Polycyclic aromatic hydrocarbons in ambient air in the Philippines derived from passive sampler with polyurethane foam disk
被引:42
作者:
Santiago, Evangeline C.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Philippines, Nat Sci Res Inst, Res & Analyt Serv Lab, Quezon City 1101, PhilippinesUniv Philippines, Nat Sci Res Inst, Res & Analyt Serv Lab, Quezon City 1101, Philippines
Santiago, Evangeline C.
[1
]
Cayetano, Mylene G.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Philippines, Nat Sci Res Inst, Res & Analyt Serv Lab, Quezon City 1101, PhilippinesUniv Philippines, Nat Sci Res Inst, Res & Analyt Serv Lab, Quezon City 1101, Philippines
Cayetano, Mylene G.
[1
]
机构:
[1] Univ Philippines, Nat Sci Res Inst, Res & Analyt Serv Lab, Quezon City 1101, Philippines
passive air sampling;
polycyclic aromatic hydrocarbons;
polyurethane foam disk;
D O I:
10.1016/j.atmosenv.2007.01.021
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
Passive samplers with polyurethane disks (PUF) were applied in the determination of the concentration of polycyclic aromatic hydrocarbons (PAHs) in ambient air in six residential areas in the Philippines during four simultaneous sampling periods. The uptake profiles of PAHs were determined at one site during one sampling period. Most of the PAHs that were detected in air at concentrations that were significantly higher than their analytical detection limits exhibited a linear uptake trend on the PUF disk. The linear uptake profiles of some high molecular weight (HMW) PAHs were not established and this is attributed to the low concentration of the compounds in air in the gaseous phase. The retention concentrations of phenanthrene-d-10 were determined after depuration in four sampling sites during two sampling periods. The sampling rate for phenanthrene-d-10 was calculated at the linear phase of the uptake using the k(A) derived from depuration experiments and the relationship of kA and sampling rate which was established in a previous passive sampling study. The average sampling rate obtained for phenanthrene d-10 (2.94 +/- 0.69 m(3) d(-1)) was applied for derivation of the concentrations of the PAHs in the field samples. The passive sampler with PUF disk and short integration time of 42-56 days is applicable for the derivation of the concentrations of PAHs in ambient air in the Philippines. The concentrations of the organic pollutants derived from the passive sampler showed variability for the six residential areas; reflecting the influence of possible sources of emission of the pollutants at the sites at the different sampling periods. The weather conditions, including the occurrence of a tropical cyclone, increased rainfall and high-relative humidity during the rainy season, had an influence on the concentrations of PAHs derived by the passive sampler. (C) 2007 Elsevier Ltd. All rights reserved.