A model of respiratory airway motion for real-time tracking of an ultrathin bronchoscope

被引:6
作者
Soper, Timothy D. [1 ]
Haynor, David R. [1 ,2 ]
Glenny, Robb W. [1 ,3 ]
Seibel, Eric J. [1 ,4 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] Univ Washington, Dept Radiol, Seattle, WA 98195 USA
[3] Univ Washington, Pulmonary & Critical Care Med, Seattle, WA 98195 USA
[4] Univ Washington, Mech Engn, Seattle, WA 98195 USA
来源
MEDICAL IMAGING 2007: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES | 2007年 / 6511卷
关键词
registration; lung; airways; bronchoscopy; respiration; breathing; CT;
D O I
10.1117/12.710150
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deformable registration of chest CT scans taken of a subject at various phases of respiration provide a direct measure of the spatially varying displacements that occur in the lung due to breathing. This respiratory motion was studied as part of the development of a CT-based guidance system for a new electromagnetically tracked ultrathin bronchoscope. Fifteen scans of an anesthesized pig were acquired at five distinct lung pressures between full expiration to full inspiration. Deformation fields were computed by non-rigid registration using symmetric "demons" forces followed by Gaussian regularization in a multi-resolution framework. Variants of the registration scheme were tested including: initial histogram matching of input images, degree of field smoothing during regularization, and applying an adaptive smoothing method that weights elements of the smoothing kernel by the magnitude of the image gradient. Registration quality was quantified and compared using inverse and transitive consistency metrics. After optimizing the algorithm parameters, deformation fields were computed by registering each image in the set to a baseline image. Registration of the baseline image at full inspiration to an image at full expiration produced the maximum deformation. Two hypotheses were made: first, that each deformation could be modeled as a mathematical sub-multiple of the maximum deformation, and second, that the deformation scales linearly with respiratory pressure. The discrepancy between the deformation measured by image registration and that predicted by the linear model was 1.25 mm. on average. At maximum deformation, this motion compensation constitutes an 87% reduction in respiration-induced localization error.
引用
收藏
页数:12
相关论文
共 13 条
  • [1] Bronchoscopic Biopsy of Peripheral Lung Lesions Under Electromagnetic Guidance
    Becker, Heinrich D.
    Herth, Felix
    Ernst, Armin
    Schwarz, Yehuda
    [J]. JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2005, 12 (01) : 9 - 13
  • [2] Comparison of 3D dense deformable registration methods for breath-hold reproducibility study in radiotherapy
    Boldea, V
    Sarrut, D
    Carrie, C
    [J]. Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 222 - 230
  • [3] Invertibility and transitivity analysis for nonrigid image registration
    Christensen, GE
    Johnson, HJ
    [J]. JOURNAL OF ELECTRONIC IMAGING, 2003, 12 (01) : 106 - 117
  • [4] Automatic lung segmentation for accurate quantitation of volumetric X-ray CT images
    Hu, SY
    Hoffman, EA
    Reinhardt, JM
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (06) : 490 - 498
  • [5] POPA T, 2006, SPIE MED IMAGING 200, V6141
  • [6] Electromagnetic navigation during flexible bronchoscopy
    Schwarz, Y
    Mehta, AC
    Ernst, A
    Herth, F
    Engel, A
    Besser, D
    Becker, HD
    [J]. RESPIRATION, 2003, 70 (05) : 516 - 522
  • [7] SEIBEL E, 2006, SPIE PROGR BIOMEDICA, V6083, P9
  • [8] Real-time bronchoscope tip localization enables three-dimensional CT image guidance for transbronchial needle aspiration in swine
    Solomon, SB
    White, P
    Acker, DE
    Strandberg, J
    Venbrux, AC
    [J]. CHEST, 1998, 114 (05) : 1405 - 1410
  • [9] Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor - A comparison of two image registration methods
    Solomon, SB
    White, P
    Wiener, CM
    Orens, JB
    Wang, KP
    [J]. CHEST, 2000, 118 (06) : 1783 - 1787
  • [10] THIRION J, 1995, THESIS I NATL RECHER