG
    Kheddache, S
    Widell, M
    Björneld, L
    Sund, P
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 203 - 206
  • [6] IN SEARCH OF OPTIMUM CHEST RADIOGRAPHY TECHNIQUES
    LEITZ, WK
    MANSSON, LG
    HEDBERGVIKSTROM, BRK
    KHEDDACHE, S
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (784) : 314 - 321
  • [7] A COMPARISON OF PHYSICAL IMAGE QUALITY INDEXES AND OBSERVER PERFORMANCE IN THE RADIOGRAPHIC DETECTION OF NYLON BEADS
    LOO, LND
    DOI, K
    METZ, CE
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (07) : 837 - 856
  • [8] A voxel phantom based Monte Carlo computer program for optimisation of chest and lumbar spine X ray imaging systems
    Sandborg, M
    McVey, G
    Dance, DR
    Persliden, J
    Carlsson, GA
    [J]. RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 105 - 108
  • [9] SANDBORG M, 2000, RESULTS OPTIMISATION
  • [10] Efficiency of low-contrast detail detectability in fluoroscopic imaging
    Tapiovaara, MJ