Performance Comparison of 4 Portable Oxygen Concentrators

被引:0
作者
Chatburn, Robert L. [1 ,2 ,3 ]
Williams, Thomas J. [3 ]
机构
[1] Cleveland Clin, Resp Inst, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Dept Med, Lerner Coll Med, Cleveland, OH 44106 USA
[3] Strateg Dynam, Scottsdale, AZ USA
关键词
oxygen; oxygen concentrator; nasal cannula; low flow oxygen therapy; SYSTEM;
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: Several portable oxygen concentrators (POCs) have become available in the United States. Technical trade-offs are made in designing POCs, so their performance is expected to differ. METHODS: We tested 4 POC models (Invacare XPO(2), Respironics EverGo, AirSep Free Style, and Inogen One) for oxygen delivery as a function of respiratory rate. We measured oxygen volume per pulse, pulse duration, trigger sensitivity, oxygen concentration in the gas delivered by the POC (measured with a ceramic-based oxygen sensor), and relative fraction of inspired oxygen (relative F(IO2)), measured with a setup that included an adult nasal cannula, a model flares, and a lung simulator that has a built-in oxygen sensor. We studied respiratory rates of 15, 20, 25, 30, and 35 breaths/min, at a tidal volume of 500 mL. RESULTS: The XPO(2) had the highest pulse flow, and Free Style had the lowest, which corresponded to the highest and lowest pulse volumes (40.8 mL and 18.2 mL respectively) at POC setting 2, at 15 breaths/min. The range of oxygen purity was 91.9-94.4% (P = .36). The Inogen had the shortest pulse-delivery time, and the XPO(2) had the longest (132 ms VS 281 ms. P < .001). The Free Style had the highest trigger sensitivity, and the Inogen the lowest (0.15 cm H(2)O vs 0.21 cm H(2)O, P < .001). At the maximum settings, with all 4 POCs, relative F(IO2) decreased as respiratory rate increased (relative F(IO2) range 28.6-31.4% at 15 breaths/min, 23.0-25.3% at 30 breaths/min). CONCLUSIONS: These 4 POC models have markedly different performance, which emphasizes the need to adjust the POC setting to meet the specific patient's needs at rest and with activity.
引用
收藏
页码:433 / 442
页数:10
相关论文
共 50 条
  • [31] Design and maintenance of medical oxygen concentrators in Sub-Saharan Africa: a systematic review
    Ibrahim, Nahimiya Husen
    Wallace, James
    Piaggio, Davide
    Pecchia, Leandro
    BMC HEALTH SERVICES RESEARCH, 2025, 25 (01)
  • [32] Thermal performance of parabolic concentrators under Malaysian environment: A case study
    Rafeeu, Y.
    Ab Kadir, M. Z. A.
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (06) : 3826 - 3835
  • [33] Comparison of 2 Portable Respiratory Gas Analysers
    Lepretre, P. M.
    Weissland, T.
    Paton, C.
    Jeanne, M.
    Delannaud, S.
    Ahmaidi, S.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2012, 33 (09) : 728 - 733
  • [34] A comparison of health-care costs in patients with chronic obstructive pulmonary disease using lightweight portable oxygen systems versus traditional compressed-oxygen systems
    Mapel, Douglas W.
    Robinson, Scott B.
    Lydick, Eva
    RESPIRATORY CARE, 2008, 53 (09) : 1169 - 1175
  • [35] Effect of the Anatomic Reservoir on Low-Flow Oxygen Delivery Via Nasal Cannula: Constant Flow Versus Pulse Flow With Portable Oxygen Concentrator
    Zhou, Steven
    Chatburn, Robert L.
    RESPIRATORY CARE, 2014, 59 (08) : 1199 - 1209
  • [36] A laboratory assessment of oxygen delivery from a portable chemical generator
    Murray, WB
    Bhimsan, NR
    Rout, CC
    ANAESTHESIA, 1996, 51 (12) : 1127 - 1128
  • [37] A new portable optical sensor for dual sensing of temperature and oxygen
    Chu, Cheng-Shane
    Lin, Ting-Hsun
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 202 : 508 - 515
  • [38] Thermal and concentration performance for a wide range of available offset dish solar concentrators
    Ruelas, Jose
    Sauceda, Daniel
    Vargas, Juan
    Garcia, Rafael
    APPLIED THERMAL ENGINEERING, 2018, 144 : 13 - 20
  • [39] Design and Performance of a Portable and Multichannel SPR Device
    Zhang, Xiao-ling
    Liu, Yan
    Fan, Ting
    Hu, Ning
    Yang, Zhong
    Chen, Xi
    Wang, Zhen-yu
    Yang, Jun
    SENSORS, 2017, 17 (06):
  • [40] Performance of a New Portable Wireless Sleep Monitor
    Younes, Magdy
    Soiferman, Marc
    Thompson, Wayne
    Giannouli, Eleni
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2017, 13 (02): : 245 - 258