Fabry-Perot cavity cascaded sagnac loops for temperature and strain measurements

被引:3
|
作者
Shangguan, Chunmei [1 ,2 ,3 ]
Zhang, Wen [1 ,2 ,3 ]
Hei, Wei [1 ,2 ,3 ]
Luo, Fei [1 ,2 ,3 ]
Zhu, Lianqing [1 ,2 ,3 ]
机构
[1] Beijing Informat Sci & Technol Univ, Beijing Engn Res Ctr Optoelect Informat & Instrum, Beijing, Peoples R China
[2] Minist Educ, Key Lab Modern Measurement Control Technol, Beijing, Peoples R China
[3] Beijing Informat Sci & Technol Univ, Beijing Key Lab Optoelect Test Technol, Beijing, Peoples R China
关键词
chemical etched; Fabry-Perot cavity; sagnac loops; temperature; strain;
D O I
10.1117/1.OE.57.4.047103
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The fabrication process and temperature and strain characterizations of an all-fiber sensor are presented. The sensing structure based on a Fabry-Perot cavity (FPC) and sagnac loops was proposed and experimentally demonstrated for measurements of temperature and strain. The FPC consists of a micro-piece of chemical etched multimode fiber end face, welded with another single mode fiber. Then, the sagnac loops composed of polarization maintaining fiber was connected to the FPC. The sensor was fabricated and tested for temperature and strain. Experimental results show that sensitivity of temperature and strain is 0.71 +/- 0.03 nm/degrees C and 1.30 +/- 0.01 pm/mu epsilon, respectively; the linearity are 0.9970 and 0.9996, respectively. (C)2018society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Strain sensor based on hollow microsphere Fabry-Perot cavity
    Monteiro, Catarina S.
    Silva, Susana O.
    Frazao, Orlando
    THIRD INTERNATIONAL CONFERENCE ON APPLICATIONS OF OPTICS AND PHOTONICS, 2017, 10453
  • [2] Cavity length dependence on strain sensitivity for Fabry-Perot sensors
    Rodrigues, Antonio V.
    Reis, Joao
    Martins, Antonio Jose M.
    Monteiro, Catarina S.
    Silva, Susana O.
    Caridade, Cristina M. R.
    Tavares, Sergio O.
    Frazao, Orlando
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2022, 64 (11) : 1951 - 1957
  • [3] Multiparameter Sensing of the Vernier Effect Based on Cascaded Sagnac and Fabry-Perot Interferometers
    Cheng, Ao
    Wang, Chaoqi
    Xu, Jiadong
    Dai, Shixun
    Zheng, Yu
    IEEE SENSORS JOURNAL, 2024, 24 (12) : 19090 - 19097
  • [4] Dislocated Fabry-Perot fiber cavity for strain measurement
    Liu, Jing
    Liu, Ye
    Wang, D. N.
    2017 16TH INTERNATIONAL CONFERENCE ON OPTICAL COMMUNICATIONS & NETWORKS (ICOCN 2017), 2017,
  • [5] High-Sensitivity Transverse-Load and Axial-Strain Sensor Based on Air-Bubble Fabry-Perot Cavity and Fiber Sagnac Loop Cascaded
    Zhang, Han
    Jiang, Chao
    Zhu, Xiping
    Hu, Jin
    Wang, Pei
    Li, Hong
    Sun, Simei
    Cao, Tingshui
    IEEE SENSORS JOURNAL, 2023, 23 (06) : 5795 - 5802
  • [6] Vernier Effect-Based Strain Sensor With Cascaded Fabry-Perot Interferometers
    Abbas, Lashari Ghulam
    IEEE SENSORS JOURNAL, 2020, 20 (16) : 9196 - 9201
  • [7] Simultaneous measurement of temperature and pressure with cascaded extrinsic Fabry-Perot interferometer and intrinsic Fabry-Perot interferometer sensors
    Zhang, Yinan
    Huang, Jie
    Lan, Xinwei
    Yuan, Lei
    Xiao, Hai
    OPTICAL ENGINEERING, 2014, 53 (06)
  • [8] Temperature Compensation of Fabry-Perot Optic Fiber Strain Sensors
    Lang, Li-Ying
    Gao, Feng
    SENSOR LETTERS, 2011, 9 (05) : 2058 - 2061
  • [9] Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor
    Chowdhury, Hasanur R.
    Wang, Xiaoli
    Han, Ming
    OPTICAL ENGINEERING, 2024, 63 (08)
  • [10] High temperature sensor based on an in-fibre Fabry-Perot cavity
    Schneller, Oliver
    Mathew, Jinesh
    MacPherson, William N.
    Maier, Robert R. J.
    23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157