A review on analytical methods with special reference to electroanalytical methods for the determination of some anticancer drugs in pharmaceutical and biological samples

被引:31
作者
Safaei, Mohadeseh [1 ]
Shishehbore, Masoud Reza [1 ]
机构
[1] Islamic Azad Univ, Dept Chem, Yazd Branch, Yazd, Iran
关键词
Anticancer; Chemotherapeutic drug; Analytical methods; Electroanalytical methods; Pharmaceutical samples; Biological samples; PERFORMANCE LIQUID-CHROMATOGRAPHY; SOLID-PHASE EXTRACTION; CARBON-PASTE ELECTRODE; TANDEM MASS-SPECTROMETRY; SENSITIVE ELECTROCHEMICAL DETERMINATION; MOLECULARLY IMPRINTED POLYMER; PENCIL GRAPHITE ELECTRODE; SCREEN-PRINTED ELECTRODE; REDUCED GRAPHENE OXIDE; HUMAN URINE SAMPLES;
D O I
10.1016/j.talanta.2021.122247
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It is widely accepted that cancer, the second leading cause of death, is a morbidity with big impacts on the global health. In the last few years, chemo-therapeutic treatment continually induces alone most lengthy consequents, which is extremely harmful for the physiological and psychological health of the patients. In the present research, we discuss the recent techniques for employed for extraction, and quantitative determination of such compounds in pharmaceutical, and biological specimens. In the frame of this information, this review aims to provide basic principles of chromatography, spectroscopy, and electroanalytical methods for the analysis of anticancer drugs published in the last three years. The review also describes the recent developments regarding enhancing the limit of detection (LOD), the linear dynamic range, and so forth. The results show that the LOD for the chromatographic techniques with the UV detector was obtained equaled over the range 2.0 ng mL(-1)-0.2 mu g mL(-1), whereas the LOD values for analysis by chromatographic technique with the mass spectrometry (MS) detector was found between 10.0 pg mL(-1)-0.002 mu g mL(-1). The biological fluids could be directly injected to capillary electrophoresis (CE) in cases where the medicine concentration is at the contents greater than mg L-1 or g L-1. Additionally, electrochemical detection of the anticancer drugs has been mainly conducted by the voltammetry techniques with diverse modified electrodes, and lower LODs were estimated between 3.0 ng mL 1-0.3 mu g mL(-1). It is safe to say that the analyses of anticancer drugs can be achieved by employing a plethora of techniques such as electroanalytical, spectroscopy, and chromatography techniques.
引用
收藏
页数:33
相关论文
共 231 条
  • [1] Bio-dispersive liquid liquid microextraction based on nano rhamnolipid aggregates combined with molecularly imprinted-solid phase extraction for selective determination of paracetamol in human urine samples followed by HPLC
    Abbasi, Shahryar
    Haeri, Seyed Ammar
    Sajjadifar, Sami
    [J]. MICROCHEMICAL JOURNAL, 2019, 146 : 106 - 114
  • [2] Eco-Friendly Fabricated Electrochemical Sensor Using Red Cabbage Extract for Electrochemical Determination of Dacarbazine with the Aid of Factorial Design Approach
    Abdel-aal, Fatma A. M.
    Ali, Marwa F. B.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2017, 164 (14) : H1053 - H1063
  • [3] Versatile Sensor Modified with Gold Nanoparticles Carbon Paste Electrode for Anodic Stripping Determination of Brexpiprazole: A Voltammetric Study
    Abdel-Raoof, Ahmed M.
    El-Shal, Manal A.
    Said, Ragab A. M.
    Abostate, Mona H.
    Morshedy, Samir
    Emara, Mohamed S.
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (12) : B948 - B955
  • [4] Ultrasonic-assisted dispersive micro solid-phase extraction based on melamine-phytate supermolecular aggregate as a novel bio-inspired magnetic sorbent for preconcentration of anticancer drugs in biological samples prior to HPLC-UV analysis
    Adlnasab, Laleh
    Ezoddin, Maryam
    Shojaei, Rouh Allah
    Aryanasab, Fezzeh
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1095 : 226 - 234
  • [5] A novel voltammetric sensor based on palladium nanoparticles/carbon nanofibers/ionic liquid modified carbon paste electrode for sensitive determination of anti-cancer drug pemetrexed
    Afzali, Moslem
    Mostafavi, Ali
    Nekooie, Reyhaneh
    Jahromi, Zahra
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2019, 282 : 456 - 465
  • [6] GC-MS analysis of ethanol extract from areal parts of Nepeta deflersiana and its anticancer and antimicrobial efficacies
    Ahmad, Irfan
    Irfan, Safia
    Dera, Ayed A.
    Zaman, Gaffar S.
    Chandramoorthy, Harish C.
    Mir, Mushtaq Ahmad
    Rajagopalan, Prasanna
    [J]. BIOLOGIA, 2020, 75 (10) : 1739 - 1750
  • [7] Development and validation of LC-MS/MS assay for the simultaneous determination of methotrexate, 6-mercaptopurine and its active metabolite 6-thioguanine in plasma of children with acute lymphoblastic leukemia: Correlation with genetic polymorphism
    Al-Ghobashy, Medhat A.
    Hassan, Said A.
    Abdelaziz, Doaa H.
    Elhosseiny, Noha M.
    Sabry, Nirmeen A.
    Attia, Ahmed S.
    El-Sayed, Manal H.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1038 : 88 - 94
  • [8] Evaluation of Chemotherapy Drugs Carboplatin and Temozolamide in Pharmaceutical Formulations and Biosamples via Capillary Zone Electrophoresis Approach
    Alarfaj, Nawal A.
    El-Tohamy, Maha F.
    [J]. INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2018, 13 (05): : 4512 - 4525
  • [9] Simultaneous determination of doxorubicin and dasatinib as two breast anticancer drugs uses an amplified sensor with ionic liquid and ZnO nanoparticle
    Alavi-Tabari, Seyed A. R.
    Khalilzadeh, Mohammad A.
    Karimi-Maleh, Hassan
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 811 : 84 - 88
  • [10] An amplified platform nanostructure sensor for the analysis of epirubicin in the presence of topotecan as two important chemotherapy drugs for breast cancer therapy
    Alavi-Tabari, Seyed A. R.
    Khalilzadeh, Mohammad A.
    Karimi-Maleh, Hassan
    Zareyee, Daryoush
    [J]. NEW JOURNAL OF CHEMISTRY, 2018, 42 (05) : 3828 - 3832