Optimal configuration of adhesive ECG patches suitable for long-term monitoring of a vectorcardiogram

被引:10
作者
Kabir, Muammar M. [1 ]
Perez-Alday, Erick A. [1 ]
Thomas, Jason [1 ]
Sedaghat, Golriz [1 ]
Tereshchenko, Larisa G. [1 ]
机构
[1] Oregon Hlth & Sci Univ, Knight Cardiovasc Inst, Portland, OR 97239 USA
关键词
ECG patch; Vectorcardiogram; QRS-T angle; ATRIAL-FIBRILLATION; HEART; ELECTROCARDIOGRAPHY; RECORDINGS; MANAGEMENT; ARRHYTHMIA; PLANARITY; STROKE; SYSTEM; DEVICE;
D O I
10.1016/j.jelectrocard.2016.12.005
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of this study was to develop optimal configuration of adhesive ECG patches placement on the torso, which would provide the best agreement with the Frank orthogonal ECGs. Ten seconds of orthogonal ECG followed by 3-5 min of ECGs using patches at 5 different locations simultaneously on the torso were recorded in 50 participants at rest in sitting position. Median beat was generated for each ECG and 3 patch ECGs that best correlate with orthogonal ECGs were selected for each participant. For agreement analysis, spatial QRS-T angle, spatial QRS and T vector characteristics, spatial ventricular gradient, roundness, thickness and planarity of vectorcardiographic (VCG) loops were measured. Key VCG parameters showed high agreement in Bland-Altman analysis (spatial QRS-T angle on 3-patch ECG vs. Frank ECG bias 0.3 (95% limits of agreement [-6.23;5.71 degrees]), Lin's concordance coefficient = 0.996). In conclusion, newly developed orthogonal 3-patch ECG can be used for long-term VCG monitoring. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:342 / 348
页数:7
相关论文
共 50 条
  • [31] Optimal Long-Term Infrastructure Maintenance Planning Accounting for Traffic Dynamics
    Ng, ManWo
    Lin, Dung Ying
    Waller, S. Travis
    COMPUTER-AIDED CIVIL AND INFRASTRUCTURE ENGINEERING, 2009, 24 (07) : 459 - 469
  • [32] Adaptive monitoring: a new paradigm for long-term research and monitoring
    Lindenmayer, David B.
    Likens, Gene E.
    TRENDS IN ECOLOGY & EVOLUTION, 2009, 24 (09) : 482 - 486
  • [33] Roadmap for Long-Term Macroplastic Monitoring in Rivers
    van Emmerik, Tim
    Vriend, Paul
    Copius Peereboom, Eric
    FRONTIERS IN ENVIRONMENTAL SCIENCE, 2022, 9
  • [34] Single lead patch recording systems: The expanding role for long-term ECG recording systems
    Ben-Dov, N.
    Gladstone, D. J.
    Micieli, A.
    Crystal, E.
    Newman, D.
    JOURNAL OF ELECTROCARDIOLOGY, 2019, 55 : 54 - 58
  • [35] Optimal Sampling Intervals to Assess Long-Term Glycemic Control Using Continuous Glucose Monitoring
    Xing, Dongyuan
    Kollman, Craig
    Beck, Roy W.
    Tamborlane, William V.
    Laffel, Lori
    Buckingham, Bruce A.
    Wilson, Darrell M.
    Weinzimer, Stuart
    Fiallo-Scharer, Rosanna
    Ruedy, Katrina J.
    DIABETES TECHNOLOGY & THERAPEUTICS, 2011, 13 (03) : 351 - 358
  • [36] Differentiating Paroxysmal From Persistent Atrial Fibrillation Long-Term Electrocardiographic Monitoring Is Mightier Than the Clinician
    Mittal, Suneet
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (25) : 2849 - 2851
  • [37] ECG signal quality in intermittent long-term dry electrode recordings with controlled motion artifacts
    Joutsen, Atte
    Comert, Alper
    Kaappa, Emma
    Vanhatalo, Kirsi
    Riistama, Jarno
    Vehkaoja, Antti
    Eskola, Hannu
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [38] Wearable Smart Textiles for Long-Term Electrocardiography Monitoring-A Review
    Nigusse, Abreha Bayrau
    Mengistie, Desalegn Alemu
    Malengier, Benny
    Tseghai, Granch Berhe
    Van Langenhove, Lieva
    SENSORS, 2021, 21 (12)
  • [39] Long-term benefits of optimal asthma control in pregnancy
    Gold, Diane R.
    Litonjua, Augusto A.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2018, 141 (03) : 882 - +
  • [40] Clinical validation of a low-power and wearable ECG patch for long term full-disclosure monitoring
    Torfs, Tom
    Smeets, Christophe J. P.
    Geng, Di
    Berset, Torfinn
    Van der Auwera, Jo
    Vandervoort, Pieter
    Grieten, Lars
    JOURNAL OF ELECTROCARDIOLOGY, 2014, 47 (06) : 881 - 889