Formulation of matrix solutions for use in matrix-assisted laser desorption ionization of biomolecules

被引:55
|
作者
Sze, ETP
Chan, TWD [1 ]
Wang, G
机构
[1] Chinese Univ Hong Kong, Dept Chem, Shatin, Peoples R China
[2] Chinese Acad Sci, Inst Chem, Beijing 100080, Peoples R China
关键词
D O I
10.1016/S1044-0305(97)00237-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We report a simple method for converting solid matrices into useful matrix solutions for matrix-assisted laser desorption/ionization (MALDI). This method is based on the dissolution of the solid matrix in a liquid support of low volatility such as glycerol. An appropriate solubilizing reagent was added to promote the dissolution of the matrix materials into the Liquid support. Selection of the solubilizing reagent is empirically related to an acid-base relationship, i.e., an acidic solid matrix requires a basic organic compound to form a stable matrix solution in the liquid support and vice versa. A tenfold increase in the solubility can be obtained for many solid matrices when appropriate solubilizing reagents are added into the glycerol support. This solubility enhancement is tentatively attributed to the ion-pair formation in a polar nonvolatile liquid support. Ln addition, the hydrophobicity of the solid matrix seems to play an important role in the efficiency of the resulting matrix solution. By using glycerol as liquid support, a hydrophilic matrix, such as 2,5-dihydroxybenzoic acid (DHB), showed a substantial "peripheral effect," in which good analyte ion signals could only be recorded at the peripheral region of the sample droplet. More hydrophobic matrices, such as alpha-cyano-4-hydroxycinnamic acid (alpha-CCA), exhibit better and more homogeneous responses at different regions of the droplets. The performance of these matrix solutions was evaluated in terms of the durability, reproducibility, sensitivity, high mass capability, and generality. A typical sample droplet can afford more than an hour of repeated sampling with excellent shot-to-shot reproducibility. A low picomole sensitivity was demonstrated using a luteinizing hormone releasing hormone (LHRH) in a Fourier transform ion cyclotron resonance mass spectrometer with a homemade external MALDI ion source. By using a commercial MALDI time-of-flight mass spectrometer, proteins with masses as high as 66,000 Da were successfully analyzed by using these matrix solutions. (C) 1998 American Society for Mass Spectrometry.
引用
收藏
页码:166 / 174
页数:9
相关论文
共 50 条
  • [1] Fast dynamics of ionization in ultraviolet matrix-assisted laser desorption ionization of biomolecules
    Moskovets, E
    Vertes, A
    JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (12): : 3301 - 3306
  • [2] Matrix-assisted laser desorption/ionization
    Kazazic, S.
    Pecur, S.
    Srzic, D.
    Kemija u industriji/Journal of Chemists and Chemical Engineers, 1999, 48 (05): : 181 - 187
  • [4] Ionization Mechanism of Matrix-Assisted Laser Desorption/Ionization
    Lu, I-Chung
    Lee, Chuping
    Lee, Yuan-Tseh
    Ni, Chi-Kung
    ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 8, 2015, 8 : 21 - 39
  • [6] Lasers for matrix-assisted laser desorption ionization
    Murray, Kermit K.
    JOURNAL OF MASS SPECTROMETRY, 2021, 56 (06):
  • [7] Matrix-assisted laser desorption/ionization of ginsenosides
    Zhou, Y
    Song, FR
    Liu, SY
    Li, XG
    ACTA CHIMICA SINICA, 1998, 56 (03) : 298 - 301
  • [8] Use of graphene as a matrix to minimize reduction in the process of matrix-assisted laser desorption/ionization
    Zhang, Sen
    Ding, Liying
    Li, Shuqi
    Kong, Xianglei
    Huang, Yi
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2013, 27 (11) : 1278 - 1282
  • [9] Derivatization of small biomolecules for optimized matrix-assisted laser desorption/ionization mass spectrometry
    Tholey, A
    Wittmann, C
    Kang, MJ
    Bungert, D
    Hollemeyer, K
    Heinzle, E
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (09): : 963 - 973
  • [10] Ionization modelling of matrix molecules in ultraviolet matrix-assisted laser desorption/ionization
    Allwood, DA
    Dyer, PE
    Dreyfus, RW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1997, 11 (05) : 499 - 503