Different schematic eyes and their accuracy to the in vivo eye: A quantitative comparison study

被引:33
作者
de Almeida, Marina Storani [1 ]
Carvalho, Luis Alberto
机构
[1] Univ Fed Sao Carlos, BR-13560250 Sao Carlos, SP, Brazil
[2] Inst Fis Sao Carlos, IFSC USP, Grp Opt, BR-13560250 Sao Carlos, SP, Brazil
关键词
eye model; schematic eye; ray tracing; optical aberrations;
D O I
10.1590/S0103-97332007000300008
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Current ophthalmic technology allows the manipulation of eye components, such as anterior comea and lens, of the human eye with a considerable precision and customization. This technology opens up the possibility of exploiting some characteristics of the eye in order to improve the methods of correcting optical aberrations. Moreover, product development and research for the eye-care professional has reached very high standards, since there is nowadays software available to design and simulate practically any mechanical or optical characteristic of the product, even before it is thrown into production line. Although quite similar in the general form, different human eye models simulate the image formation by considering different property combinations in the constitutive elements of the eye structure (such as refraction index and surface curvatures), producing retinal images that resemble very closely those of the biological eye. Using optical design software, we have implemented a simulation of 5 well-known schematic eyes available in the literature. These models were the Helmholtz-Laurance, Gullstrand, Emsley, Greivenkamp and Liou & Brennan. The optical performance of these different models was compared using different quantitative optical quality parameters. The model of Liou and Brennan, contains features of the biological eye that were not considered in previous models, as the distribution of a gradient refraction index and a decentered pupil. Furthermore, it has great reliability since it takes into account the mean value of empirical measurements of the in vivo eye in order to define size and parameters such as anterior and posterior curvature of comea, lens, axial length, etc. Comparisons between the MTF (Modulation Transfer Function), spot diagrams and ray fan showed the difference in image quality between eye models, and the Strehl Ratio was also used as a parameter of comparison. A careful comparison between the different models showed that the first four schematic eyes have better optical quality than what is expected for the general and healthy emmetropic in vivo eye. Liou and Brennan schematic eye is the one that most closely resembles the in vivo biological eye. Therefore, in applications, such as research or product development for customized vision correction, which must consider optical properties intrinsic to the biological eye, we recommend this latter model; for applications that do not require refraction-limited performance, most of the other models should be a good approximation.
引用
收藏
页码:378 / 387
页数:10
相关论文
共 32 条
  • [1] ALPERN M, 1978, HDB OPTICS
  • [2] [Anonymous], 1998, OPTICS VISION
  • [3] Born M., 1999, PRINCIPLES OPTICS EL
  • [4] OPTICAL QUALITY OF HUMAN EYE
    CAMPBELL, FW
    GUBISCH, RW
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1966, 186 (03): : 558 - +
  • [5] Preliminary tests and construction of a computerized quantitative surgical keratometer
    Carvalho, L
    Tonissi, SA
    Castro, JC
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (06) : 821 - 826
  • [6] On the absolute accuracy of Zernike Polynomials to characterize the corneal surface and the optical aberrations of the human eye
    Carvalho, LA
    [J]. Saratov Fall Meeting 2004: Coherent Optics of Ordered and Random Media V, 2005, 5772 : 181 - 192
  • [7] A simple and effective algorithm for detection of arbitrary Hartmann-Shack patterns
    Carvalho, LA
    [J]. JOURNAL OF BIOMEDICAL INFORMATICS, 2004, 37 (01) : 1 - 9
  • [8] Videokeratoscopes for dioptric power measurement during surgery
    Carvalho, LA
    Stefani, M
    Romao, AC
    Carvalho, L
    de Castro, JC
    Tonissi, S
    Schor, P
    Chamon, W
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (11) : 2006 - 2016
  • [9] CARVALHO LA, 2003, REV FISICA INSTRUMEN, V16, P24
  • [10] CARVALHO LA, 2003, BRAZ J PHYS, V33, P140